{"path":"01-Documentation/SIEMENS & WINCC/PLC Siemens/adjuntos/Specs 6ES75152AN030AB0_datasheet_en.pdf","text":"Data sheet 6ES7515-2AN03-0AB0 SIMATIC S7-1500, CPU 1515-2 PN, central processing unit with work memory 1 MB for program and 4.5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 6 ns bit performance, SIMATIC Memory Card required - - approvals and certificates according to entry 109817466 at support.industry.siemens.com to be considered! - - General information Product type designation CPU 1515-2 PN HW functional status FS04 Firmware version V3.1 ● FW update possible Yes Product function ● I&M data Yes; I&M0 to I&M3 ● Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central) ● SysLog Yes Engineering with ● STEP 7 TIA Portal configurable/integrated from version V19 (FW V3.1) / V18 (FW V3.0) or higher; with older TIA Portal versions configurable as 6ES7515-2AM02-0AB0 Configuration control via dataset Yes Display Screen diagonal [cm] 6.1 cm Control elements Number of keys 8 Mode buttons 2 Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Mains buffering ● Mains/voltage failure stored energy time 5 ms ● Repeat rate, min. 1/s Input current Current consumption (rated value) 0.65 A Current consumption, max. 1.03 A Inrush current, max. 1.15 A; Rated value I²t 0.6 A²·s Power Infeed power to the backplane bus 12 W Power consumption from the backplane bus (balanced) 6.2 W Power loss 6ES75152AN030AB0 Page 1/9 11/11/2024 Subject to change without notice © Copyright Siemens Power loss, typ. 3.6 W Memory Number of slots for SIMATIC memory card 1 SIMATIC memory card required Yes Work memory ● integrated (for program) 1 Mbyte ● integrated (for data) 4.5 Mbyte Load memory ● Plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup ● maintenance-free Yes CPU processing times for bit operations, typ. 6 ns for word operations, typ. 7 ns for fixed point arithmetic, typ. 9 ns for floating point arithmetic, typ. 37 ns CPU-blocks Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs DB ● Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 ● Size, max. 4.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB FB ● Number range 0 ... 65 535 ● Size, max. 1 Mbyte FC ● Number range 0 ... 65 535 ● Size, max. 1 Mbyte OB ● Size, max. 1 Mbyte ● Number of free cycle OBs 100 ● Number of time alarm OBs 20 ● Number of delay alarm OBs 20 ● Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs ● Number of process alarm OBs 50 ● Number of DPV1 alarm OBs 3 ● Number of isochronous mode OBs 2 ● Number of technology synchronous alarm OBs 2 ● Number of startup OBs 100 ● Number of asynchronous error OBs 4 ● Number of synchronous error OBs 2 ● Number of diagnostic alarm OBs 1 Nesting depth ● per priority class 24 Counters, timers and their retentivity S7 counter ● Number 2 048 Retentivity — adjustable Yes IEC counter ● Number Any (only limited by the main memory) Retentivity — adjustable Yes S7 times ● Number 2 048 Retentivity — adjustable Yes IEC timer ● Number Any (only limited by the main memory) Retentivity — adjustable Yes 6ES75152AN030AB0 Page 2/9 11/11/2024 Subject to change without notice © Copyright Siemens Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB Extended retentive data area (incl. timers, counters, flags), max. 4.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF Flag ● Size, max. 16 kbyte ● Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte Data blocks ● Retentivity adjustable Yes ● Retentivity preset No Local data ● per priority class, max. 64 kbyte; max. 16 KB per block Address area Number of IO modules 8 192; max. number of modules / submodules I/O address area ● Inputs 32 kbyte; All inputs are in the process image ● Outputs 32 kbyte; All outputs are in the process image per integrated IO subsystem — Inputs (volume) 8 kbyte — Outputs (volume) 8 kbyte per CM/CP — Inputs (volume) 8 kbyte — Outputs (volume) 8 kbyte Subprocess images ● Number of subprocess images, max. 32 Hardware configuration Number of distributed IO systems 64; A distributed I/O system is characterized not only by the integration of distributed I/O via PROFINET or PROFIBUS communication modules, but also by the connection of I/O via AS-i master modules or links (e.g. IE/PB-Link) Number of DP masters ● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total Number of IO Controllers ● integrated 2 ● Via CM 8; A maximum of 8 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total Rack ● Modules per rack, max. 32; CPU + 31 modules ● Number of lines, max. 1 PtP CM ● Number of PtP CMs the number of connectable PtP CMs is only limited by the number of available slots Time of day Clock ● Type Hardware clock ● Backup time 6 wk; At 40 °C ambient temperature, typically ● Deviation per day, max. 10 s; Typ.: 2 s Operating hours counter ● Number 16 Clock synchronization ● supported Yes ● to DP, master Yes; via PROFIBUS CM / CP ● on DP, device Yes; via PROFIBUS CM / CP ● in AS, master Yes ● in AS, device Yes ● on Ethernet via NTP Yes Interfaces Number of PROFINET interfaces 2 1. Interface Interface types ● RJ 45 (Ethernet) Yes; X1 ● Number of ports 2 6ES75152AN030AB0 Page 3/9 11/11/2024 Subject to change without notice © Copyright Siemens ● integrated switch Yes Protocols ● IP protocol Yes; IPv4 ● PROFINET IO Controller Yes ● PROFINET IO Device Yes ● SIMATIC communication Yes ● Open IE communication Yes; Optionally also encrypted ● Web server Yes ● Media redundancy Yes PROFINET IO Controller Services — Isochronous mode Yes — Direct data exchange Yes; Requirement: IRT and isochronous mode (MRPD optional) — IRT Yes — PROFIenergy Yes; per user program — Prioritized startup Yes; Max. 32 PROFINET devices — Number of connectable IO Devices, max. 256; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET — Of which IO devices with IRT, max. 64 — Number of connectable IO Devices for RT, max. 256 — of which in line, max. 256 — Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces — Number of IO Devices per tool, max. 8 — Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data — PROFINET Security Class 1 Update time for IRT — for send cycle of 250 µs 250 μs to 4 ms; Note: In the case of IRT with isochronous mode, the minimum update time of 375 µs of the isochronous OB is decisive — for send cycle of 500 µs 500 µs to 8 ms — for send cycle of 1 ms 1 ms to 16 ms — for send cycle of 2 ms 2 ms to 32 ms — for send cycle of 4 ms 4 ms to 64 ms — With IRT and parameterization of \"odd\" send cycles Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs) Update time for RT — for send cycle of 250 µs 250 µs to 128 ms — for send cycle of 500 µs 500 µs to 256 ms — for send cycle of 1 ms 1 ms to 512 ms — for send cycle of 2 ms 2 ms to 512 ms — for send cycle of 4 ms 4 ms to 512 ms PROFINET IO Device Services — Isochronous mode No — IRT Yes — PROFIenergy Yes; per user program — Shared device Yes — Number of IO Controllers with shared device, max. 4 — activation/deactivation of I-devices Yes; per user program — Asset management record Yes; per user program — PROFINET Security Class SNMP Configuration and DCP Read Only 2. Interface Interface types ● RJ 45 (Ethernet) Yes; X2 ● Number of ports 1 ● integrated switch No Protocols ● IP protocol Yes; IPv4 ● PROFINET IO Controller Yes ● PROFINET IO Device Yes 6ES75152AN030AB0 Page 4/9 11/11/2024 Subject to change without notice © Copyright Siemens ● SIMATIC communication Yes ● Open IE communication Yes; Optionally also encrypted ● Web server Yes ● Media redundancy No PROFINET IO Controller Services — Isochronous mode No — Direct data exchange No — IRT No — PROFIenergy Yes; per user program — Prioritized startup No — Number of connectable IO Devices, max. 32; In total, up to 1 000 distributed I/O devices can be connected via AS-i, PROFIBUS or PROFINET — Number of connectable IO Devices for RT, max. 32 — of which in line, max. 32 — Number of IO Devices that can be simultaneously activated/deactivated, max. 8; in total across all interfaces — Number of IO Devices per tool, max. 8 — Updating times The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data — PROFINET Security Class 1 Update time for RT — for send cycle of 1 ms 1 ms to 512 ms PROFINET IO Device Services — Isochronous mode No — IRT No — PROFIenergy Yes; per user program — Prioritized startup No — Shared device Yes — Number of IO Controllers with shared device, max. 4 — activation/deactivation of I-devices Yes; per user program — Asset