Obsidean_VM/.obsidian/plugins/text-extractor/cache/f5cb41c7f9847825f5e130e2741...

1 line
173 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters

This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.

{"path":"03-VM/9.... Nuovo Ordine - Logoplast - NFC Batch/adjuntos/Ident_Configuration_Guide_2022-07.pdf","text":"SIMATIC Ident Configuration Guide Unrestricted © Siemens 2022. All rights reserved. siemens.com/ident July 2022 Edition: July 2022 Corrections mailto: markus.haeuser@siemens.com SIMATIC Ident Configuration Guide Content Select and configure a SIMATIC RF Family ................................ 3 RF200 Family Matrix ................................................................................. 4 System Interfaces ......................................................................... 16 RF300 Family Matrix ................................................................................ 21 System Interfaces .......................................................................... 33 RF600 Family Matrix ............................................................................... 37 System Interfaces ......................................................................... 43 RF1000 Family Matrix ............................................................................... 46 System Interfaces ......................................................................... 48 RF Handheld Reader ........................................................................ 51 Configure an Optical Identification System MV500 System Interfaces ................................................................ 53 MV300 System Interfaces ................................................................ 67 System interfaces for general purpose serial devices Bill of Materials Guide RF18xC / CI .................................................................................. 70 RF166C ........................................................................................ 72 RF360R ........................................................................................ 73 Bulk Cable and Connectors ............................................................... 74 All selection possibilities of this SIMATIC Ident Configuration Guide can also be found in the TIA Selection Tool. This tool is available at: http://www.siemens.com/tst Other functional highlights of the selection tool: Create order lists Get price information by application to the mall Select other automation components (control devices, IO-Systems, industrial communication) Network view of all components Retrieve and compare technical data and much more All current wireless approvals can be found on the Internet at: http://www.siemens.com/rfid-approvals Important notes: The newest version of this configuration guide is published at: https://support.industry.siemens.com/cs/ww/en/view/67384964 Edition: July 2022 3 Each SIMATIC RF Family has characteristics that orients it to a particular range of applications: The first step is to understand the application by asking the right questions. Out of this process, the best-suited SIMATIC RF family can be determined A reader and tag combination within the specific family can be selected using the SIMATIC RF family matrix pages Within the chosen family, a network interface to the control system can be selected using the system interfaces pages SIMATIC Ident Configuration Guide Technology HF UHF What is the basic RF technology? RF200 13.56 MHz 868/915 MHz RF600 Read Distance Shorter Longer How far away can the tag be from the reader antenna system and still be seen? Tag Memory Less More How many bytes are required to be stored on the tag? Metal Effects Direct Mount Spacer Mount Do tags and