{"path":"01-Documentation/Inverters/SEW/adjuntos/Pasted image 20240925131406.png","text":"Configuring the drive behavior at standstill (FCB 02, FCB 13, FCB 14) The parameter Behavior at standstill defines the drive behavior in case the drive enable is revoked and the motor is at standstil (path: Functions > Drive functions > FCB 02 Stop default). This parameter is effective when the function blocks FCB 02, FCB 13 and FCB 14 are active. The following table lists the drive behavior after motor standstill: Behavior at motor standstill Index Parameter Setting Motori E : °\":gld Effect on the DynaStop D hol the motor shaft control 8563.1 Behavior at standstill Drive energized (brake DynaStop® Position hold control The motor shaft is (Path: Functions > released is deactivated active regulated to Drive functions > / DynaStop® deactivated) rotational speed = FCB 02 Stop default) 0\" by the motor. Drive not energized DynaStop® The motor is The motion of the (brake applied / is activated disconnected from motor shaft is DynaStop® activated) the current supply. retarded by DynaStop®. Drive not energized DynaStop® The motor is The motor shaft can (without brake/DynaStop®) is deactivated disconnected from rotate freely. the current supply.","libVersion":"0.3.2","langs":"eng+ita"}