```pascal // Block Type: FC // Block Number: 2037 // Original Network Languages: STL FUNCTION "BlenderCtrl_ManualActive" : Void { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_TEMP Dim_HMI_Device : Int; PDim_HMI_Device : DWord; Dim_HMI_PID : Int; PDim_HMI_PID : DWord; END_VAR BEGIN // Network 1: Set manual active (Original Language: STL) // DEVICE // --- BEGIN STL Network 1 --- SET R "HMI_Alarms".gH_Message[3] // --- END STL Network 1 --- // Network 2: (Original Language: STL) // --- BEGIN STL Network 2 --- AUF "HMI_Device" L_DBLG T "Dim_HMI_Device" L P#0.0 L "Dim_HMI_Device" SLD 3 ADD_D T "PDim_HMI_Device" L P#0.0 LAR1_ACCU1 M100: NOP_0 AUF "HMI_Device" A DBX[AR1,P#0.7] AN DBX[AR1,P#0.0] S "HMI_Alarms".gH_Message[3] ADDAR1 P#2.0 TAR1_ACCU1 L "PDim_HMI_Device" LT_D JC M100 // --- END STL Network 2 --- // Network 3: (Original Language: STL) // --- BEGIN STL Network 3 --- AUF "HMI_PID" L_DBLG T "Dim_HMI_PID" L P#0.0 L "Dim_HMI_PID" SLD 3 ADD_D T "PDim_HMI_PID" L P#0.0 LAR1_ACCU1 M101: NOP_0 AUF "HMI_PID" A DBX[AR1,P#0.7] A_BRACK A DBX[AR1,P#2.0] O DBX[AR1,P#3.0] BRACKET S "HMI_Alarms".gH_Message[3] ADDAR1 P#76.0 TAR1_ACCU1 L "PDim_HMI_PID" LT_D JC M101 // --- END STL Network 3 --- END_FUNCTION ```