```pascal // Block Type: OB // Block Number: 1 // Original Network Languages: LAD ORGANIZATION_BLOCK "_CYCL_EXC" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_TEMP OB1_EV_CLASS : Byte; OB1_SCAN_1 : Byte; OB1_PRIORITY : Byte; OB1_OB_NUMBR : Byte; OB1_RESERVED_1 : Byte; OB1_RESERVED_2 : Byte; OB1_PREV_CYCLE : Int; OB1_MIN_CYCLE : Int; OB1_MAX_CYCLE : Int; OB1_DATE_TIME : "Date_And_Time"; Aux_Word : Real; Aux_Word_2 : Real; t : Int; END_VAR BEGIN // Network 1: Always OFF (Original Language: LAD) // AUXILIARY MEMORY - FALSE Memory IF "AUX FALSE" THEN "AUX FALSE" := FALSE; END_IF; // Network 2: Always ON (Original Language: LAD) // AUXILIARY MEMORY - TRUE Memory IF "AUX TRUE" THEN "AUX TRUE" := TRUE; END_IF; // Network 3: Blender CTRL (Original Language: LAD) BlenderCtrl__Main(); // Network 4: Scroll Message for screen (Original Language: LAD) MessageScroll(Code := "HMI_Alarms"."gH_Message_code", Data_B := "HMI_Alarms", First := 20, Last := 30, Time_Vis := "MessageScroll_Time"); // Network 5: Scroll Machine Status for screen (Original Language: LAD) MessageScroll(Code := "HMI_Alarms"."gH_Status_code", Data_B := "HMI_Alarms", First := 34, Last := 43, Time_Vis := "StatusScroll_Time"); // Network 6: ITC Main Routine (Original Language: LAD) ITC_MainRoutine(); // Network 7: CO2 Counters (Original Language: LAD) "Co2_Counters_DB"(); // Network 8: ProdBrix Recovery (Original Language: LAD) "ProdBrixRecovery_DB"(); // Network 9: Hmi Key (Original Language: LAD) IF "Disable_Bit" THEN "Key Read & Write Data"(); END_IF; // Network 10: (Original Language: LAD) // W.O. 08/07/2022 Modifica per ridurre la velocità di produzione legata al rapporto di proporzione IF "AUX TRUE" THEN "Blender_Constants"."gBlenderNominalSpeedAdj" := 1.05; END_IF; // Network 11: (Original Language: LAD) GNS_PLCdia_MainRoutine(); // Network 12: (Original Language: LAD) // Network 12 has no logic elements. END_ORGANIZATION_BLOCK ```