#### Logic "FC TTOP AUTEFA 2 PH" *** * This logic uses 4 fix speed * 3 Sensors: * NxSA : Next motor SA photocell -> Timer 04 / 05-06 Jam * NxSB: Next motor SB photocell -> Timer 06 Jam * SA : actual motor SA photocell -> Timer 03 / 05 Jam * SA : Timer 01: SA * SB : Timer 02: SB * FIX1: ( empty ) * By default * FIX2: only 1 photocell accumulation * NxSA e non SA e SB * FIX3: 2 photocells accumulation * No SA + SB + NxSA o SA + SB NO NxSA : Two photocells but not 3 * FIX4: 3 photocells ( Full ) * All 3 photocells