reader need to be mounted on or around metal? Tag Dimensions Smallest Largest What is the smallest tag size available? Environment Heavy Heavy What kind of environmental extremes will the tags be subjected to? RF300 220°C IP68 RF200 220°C IP68 230°C IP68 RF600 Reader Dimensions Smallest Largest How much space will there be for mounting the reader/ antenna? Multitag Mode Less More Will there be more than one tag in the RF field at a time? Tag Speed Slower Faster How fast will the tag be traveling through the RF field? Air Interface Protocol Siemens Standard Are there any requirements regarding the air interface protocol? RF1000 30 mm RF200 650 mm 8 meters RF600 384 bytes RF600 RF200 8 kbytes RF300 64 kbytes RF300 Direct with reduction Direct with reduction RF600 RF200 Spacer Mount RF300 Ø 4 x 5 mm RF200 Ø 4 x 5 mm Ø 21 x 20 mm RF600 RF300 M12 x 40 RF200 M8 x 38 75 x 75 x 20 RF600 RF300 1 RF200 1 100+ RF600 RF300 100 kbits/sec RF200 26 kbits/sec 300 kbits/sec RF600 RF300 Siemens/ ISO15693/14443 RF200 ISO 15693 ISO 18000 -62/ -63 RF600 RF300 13.56 MHz RF1000 125 kHz + 13.56 MHz RF300 210 mm RF1000 ISO15693/14443 Legic, Emxx/Hitag Edition: July 2022 RF210R/ RF210M 6GT2 821-1AC10, RS422 6GT2 821-1AC32 / -1BC32, IO-Link* 6GT2 823-0AA00, Handheld (RS422) Integrated 1-10/ 12 (0.04-0.39/ 0.47) 1-8/ 9 (0.04-0.31/ 0.35) 1-8/ 9 (0.04-0.31/ 0.35 RF220R 6GT2 821-2AC10, RS422 6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 1-20/ 22 (0.04-0.79/ 0.87) 1-18/ 20 (0.04-0.71/ 0.79) 1-18/ 20 (0.04-0.71/ 0.79 RF240R 6GT2 821-4AC10, RS422 6GT2 821-4AC40, RS232 (ASCII) 6GT2821-4AC32 / -4BC32, IO-Link* Integrated 2-80/ 94 (0.08-3.15/ 3.70) 2-60/ 70 (0.08-2.36/ 2.76) 2-84/ 95 (0.08-3.31/ 3.74) 2-69/ 78 (0.08-2.72/ 3.07) 2-80/ 90 (0.08-3.15/ 3.54) 1-33/ 37 (0.04-1.30/ 1.46) 1-30/ 34 (0.04-1.18/ 1.34) 1-30/ 34 (0.04-1.18/ 1.34) RF250R ANT 1 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CB00, ANT 1 5-95/ 110 (0.20-3.74/ 4.33) 2-90/ 110 (0.08-3.54/ 4.33) 5-95/ 115 (0.20-3.74/ 4.53) 5-90/ 100 (0.20-3.54/ 3.94) 10-95/ 110 (0.39-3.74/ 4.33) 2-35/ 45 (0.08-1,38/ 1.77) 2-30/ 40 (0.08-1.18/ 1.57) 2-30/ 40 (0.08-1.18/ 1.57) RF250R ANT 3 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD40-0AX0, ANT 3 1-23/ 30 (0.04-0.91/1.18) 1-21/ 27 (0-0.83/ 1.06) 1-21/ 27 (0.04-0.83/ 1.06) RF250R ANT 3S 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD60-0AX0, ANT 3S RF250R ANT 8 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CF10, ANT 8 RF250R ANT 12 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DC10, ANT 12** 1-12/ 17 (0.04-0.47/ 0.67) 1-10/ 14 (0.04-0.39/ 0.55) 1-10/ 14 (0.04-0.39/ 0.55 Accessories Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) M18 x 71 M30 x 71 50 x 50 x 30 Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags 4 Ø8 x 38 Ø12 x 40 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 -40°C to 175°C Ø 16 x 3 IP68/IPx9K D160 6GT2 600-0AB10 112 byte EEPROM AntennasRF200 Family Matrix 75 x 75 x 20 D560 6GT2 600-5AB00 8 kbyte FRAM -40°C to 90°C Ø 16 x 3 IP68/IPx9K D200 6GT2 600-1AD00 -0AX0 256 byte EEPROM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D400 6GT2 600-4AD00 2 kbyte FRAM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D165 6GT2 600-1AB00-0AX0 112 byte EEPROM -25°C to 85°C 86 x 54 x 0.3 IP65 D261 6GT2 600-1AA01-0AX0 256 byte EEPROM -25°C to 85°C 55 x 55 x 0.3 IP65 -40°C to 100°C Ø 16 x 3 IP67/IPx9K D460 6GT2 600-4AB00 2 kbyte FRAM Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) D100 6GT2 600-0AD10 112 byte EEPROM -25°C to 80°C 85,6 x 54 x 0.9 IP68 Edition: July 2022 RF250R ANT 18 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DA10, ANT 18** 1-18/ 26 (0.04-0.71/ 1.02) 1-17/ 21 (0.04-0.67/ 0.83) 1-17/ 21 (0.04-0.67/ 0.83) RF250R ANT 30 