```pascal // Block Type: GlobalDB // Block Number: 964 DATA_BLOCK "Filler_Head_Variables" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR Sensor_Head_PV : Real := 0.0; TM301_Height : Real := 1002.496; DiffSensor_Height : Real := 518.0; Head_PID_Manual_Value : Real := 5.741542; FillerCentrifugalHead : Real := 0.0; TotalPressLoss : Real := 1.7; Filler_Speed : Real := 0.0; Filler_Temperature : Real := 15.7; Prod_Flow : Real := 0.0; Prod_FlowEstimated : Real := 0.0; Prod_FlowEstimatedSlw : Real := 0.0; FillingTime : Real := 3.565371; Head_CIP_Rinse : Bool := TRUE; Head_Drain : Bool := FALSE; EstimatedFlowEnable : Bool := TRUE; gBlendFillStartUp_EnBlen : Bool := FALSE; Prod_HeadPIDMax_Freq : Real := 50.0; mKp_Loss : Real := 0.017; FillerHead : STRUCT ConfigPID : Bool := FALSE; Hold_Int : Bool := TRUE; I_ITL : Bool := FALSE; Alarm : Bool := FALSE; Spare0_4 : Bool := FALSE; Spare0_5 : Bool := FALSE; Spare0_6 : Bool := FALSE; Config : Bool := TRUE; PID_FIX : Bool := TRUE; Spare1_1 : Bool := FALSE; High_Limit : Bool := FALSE; Low_Limit : Bool := FALSE; ManualControl : "Struct"; Bp : Real := 50.0; Ti : Real := 3.0; Td : Real := 5.0; Ff : Real := 0.0; KP : Real := 2.0; Pv : Real := -948.5061; OutMan : Real := 5850.0; Lsp : Real := 700.0; OutMaxHmi : Real := 100.0; OutMin : Real := 6.5; OutMax : Real := 16250.0; Spare52 : Real := 0.0; FfOut : Real := 1219.204; Sp : Real := 700.0; Out : Real := 0.0; Cycle_Time : Real := 0.3; I_ITLVAL : Real := 0.0; Dead_Band : Real := 0.0; END_STRUCT; END_VAR BEGIN // Data Blocks have no executable code END_DATA_BLOCK ```