management record Yes; per user program — PROFINET Security Class SNMP Configuration and DCP Read Only Interface types RJ 45 (Ethernet) ● 100 Mbps Yes ● Autonegotiation Yes ● Autocrossing Yes ● Industrial Ethernet status LED Yes Protocols PROFIsafe No Number of connections ● Number of connections, max. 256; via integrated interfaces of the CPU and connected CPs / CMs ● Number of connections reserved for ES/HMI/web 10 ● Number of connections via integrated interfaces 128 ● Number of S7 routing paths 16 Redundancy mode ● H-Sync forwarding Yes Media redundancy — Media redundancy only via 1st interface (X1) — MRP Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client — MRP interconnection, supported Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 — MRPD Yes; Requirement: IRT — Switchover time on line break, typ. 200 ms; For MRP, bumpless for MRPD — Number of stations in the ring, max. 50 SIMATIC communication ● PG/OP communication Yes; encryption with TLS V1.3 pre-selected ● S7 routing Yes ● Data record routing Yes 6ES75152AN030AB0 Page 5/9 11/11/2024 Subject to change without notice © Copyright Siemens ● S7 communication, as server Yes ● S7 communication, as client Yes ● User data per job, max. See online help (S7 communication, user data size) Open IE communication ● TCP/IP Yes — Data length, max. 64 kbyte — several passive connections per port, supported Yes ● ISO-on-TCP (RFC1006) Yes — Data length, max. 64 kbyte ● UDP Yes — Data length, max. 2 kbyte; 1 472 bytes for UDP broadcast — UDP multicast Yes; max. 118 multicast circuits ● DHCP Yes ● DNS Yes ● SNMP Yes ● DCP Yes ● LLDP Yes ● Encryption Yes; Optional Web server ● HTTP Yes; Standard and user pages ● HTTPS Yes; Standard and user pages ● web API — Number of sessions, max. 100 — number of simultaneous HTTP calls, max. 4 — HTTP request body, max. 131 072 byte OPC UA ● Runtime license required Yes; \"Medium\" license required ● OPC UA Client Yes; Data Access (registered Read/Write), Method Call — Application authentication Yes — Security policies Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 — User authentication \"anonymous\" or by user name & password — Number of connections, max. 10 — Number of nodes of the client interfaces, recommended max. 2 000 — Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. 300 — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. 20 — Number of elements for one call of OPC_UA_MethodGetHandleList, max. 100 — Number of simultaneous calls of the client instructions for session management, per connection, max. 1 — Number of simultaneous calls of the client instructions for data access, per connection, max. 5 — Number of registerable nodes, max. 5 000 — Number of registerable method calls of OPC_UA_MethodCall, max. 100 — Number of inputs/outputs when calling OPC_UA_MethodCall, max. 20 ● OPC UA Server Yes; Data Access (Read, Write, Subscribe), Method Call, Alarms & Condition (A&C), Custom Address Space — Application authentication Yes — Security policies available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss — User authentication \"anonymous\" or by user name & password — GDS support (certificate management) Yes — Number of sessions, max. 48 — Number of accessible variables, max. 100 000 — Number of registerable nodes, max. 20 000 — Number of subscriptions per session, max. 50 — Sampling interval, min. 100 ms — Publishing interval, min. 100 ms 6ES75152AN030AB0 Page 6/9 11/11/2024 Subject to change without notice © Copyright Siemens — Number of server methods, max. 50 — Number of inputs/outputs per server method, max. 20 — Number of monitored items, recommended max. 4 000; for 1 s sampling interval and 1 s send interval — Number of server interfaces, max. 10 of each \"Server interfaces\" / \"Companion specification\" type and 20 of the type \"Reference namespace\" — Number of nodes for user-defined server interfaces, max. 30 000 ● Alarms and Conditions Yes — Number of program alarms 200 — Number of alarms for system diagnostics 100 Further protocols ● MODBUS Yes; MODBUS TCP S7 message functions Number of login stations for message functions, max. 64 number of subscriptions, max. 500 number of tags/attributes for subscriptions, max. 8 