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DD10, ANT 30 1-23/ 30 (0.04-0.91/ 1.18) 1-21/ 27 (0.04-0.83/ 1.06) 1-21/ 27 (0.04-0.83/ 1.06) RF260R 6GT2 821-6AC10, RS422 6GT2 821-6AC40, RS232 (ASCII) 6GT2 821-6AC32 / -6BC32, IO-Link* Integrated 2-120/ 135 (0.08-4.72/ 5.31) 2-75/ 90 (0.08-2.95/ 3.54) 2-110/ 130 (0.08-4.33/ 5.12) 2-100/ 120 (1.18-3.94/ 4.72) 2-90/ 120 (0.08-3.54/ 4.72) 2-40/ 45 (0.08-1.57/ 1.77) 2-40/45 (0.08-1.57/ 1.77) 2-40/45 (0.08-1.57/ 1.77) RF280R 6GT2 821-8AC10, RS422 6GT2 821-8AC40, RS232 (ASCII) Integrated 10 -160/ 190 (0.39-6.3/ 7.48) 20-110/ 150 (0.79-4.33/ 5.91) 10-160/ 200 (0.39-6.3/ 7.87) 20-140/ 185 (0.79-5.51/ 7.28) 5-150/ 180 (0.20-5.91/ 7.09) 2-55/ 70 (0.08-2.17/ 2.76) 2-55/ 70 (0.08-2.17/ 2.76) 2-55/ 70 (0.08-2.17/ 2.76) Accessories Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) 13.56 MHz Passive Tags 5 AntennasRF200 Family Matrix D560 6GT2 600-5AB00 8 kbyte FRAM -40°C to 90°C Ø 16 x 3 IP68/IPx9K D200 6GT2 600-1AD00 -0AX0 256 byte EEPROM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D400 6GT2 600-4AD00 2 kbyte FRAM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D165 6GT2 600-1AB00-0AX0 112 byte EEPROM -25°C to 85°C 86 x 54 x 0.3 IP65 D261 6GT2 600-1AA01-0AX0 256 byte EEPROM -25°C to 85°C 55 x 55 x 0.3 IP65 -40°C to 100°C Ø 16 x 3 IP67/IPx9K D460 6GT2 600-4AB00 2 kbyte FRAM Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) SIMATIC Ident Configuration Guide Ø30 x 40 Ø18 x 40 -40°C to 175°C Ø 16 x 3 IP68/IPx9K D160 6GT2 600-0AB10 112 byte EEPROM Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating * not with Tags D5xx ** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) D100 6GT2 600-0AD10 112 byte EEPROM -25°C to 80°C 85,6 x 54 x 0.9 IP68 Edition: July 2022 RF290R 6GT2 821-0AC12, RS232, RS422 10-180/ 250 (0.39-7.09/ 9.84) 5-130/ 180 (0.39-5.12/ 7.09) 10-180/ 250 (0.39-7.09/ 9.84) 10-170/240 (0.39-6.69/ 9.45) 10-170/240 (0.39-6.69/ 9.45) 1-65/90 (0.04-2.56/ 3.54) 1-60/85 (0.04-2.36/ 3.35) 1-60/85 (0.04-2.36/ 3.35) 1-350/ 450 (0.04-13.78/ 17.72) 1-300/ 400 (0.04-11.81 / 15.75) 1-400/ 500 (0.04-15.75/ 19.69) 1-400/ 500 (0.04-15.75/ 19.69) 1-300/ 375 (0.04-11.81/ 14.76) 1-130/ 180 (0.04-5.12/ 7.09) 1-120/ 160 (0.04-4.72/ 6.30) 1-120/ 160 (0.04-4.72/ 6.30) 1-400/ 500 (0.04-15.75/ 19.69) 1-350/ 450 (0.04-13.78 / 17.72) 1-550/ 650 (0.04-21.65/ 25.59) 1-500/ 600 (0.04-19.69/ 23.62) 1-500/ 650 (0.04-19.69/ 25.59) 1-350/ 450 (0.04-13.78/ 17.72) 1-350/ 450 (0.04-13.78 / 17.72) 1-500/ 600 (0.04-19.69/ 23.62) 1-450/ 550 (0.04-17.72/ 21.65) 1-400/ 500 (0.04-15.75/ 19.69) Accessories Covering hood for ANT D6 (6GT2 690-0AD00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) 13.56 MHz Passive Tags 6 AntennasRF200 Family Matrix D560 6GT2 600-5AB00 8 kbyte FRAM -40°C to 90°C Ø 16 x 3 IP68/IPx9K D200 6GT2 600-1AD00 -0AX0 256 byte EEPROM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D400 6GT2 600-4AD00 2 kbyte FRAM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D165 6GT2 600-1AB00-0AX0 112 byte EEPROM -25°C to 85°C 86 x 54 x 0.3 IP65 D261 6GT2 600-1AA01-0AX0 256 byte EEPROM -25°C to 85°C 55 x 55 x 0.3 IP65 -40°C to 100°C Ø 16 x 3 IP67/IPx9K D460 6GT2 600-4AB00 2 kbyte FRAM Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) SIMATIC Ident Configuration Guide -40°C to 175°C Ø 16 x 3 IP68/IPx9K D160 6GT2 600-0AB10 112 byte EEPROM 6GT2 698-5AB00 580 x 480 x 110 ANT D6 6GT2 698-5AF00 1150 x 365 x 115 ANT D10 6GT2 698-5AA10 380 x 380 x 110 ANT D5 Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 6GT2 698-5AC00 75 x 75 x 20 ANT D1 Accessory: Set for top rail mounting 6GK5798-8ML00-0AB3 D100 6GT2 600-0AD10 112 byte EEPROM -25°C to 80°C 85,6 x 54 x 0.9 IP68 Edition: July 2022 Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF210R/ RF210M 6GT2 821-1AC10, RS422 