#### Brake without DynaStop option: ![[Pasted image 20241107151714.png]] #### DynaStop enabled motors: *** ![[Imagen de WhatsApp 2024-11-07 a las 14.49.30_547095fc.jpg|625]] # Activating the function https://download.sew-eurodrive.com/download/html/27802922/en-EN/2508655041141416666507.html ##### Danger due to falling loads. ##### Severe or fatal injuries. - Do **not** use the "Release brake/deactivate DynaStop® with FCB01" function in lifting devices or applications with loads that might potentially fall down. - Inhibit the function via the following steps: - Deactivate the function of DIP switch S1/2 using parameter _Deactivation_ = **"1"** (Path: _Functions > Inputs/Outputs > Basic device > DIP switch functions > Release brake/deactivate DynaStop_® _deactivate with FCB01_ – _Enable_) - Inhibit the function using the parameter _Release brake/deactivate DynaStop® with FCB 01 – enable_ = **"0"** (path: _Functions_ > _Drive functions_ > _FCB 01 Output stage inhibit_). In case the output stage is inhibited by a control signal (digital input or process data bit), the DynaStop® function can be deactivated using the function "Release brake/deactivate DynaStop® with FCB01". For example, this allows to move loads freely using a horizontal conveyor. Now make the following settings: 1. **Enabling the function**: - **Via DIP switch S1/2** you switch the DIP switch S1/2 "Release brake/deactivate DynaStop® with FCB01 – enable" = ON. - **Via the parameter setting** you deactivate DIP switch S1/2 by setting the parameter _Deactivation_ = **"1"**. (Path: _Functions_ > _Input/outputs_ > _Basic device_ > _DIP switch functions_ > _Release brake/deactivate DynaStop_® _with FCB01 – release)_ Release the function "Release brake/deactivate DynaStop® for FCB01 – enable" by setting the parameter _Release brake/deactivate DynaStop_® _for FCB01 – release_ = **"1"** [1]. (Path: _Functions_ > _Drive functions_ > _FCB 01 Output stage inhibit_) ![](https://download.sew-eurodrive.com/download/html/27802922/Images/png/18014420484359179__en__Web.png) ![](https://download.sew-eurodrive.com/download/html/27802922/assets/img/icons/x_white.png) 5. **Configuring the control signal**: - **Control via digital input** Assign a digital input with the function "Release brake/deactivate DynaStop® with FCB01" [2]. ![](https://download.sew-eurodrive.com/download/html/27802922/Images/png/18014420484362123__en__Web.png) ![](https://download.sew-eurodrive.com/download/html/27802922/assets/img/icons/x_white.png) - **Control via process data bit** (not available in DBC designs) Assign a process output bit with the function "Release brake/deactivate DynaStop® with FCB01" [3]. ![](https://download.sew-eurodrive.com/download/html/27802922/Images/png/27021619739106059__en__Web.png) ![](https://download.sew-eurodrive.com/download/html/27802922/assets/img/icons/x_white.png) The set control signal can be used to deactivate DynaStop® when the function block FCB01 is active. ### On the manual ![[Pasted image 20240925131406.png]] ### To be tested *** ![[Pasted image 20240925131415.png]]