{"path":"01-Documentation/Inverters/Siemens/adjuntos/Pasted image 20240703102130.png","text":"B E saveproject @ X H E X D F [& S coonline g cootfine a MM % ) L E PORTAL 93674_TL23 Q4_09 » RT100 [G120CPN] » Parameter -Ex i EE rrr 1) @2 3 & B3 2 @ @ o E HM alarms Number Parameter text Value Uit T & Recipes All parameters MC A ] ae ) A E i o © » Da scripts Commissioning interface piS Macro drive unit A [5] Conveyor technology with fieldbus and Basic 5. E 5] scheduled tasks Backup & restore r47 Motor data identification and speed controller optimization [0] No measurement ¢ ) cycles System information P96 Application class a [0] Expert » @) Reports Basic settings p205 Power unit application A [0] Load duty cycle with high overload for vector . 3 £] Textand graphic lists > Inputsioutputs p230 Drive filter type motor side a 01 No filter £ $9 User administration ) Setpoint channel p304/0] Rated motor voltage a 400 Vrms E » [ VM_TL23_HMI_Q4_PULPITO [TP900 Comfort] ) Operating mode p305[0] Rated motor current a 175 Arms ~ l RT100 [G120C PN] o ) Drive functions p307[0] Rated motor power a 075 kW IY Device configuration SafetyIntegrated p308[0] Rated motor power factor a 0.000 & Online & diagnostics » Application functions p310[0] Rated motor frequency a 5000 Hz ¥ Parameter e » Communication p31110] Rated motor speed a 14500 rpm 1 Commissioning ) Diagnostics p3220] Maximum motor speed a 00 rpm @ Acceptance test p32310] Maximum motor current a 000 Ams ) @ Traces p340[0] Automatic calculation motoricontrol parameters a [0] No calculation ~ l& RTI01 [6120C PN] p500 Technology application a [0] Standard drive H} Device configuration p501 Technological application (Standard Drive Control) a [0] Constant load (linear characteristic) (%] online & diagnostics poz2 PROFIdrive PZD telegram selection @ [999] Free telegram configuration with BICO % Parameter » p100ofo] Speed setpoint selection a [6] No supplementary setpoint + Fieldbus jj commissioning pi470[0] — Speed controller encoderless operation Pgain ST 30 ® Acceptance test p1472[0] Speed controllerencoderless operation integralime [ 1440 » a Teces E R e @) @ “ l& RT102 [G120C PN] Completion of quick commissioning a ° [0] No quick parameterization H Device configuration 2] Online & diagnostics 1% Parameter 1i Commissioning @ Acceptance test o","libVersion":"0.3.2","langs":"eng+ita"}