6GT2 821-1AC32 / -1BC32, IO-Link* 6GT2 823-0AA00, Handheld (RS422) Integrated 0-2/ 2 (0-0.08/ 0.08) 0-3/ 4 (0.0-0.12/ 0.16) 0-3/ 4 (0-0.12/ 0.16) 1-9/ 10 (0.04-0.35/ 0.39) 1-8/ 9 (0.04-0.31/ 0.35) RF220R 6GT2 821-2AC10, RS422 6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 1-12/ 14 (0.04-0.47/ 0.55) 1-10/ 12 (0.04-0.39/ 0.47) RF240R 6GT2 821-4AC10, RS422 6GT2 821-4AC40, RS232 (ASCII) 6GT2821-4AC32 / -4BC32, IO-Link* Integrated 1-12/ 15 (0.04-0.47/ 0.59) 1-10/ 12 (0.04-0.39/ 0.47) RF250R ANT 1 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CB00, ANT 1 RF250R ANT 3 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD40-0AX0, ANT 3 1-12/ 15 (0.04-0.47/ 0.59) 1-12/ 15 (0.04-0.47/ 0.59) RF250R ANT 3S 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD60-0AX0, ANT 3S 0-2/ 3 (0-0.08/ 0.12) 0-2/ 3 (0-0.08/ 0.12) 0-3/ 4 (0-0.12/ 0.16) 0-3/ 4 (0-0.12/ 0.16) RF250R ANT 8 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CF10, ANT 8 0-2/ 3 (0-0.08/ 0.12) 0-3/ 4 (0-0.12/ 0.16) 0-3/ 4 (0-0.12/ 0.16) 0-3/ 4 (0-0.12/ 0.16) RF250R ANT 12 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DC10, ANT 12** 0-3/ 4 (0-0.12/ 0.16) 0-4/ 5 (0-0.16/ 0.2) 0-2/ 4 (0-0.12/ 0.16) 0-3/ 4 (0-0.12/ 0.16) 0-7/ 10 (0-0.28/ 0.39) 1-7/ 9 (0.04-0.28/ 0.35) Accessories Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags 7 RF200 Family Matrix Antennas SIMATIC Ident Configuration Guide D422 6GT2 600-4AF00 2 kbyte FRAM -40°C to 100°C Ø20 x 6 IP68 D127 6GT2 600-0AF00 112 byte EEPROM -40°C to 125°C Ø 6 x 5.8 IP68/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D421 6GT2 600-4AE00 2 kbyte FRAM -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D521 6GT2 600-5AE00 8 kbyte FRAM D522 6GT2600-5AF00 6GT2600-5AF00-0AX0 8 kbyte FRAM -40°C to 100°C Ø20 x 6 ; Ø18 x 5.2 IP68 Ø8 x 38 Ø12 x 40 28 x 50 x 10 28 x 50 x 10 M18 x 71 50 x 50 x 30 M30 x 71 75 x 75 x 20 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) -40°C to 125°C Ø4 x 5.2 IP68 IPx9K D117 6GT2 600-0AG00 112 byte EEPROM Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF250R ANT 18 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DA10, ANT 18** 0-3/ 5 (0-0.12/ 0.20) 0-4/ 5 (0-0.16/ 0.20) 1-8/ 14 (0.04-0.31/ 0.55) 1-10/ 12 (0.04-0.39/ 0.47) RF250R ANT 30 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DD10, ANT 30 1-12/ 15 (0.04-0.47/ 0.59) 1-12/ 15 (0.04-0.47/ 0.59) RF260R 6GT2 821-6AC10, RS422 6GT2 821-6AC40, RS232 (ASCII) 6GT2 821-6AC32 / -6BC32, IO-Link* Integrated RF280R 6GT2 821-8AC10, RS422 6GT2 821-8AC40, RS232 (ASCII) Integrated Accessories 8 75 x 75 x 41 SIMATIC Ident Configuration Guide Ø18 x 40 160 x 96 x 41 Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags RF200 Family Matrix Antennas D422 6GT2 600-4AF00 2 kbyte FRAM -40°C to 100°C Ø20 x 6 IP68 D127 6GT2 600-0AF00 112 byte EEPROM -40°C to 125°C Ø 6 x 5.8 IP68/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D421 6GT2 600-4AE00 2 kbyte FRAM -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D521 6GT2 600-5AE00 8 kbyte FRAM D522 6GT2600-5AF00 6GT2600-5AF00-0AX0 8 kbyte FRAM -40°C to 100°C Ø20 x 6 ; Ø18 x 5.2 IP68 -40°C to 125°C Ø4 x 5.2 IP68 IPx9K D117 6GT2 600-0AG00 112 byte EEPROM Ø30 x 40 * not with Tags D5xx ** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF290R 6GT2 821-0AC12, RS232, RS422 Accessories Covering hood for ANT D6 (6GT2 690-0AD00) 6GT2 698-5AB00 580 x 480 x 110 ANT D6 6GT2 698-5AF00 1150 x 365 x 115 ANT D10 6GT2 698-5AA10 380 x 380 x 110 ANT D5 9 Accessory: Set for top rail mounting 6GK5798-8ML00-0AB3 SIMATIC Ident Configuration Guide 6GT2 698-5AC00 75 x 75 x 20 ANT D1 Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags RF200 Family Matrix Antennas D422 6GT2 600-4AF00 2 kbyte FRAM -40°C to 100°C Ø20 x 6 IP68 D127 6GT2 600-0AF00 112 