000 Program alarms Yes Number of configurable program messages, max. 10 000; Program messages are generated by the \"Program_Alarm\" block, ProDiag or GRAPH Number of loadable program messages in RUN, max. 10 000 Number of simultaneously active program alarms ● Number of program alarms 1 000 ● Number of alarms for system diagnostics 200 ● Number of alarms for motion technology objects 160 Test commissioning functions Joint commission (Team Engineering) Yes; Parallel online access possible for up to 8 engineering systems Status block Yes; Up to 8 simultaneously (in total across all ES clients) Single step No Number of breakpoints 8 Profiling Yes Status/control ● Status/control variable Yes ● Variables Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters ● Number of variables, max. — of which status variables, max. 200; per job — of which control variables, max. 200; per job Forcing ● Forcing Yes ● Forcing, variables Peripheral inputs/outputs ● Number of variables, max. 200 Diagnostic buffer ● present Yes ● Number of entries, max. 3 200 — of which powerfail-proof 500 Traces ● Number of configurable Traces 4 ● Memory size per trace, max. 512 kbyte Interrupts/diagnostics/status information Diagnostics indication LED ● RUN/STOP LED Yes ● ERROR LED Yes ● MAINT LED Yes ● STOP ACTIVE LED Yes ● Connection display LINK TX/RX Yes Supported technology objects Motion Control Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool ● Number of available Motion Control resources for technology objects 2 400 ● Required Motion Control resources — per speed-controlled axis 40 — per positioning axis 80 6ES75152AN030AB0 Page 7/9 11/11/2024 Subject to change without notice © Copyright Siemens — per synchronous axis 160 — per external encoder 80 — per output cam 20 — per cam track 160 — per probe 40 ● Positioning axis — Number of positioning axes at motion control cycle of 4 ms (typical value) 11 — Number of positioning axes at motion control cycle of 8 ms (typical value) 20 Controller ● PID_Compact Yes; Universal PID controller with integrated optimization ● PID_3Step Yes; PID controller with integrated optimization for valves ● PID-Temp Yes; PID controller with integrated optimization for temperature Counting and measuring ● High-speed counter Yes Standards, approvals, certificates Ecological footprint ● environmental product declaration Yes Global warming potential — global warming potential, (total) [CO2 eq] 100 kg — global warming potential, (during production) [CO2 eq] 25.8 kg — global warming potential, (during operation) [CO2 eq] 75.2 kg — global warming potential, (after end of life cycle) [CO2 eq] -0.83 kg Ambient conditions Ambient temperature during operation ● horizontal installation, min. -30 °C; No condensation ● horizontal installation, max. 60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off ● vertical installation, min. -30 °C; No condensation ● vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off Ambient temperature during storage/transportation ● min. -40 °C ● max. 70 °C Altitude during operation relating to sea level ● Installation altitude above sea level, max. 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual configuration / header configuration / programming / header Programming language — LAD Yes — FBD Yes — STL Yes — SCL Yes — CFC Yes — GRAPH Yes Know-how protection ● User program protection/password protection Yes ● Copy protection Yes ● Block protection Yes Access protection ● protection of confidential configuration data Yes ● Password for display Yes ● Protection level: Write protection Yes ● Protection level: Read/write protection Yes ● Protection level: Write protection for Failsafe No ● Protection level: Complete protection Yes ● User administration Yes; device-wide programming / cycle time monitoring / header ● lower limit adjustable minimum cycle time 6ES75152AN030AB0 Page 8/9 11/11/2024 Subject to change without notice © Copyright Siemens ● upper limit adjustable maximum cycle time Dimensions Width 70 mm Height 147 mm Depth 129 mm Weights Weight, approx. 456 g last modified: 10/9/2024 6ES75152AN030AB0 Page 9/9 11/11/2024 Subject to change without notice © Copyright Siemens","libVersion":"0.3.2","langs":""}