### **PROBLEM:** Need to Rephase
#### **BROKEN DOWN:**
If both sides are not in phase, as shown in the next picture, they must be rephased.
#### **POSSIBLE CAUSE OR PROCEDURE FOR FAULT DETECTION:**
After changing the belts or another mechanical component, the phase between both endless screws must be checked.
#### **SOLUTION:**
1. Remove both endless screws.
2. Tension the belt so it is ready to run.
3. Rotate the shaft coupling to the phase mark as shown in the picture.
4. Loosen the bolts to allow the rephasing of the shaft coupling.
5. Rotate the loose shaft to match the phase mark.
6. Both shafts must match the phase mark. If necessary, it's possible to jump one hole.
7. Tighten the bolts.
8. Reinstall the screws.
##### IMAGES:
***
![[Pasted image 20240712131317.png|500]]
( image 1 ) - Phase Marks on the coupling shaft
![[Pasted image 20240712131243.png]]
( image 2 ) - Bolts to loose the coupling shaft