byte EEPROM -40°C to 125°C Ø 6 x 5.8 IP68/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D421 6GT2 600-4AE00 2 kbyte FRAM -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D521 6GT2 600-5AE00 8 kbyte FRAM D522 6GT2600-5AF00 6GT2600-5AF00-0AX0 8 kbyte FRAM -40°C to 100°C Ø20 x 6 ; Ø18 x 5.2 IP68 -40°C to 125°C Ø4 x 5.2 IP68 IPx9K D117 6GT2 600-0AG00 112 byte EEPROM Edition: July 2022 Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF210R/ RF210M 6GT2 821-1AC10, RS422 6GT2 821-1AC32 / -1BC32, IO-Link* 6GT2 823-0AA00, Handheld (RS422) Integrated 1-18/ 20 (0.04-0.71/ 0.79) 1-8/ 9 (0.04-0.31/ 0.35) 1-16/ 18 (0.04-0.63/ 0.71) 1-15/ 17 (0.04-0.59/ 0.67) RF220R 6GT2 821-2AC10, RS422 6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 1-28/ 31 (0.04-1.10/ 1.22) 2-21/ 25 (0.08-0.83/ 0.98) 2-25/ 29 (0.08-0.98/ 1.14) 2-22/ 25 (0.08-0.87/ 0.98) 2-30/ 35 (0.08-1.18/ 1.38) 2-25/ 30 (0.08-0.98/ 1.18) 2-25/ 30 (0.08-0.98/ 1.18) RF240R 6GT2 821-4AC10, RS422 6GT2 821-4AC40, RS232 (ASCII) 6GT2821-4AC32 / -4BC32, IO-Link* Integrated 2-53/ 60 (0.08-2.09/ 2.36) 1-36/ 40 (0.04-1.42/ 1.57) 1-47/ 53 (0.04-1.85/ 2.09) 1-45/ 55 (0.04-1.77/ 2.17) 2-57/ 65 (0.08-2.24/ 2.56) 2-45/ 55 (0.08-1.77/ 2.17) 2-45/ 55 (0.08-1.77/ 2.17) RF250R ANT 1 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CB00, ANT 1 2-60/ 75 (0.08-2.36/ 2.95) 5-60/ 70 (0.20-2.36/ 2.76) 2-70/ 80 (0.08-2.76/ 3.15) 1-65/ 80 (0.04-2.56/ 3.15) 2-80/ 95 (0.08-3.15/ 3.74) 2-80/ 95 (0.08-3.15/ 3.74) 2-80/ 95 (0.08/3.15/ 3.74) RF250R ANT 3 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD40-0AX0, ANT 3 2-32/ 40 (0.08-1.26/ 1.57) 2-22/ 35 (0.08-0.87/ 1.38) 1-34/ 48 (0.04-1.34/ 1.89) 1-35/ 40 (0.04-1.38/ 1.57) 1-47/ 60 (0.04-1.85/ 2.36) 1-44/ 58 (0.04-1.73/ 2.28) 2-35/ 45 (0.08-1.38/ 1.77) RF250R ANT 3S 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD60-0AX0, ANT 3S RF250R ANT 8 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CF10, ANT 8 RF250R ANT 12 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DC10, ANT 12** Accessories Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) M18 x 71 M30 x 71 50 x 50 x 30 10 Antennas Ø8 x 38 Ø12 x 40 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 D124 6GT2 600-0AC10 112 byte EEPROM -40°C to 180°C Ø 27 x 4 IP68/ IPx9K D324 6GT2 600-3AC00 992 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67 D424 6GT2 600-4AC00 2 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K D524 6GT2 600-5AC00 8 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K 75 x 75 x 20 Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags RF200 Family Matrix Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) D426 6GT2 600-4AH00 2 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D526 6GT2 600-5AH00 8 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D126 6GT2 600-0AE00 112 byte EEPROM -40°C to 100°C Ø 50 x 3.6 IP68 Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF250R ANT 18 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DA10, ANT 18** 1-24/ 37 (0.04-0.94/ 1.46) 1-18/ 27 (0.04-0.71/ 1.06) 1-27/ 36 (0.04-1.06/ 1.42) 1-25/ 30 (0.04-0.98/ 1.18) RF250R ANT 30 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DD10, ANT 30 1-35/ 48 (0.08-1.38/ 1.89) 1-22/ 35 (0.04-0.87/ 1.38) 1-34/ 48 (0.04-1.34/ 1.89) 1-35/ 40 (0.04-1.38/ 1.57) 1-47/ 60 (0.04-1.85/ 2.36) 1-44/ 58 (0.04-1.73/ 2.28) 2-44/ 50 (0.08-1.73/ 1.97) RF260R 6GT2 821-6AC10, RS422 6GT2 821-6AC40, RS232 (ASCII) 6GT2 821-6AC32 / -6BC32, IO-Link* Integrated 2-80/ 85 (0.08-3.15/ 3.35) 2-60/ 70 (0.08-2.36/ 2.76) 2-60/ 70 (0.08-2.36/ 2.76) 2-60/ 70 (0.08-2.36/ 2.76) 2-75/ 100 (0.08-2.95/ 3.94) 2-70/ 85 (0.08-2.76/ 3.35) 2-70/ 85 (0.08-2.76/ 3.35) RF280R 6GT2 821-8AC10, RS422 6GT2 821-8AC40, RS232 (ASCII) Integrated 2-110/ 130 (0.08-4.33/ 5.12) 