```pascal // Block Type: FB // Block Number: 1787 // Original Network Languages: LAD FUNCTION_BLOCK "BlenderPIDCtrl_Monitor" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_INPUT i_Value : Real; i_Cols : Int; i_Rows : Int; END_VAR VAR_OUTPUT MeanValue : Real; Variance : Real; Std_Deviation : Real; END_VAR VAR_STAT Water_Stat : "Statistical_Analisys"; Syrup_Stat : "Statistical_Analisys"; Carbo_CO2_Stat : "Statistical_Analisys"; Gas2_Stat : "Statistical_Analisys"; END_VAR BEGIN // Network 1: Water Statistic analisys (Original Language: LAD) "Water_Stat"(i_Cols := 14, i_Rows := 1, i_Value := "HMI_PID"."RMM301"."Out"); // Network 2: Water Values (Original Language: LAD) "HMI_Service"."PID_Monitoring"."_RMM301_MeanValue" := "Blender_Variables"."gWaterStat_MeanValue"; "HMI_Service"."PID_Monitoring"."_RMM301_Variance" := "Blender_Variables"."gWaterStat_Variance"; "HMI_Service"."PID_Monitoring"."_RMM301_StdDev" := "Blender_Variables"."gWaterStat_DevStd"; // Network 3: Water PID Controlling Ok (Original Language: LAD) // Network 3 did not produce printable SCL code. // Network 4: Syrup Statistic analisys (Original Language: LAD) "Syrup_Stat"(i_Cols := 14, i_Rows := 1, i_Value := "HMI_PID"."RMP302"."Out"); // Network 5: Syrup Values (Original Language: LAD) "HMI_Service"."PID_Monitoring"."_RMP302_MeanValue" := "Blender_Variables"."gSyrupStat_MeanValue"; "HMI_Service"."PID_Monitoring"."_RMP302_Variance" := "Blender_Variables"."gSyrupStat_Variance"; "HMI_Service"."PID_Monitoring"."_RMP302_StdDev" := "Blender_Variables"."gSyrupStat_DevStd"; // Network 6: Syrup PID Controlling Ok (Original Language: LAD) // Network 6 did not produce printable SCL code. // Network 7: Co2 Statistic analisys (Original Language: LAD) "Carbo_CO2_Stat"(i_Cols := 12, i_Rows := 1, i_Value := "HMI_PID"."RMM303"."Out"); // Network 8: Co2 Values (Original Language: LAD) "HMI_Service"."PID_Monitoring"."_RMM303_MeanValue" := "Blender_Variables"."gCarboCO2Stat_MeanValue"; "HMI_Service"."PID_Monitoring"."_RMM303_Variance" := "Blender_Variables"."gCarboCO2Stat_Variance"; "HMI_Service"."PID_Monitoring"."_RMM303_StdDev" := "Blender_Variables"."gCarboCO2Stat_DevStd"; // Network 9: CO2 PID Controlling Ok (Original Language: LAD) // Network 9 did not produce printable SCL code. // Network 10: Gas2 Statistic analisys (Original Language: LAD) "Gas2_Stat"(i_Cols := 12, i_Rows := 1, i_Value := "HMI_PID"."RMM304"."Out"); // Network 11: Gas2 Values (Original Language: LAD) "HMI_Service"."PID_Monitoring"."_RMM304_MeanValue" := "Blender_Variables"."gGAS2Stat_MeanValue"; "HMI_Service"."PID_Monitoring"."_RMM304_Variance" := "Blender_Variables"."gGAS2Stat_Variance"; "HMI_Service"."PID_Monitoring"."_RMM304_StdDev" := "Blender_Variables"."gGAS2Stat_DevStd"; // Network 12: Gas2 PID Controlling Ok (Original Language: LAD) // Network 12 did not produce printable SCL code. END_FUNCTION_BLOCK ```