2-85/ 110 (0.08-3.35/ 4.33) 2-100/ 140 (0.08-3.94/ 5.51) 2-110/ 130 (0.08-4.33/ 5.12) 2-135/ 160 (0.08-5.31/ 6.3) 2-145/ 175 (0.08-5.71/ 6.89) 2-135/ 165 (0.08-5.31/ 6.5) Accessories Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) 1111SIMATIC Ident Configuration Guide Ø30 x 40 Ø18 x 40 75 x 75 x 41 160 x 96 x 41 Antennas D124 6GT2 600-0AC10 112 byte EEPROM -40°C to 180°C Ø 27 x 4 IP68/ IPx9K D324 6GT2 600-3AC00 992 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67 D424 6GT2 600-4AC00 2 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K D524 6GT2 600-5AC00 8 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags RF200 Family Matrix D426 6GT2 600-4AH00 2 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D526 6GT2 600-5AH00 8 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D126 6GT2 600-0AE00 112 byte EEPROM -40°C to 100°C Ø 50 x 3.6 IP68 * not with Tags D5xx ** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF290R 6GT2 821-0AC12, RS232, RS422 1-100/ 140 (0.04-3.94/ 5.51) 1-90/ 130 (0.04-3.54/ 5.12) 1-90/ 130 (0.04-3.54/ 5.12) 1-90/ 130 (0.04-3.54/ 5.12) 5-110/150 (0.20-4.34/ 5.91) 5-100/ 140 (0.20-3.94/ 5.51) 5-100/ 140 (0.20-3.94/ 5.51) 1-200/ 280 (0.04-7.87/ 11) 1-200/ 280 (0.04-7.87/ 11) 1-200/ 280 (0.04-7.87/ 11) 1-200/ 280 (0.04-7.87/ 11) 1-350/ 400 (0.04-13.78/ 15.75) 1-300/ 350 (0.04-11.81/ 13.78) 1-300/ 350 (0.04-11.81/ 13.78) 1-220/ 300 (0.04-8.66/ 11.81) 1-200/ 280 (0.04-7.87/ 11) 1-220/ 300 (0.04-8.66/ 11.81) 1-220/ 300 (0.04-8.66/ 11.81) 1-400/ 500 (0.04-15.75/ 19.69) 1-350/ 400 (0.04-13.78/ 15.75) 1-350/ 400 (0.04-13.78/ 15.75) 1-200/ 280 (0.04-7.87/ 11) 1-200/ 280 (0.04-7.87/ 11) 1-200/ 280 (0.04-7.87/ 11) 1-220/ 300 (0.04-8.66/ 11.81) 1-400/ 500 (0.04-15.75/ 19.69) 1-350/ 400 (0.04-13.78/ 15.75) 1-350/ 400 (0.04-13.78/ 15.75) Accessories Covering hood for ANT D6 (6GT2 690-0AD00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) 1212 Accessory: Set for top rail mounting 6GK5798-8ML00-0AB3 SIMATIC Ident Configuration Guide 6GT2 698-5AB00 580 x 480 x 110 ANT D6 6GT2 698-5AF00 1150 x 365 x 115 ANT D10 6GT2 698-5AA10 380 x 380 x 110 ANT D5 6GT2 698-5AC00 75 x 75 x 20 ANT D1 Antennas D124 6GT2 600-0AC10 112 byte EEPROM -40°C to 180°C Ø 27 x 4 IP68/ IPx9K D324 6GT2 600-3AC00 992 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67 D424 6GT2 600-4AC00 2 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K D524 6GT2 600-5AC00 8 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags RF200 Family Matrix D426 6GT2 600-4AH00 2 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D526 6GT2 600-5AH00 8 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D126 6GT2 600-0AE00 112 byte EEPROM -40°C to 100°C Ø 50 x 3.6 IP68 Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF210R/ RF210M 6GT2 821-1AC10, RS422 6GT2 821-1AC32 / -1BC32, IO-Link* 6GT2 823-0AA00, Handheld (RS422) Integrated 2-6/ 9 (0,08-0.24/ 0.35) 1-6/ 7 (0.04-0.24/ 0.28) 1-6/ 7 (0.04-0.24/ 0.28) 1-10/ 11 (0.04-0.39/ 0.43) 1-10/ 11 (0.04-0.39/ 0.43) RF220R 6GT2 821-2AC10, RS422 6GT2 821-2AC32 / -2BC32, IO-Link* Integrated 2-16/ 20 (0,08-0.63/0.79) 1-11/ 13 (0.04-0.43/ 0.51) 1-11/ 13 (0.04-0.43/ 0.51) 1-18/ 21 (0.04-0.71/ 0.83) 1-15/ 20 (0.04-0.59/ 0.79) RF240R 6GT2 821-4AC10, RS422 6GT2 821-4AC40, RS232 (ASCII) 6GT2821-4AC32 / -4BC32, IO-Link* Integrated 2-30/ 36 (0.08-1.18/ 1.42) 1-15/17 (0.04-0.59/ 0.67) 1-15/ 17 (0.04-0.59/ 0.67) 1-30/ 34 (0.04-1.18/ 1.34) 1-30/ 35 (0.04-1.18/ 1.38 ) RF250R ANT 1 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CB00, ANT 1 2-42/ 52 (0.08-1.65/ 2.05) 2-25/ 30 (0.08-0.98/ 1.18) 2-25/ 30 (0.08-0.98/ 1.18) 2-40/ 50 (0.08-1.57/ 1.97) 2-40/ 45 (0.08-1.57/ 1.77) 5-90/ 105 (0.2-3.54/ 4.13) 2-85/ 100 (0.08-3.35/ 3.94) RF250R ANT 3 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD40-0AX0, ANT 3 1-24/ 30 (0.04-0.95/ 1.18) 1-12/ 20 (0.04-0.47/ 0.79) 1-12/ 20 (0.04-0.47/ 0.79) 1-20/ 32 (0.04-0.79/ 1.26) 1-20/ 25 (0.04-0.79/ 0.98) RF250R ANT 3S 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CD60-0AX0, ANT 3S RF250R ANT 8 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1CF10, ANT 8 RF250R ANT 12 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DC10, ANT 12** 0-8/ 10 (0.0-0.31/ 0.39) 1-8/ 10 (0.04-0.31/ 0.39) 1-8/ 12 (0.04-0.31/ 0.47) 1-8/ 12 (0.04-0.31/ 0.47) Accessories Mounting cover (6GT2 690-0AE00) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) AntennasRF200 Family Matrix M18 x 71 M30 x 71 50 x 50 x 30 Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags SIMATIC Ident Configuration Guide 1313 D423 6GT2 600-4AA00 2 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/ IPx9K D425 6GT2 600-4AG00 2 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K D525 6GT2 600-5AG00 8 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K D528 6GT2600-5AK00 8 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K Ø8 x 38 Ø12 x 40 28 x 50 x 10 28 x 50 x 10 75 x 75 x 20 D428 6GT2 600-4AK00-0AX0 2 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D139 6GT2 600-0AA10 112 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K D339 6GT2600-3AA10 992 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF250R ANT 18 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DA10, ANT 18** 1-16/ 20 (0.04-0.63/ 0.79) 1-11/ 16 (0.04-0.43/ 0.63) 1-11/ 16 (0.04-0.43/ 0.63) 1-18/ 25 (0.04-0.71/ 0.98) 1-15/ 20 (0.04-0.59/ 0.79) RF250R ANT 30 6GT2 821-5AC10, RS422 6GT2 821-5AC40, RS232 (ASCII) 6GT2821-5AC32 / -5BC32, IO-Link* 6GT2 398-1DD10, ANT 30 1-25 30 (0.04-0.98/ 1.18) 1-12/ 20 (0.04-0.47/ 0.79) 1-20/ 32 (0.04-0.79/ 1.26) 1-20/ 25 (0.04-0.79/ 0.98) RF260R 6GT2 821-6AC10, RS422 6GT2 821-6AC40, RS232 (ASCII) 6GT2 821-6AC32 / -6BC32, IO-Link* Integrated 2-40/ 48 (0.08-1.57/ 1.89) 2-40/ 45 (0.08-1.57/ 1.77) 2-35/ 40 (0.08-1.38/ 1.57) 2-80/ 110 (0.08-3.15/ 4.33) 5-65/ 80 (0.20-2.56/ 3.15) RF280R 6GT2 821-8AC10, RS422 6GT2 821-8AC40, RS232 (ASCII) Integrated 5-65/ 80 (0.20-2.36/ 2.76) 2-30/ 40 (0.08-1.18/ 1.57) 2-30/ 40 (0.08-1.18/ 1.57) 2-60/ 88 (0.08-2.36/ 3.46) 2-60/ 85 (0.08-2.36/ 3.35) 5-150/ 190 (0.20-5.91/ 7.48) 5-150/ 170 (0.20-5.91/ 6.69) Accessories Mounting cover (6GT2 690-0AE00) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) 1414SIMATIC Ident Configuration Guide Ø30 x 40 75 x 75 x 41 Ø18 x 40 160 x 96 x 41 AntennasRF200 Family Matrix Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags D423 6GT2 600-4AA00 2 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/ IPx9K D425 6GT2 600-4AG00 2 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K D525 6GT2 600-5AG00 8 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K D528 6GT2600-5AK00 8 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D428 6GT2 600-4AK00-0AX0 2 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D139 6GT2 600-0AA10 112 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K D339 6GT2600-3AA10 992 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K * not with Tags D5xx ** antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) RF290R 6GT2 821-0AC12, RS232, RS422 10-60/85 (0.39-2.36/ 3.35) 1-55/ 80 (0.04-2.17/ 3.15) 1-55/ 80 (0.04-2.17/ 3.15) 5-160/ 220 (0.20-6.30/ 8.66) 5-130/170 (0.20-5.12/ 6.69) 1-400/ 500 (0.04-15.75/ 19.69) 1-300/ 380 (0.04-11.81/ 15.00) 1-500/ 600 (0.04-19.69/ 23.62) 1-400/ 480 (0.04-15.75/ 18.9) 1-450/ 550 (0.04-17.72/ 21.65) 1-300/ 380 (0.04-11.81/ 15.00) Accessories Covering hood for ANT D6 (6GT2 690-0AD00) Mounting cover (6GT2 690-0AE00) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) 1515 Accessory: Set for top rail mounting 6GK5798-8ML00-0AB3 SIMATIC Ident Configuration Guide 6GT2 698-5AB00 580 x 480 x 110 ANT D6 6GT2 698-5AF00 1150 x 365 x 115 ANT D10 6GT2 698-5AA10 380 x 380 x 110 ANT D5 6GT2 698-5AC00 75 x 75 x 20 ANT D1 AntennasRF200 Family Matrix Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating 13.56 MHz Passive Tags D423 6GT2 600-4AA00 2 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/ IPx9K D425 6GT2 600-4AG00 2 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K D525 6GT2 600-5AG00 8 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K D528 6GT2600-5AK00 8 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D428 6GT2 600-4AK00-0AX0 2 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D139 6GT2 600-0AA10 112 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K D339 6GT2600-3AA10 992 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K Edition: July 2022 RF200 System Interfaces 16 Reader powered through connection cable SIMATIC Ident Configuration Guide RF210M (6GT2 823-0AA00) Opt. Splitter w/ D5, D6 only (6GT2 690-0AC00) ANT D5 (6GT2 698-5AA10) ANT D6 (6GT2 698-5AB00) ANT D10 (6GT2 698-5AF00) ANT D1 (6GT2 698-5AC00) RF210R (6GT2 821-1AC10) RF220R (6GT2 821-2AC10) RF260R (6GT2 821-6AC10) RF240R (6GT2 821-4AC10) RF250R (6GT2 821-5AC10) RF280R (6GT2 821-8AC10) + +2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled: 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 + PROFINET & OPC UA & Ethernet/IP & TCP/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) + Or one Standard sensor Or one Actor A maximum of 1 reader at RF185C, 2 readers at RF186C/CI, 4 readers at RF188C/CI of RF2x0R may be connected * Cable improper for RF290R usage due to length limitation of 20 m ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 8 (6GT2 398-1CF10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) RF290R (6GT2 821-0AC12) Types of IO-Link IO module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information D428 (6GT2 600-4AK00-0AX0) D528 (6GT2600-5AK00) D425 (6GT2 600-4AG00) D525 (6GT2 600-4AB00) D422 (6GT2 600-4AF00) D522 (6GT2 600-5AF00) D522 (6GT2 600-5AF00-0AX0) D421 (6GT2 600-4AE00) D521 (6GT2 600-5AE00) Tags D423 (6GT2 600-4AA00) D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00) D127 (6GT2 600-4AF00) D117 (6GT2 398-1CF00) D165 (6GT2 600-1AB00-0AX0) D261 (6GT2 600-1AA01-0AX0) D139 (6GT2 600-0AA10) D339 (6GT2 600-3AA10) D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00) D526 (6GT2 600-5AH00) D160 (6GT2 600-0AB10) D460 (6GT2 600-4AB00) D560 (6GT2600-5AB00) D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00) D524 (6GT2 600-5AC00) Edition: July 2022 17 A maximum of 2 readers may be connected +RF170C to RF2x0R 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 ET 200pro via PROFIBUS or PROFINET or S7 PLC ++ RF170C Communication module (6GT2002-0HD01) Connection block (6GT2002-1HD01) ET 200pro PROFIBUS DP-V1 Interface module ET 200pro PROFINET Interface module Up to 9 x 170C modules per ET 200pro rack ET 200pro PROFINET CPU module SIMATIC PLC S7-1200 SIMATIC PLC S7-300 Rack or S7-400 via ET 200M (DP-V1/PN-IO) A maximum of 2 readers may be connected +ASM 475 to RF2x0R 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* 2 m = 6GT2 891-4JH20 Reader connector 90° angled 5 m = 6GT2 891-4JH50 Reader connector 90° angled 10 m = 6GT2 891-4JN10 Reader connector 90° angled ASM 475 + Front connector (6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) + + Accessories: Connecting element (6ES7 390-5AA00-0AA0) Terminal element (6ES7 390-5BA00-0AA0) RF200 System Interfaces A maximum of 1 readers may be connected +RF120C to RF2x0R 2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50 10m = 6GT2 091-4LN10 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* 2 m = 6GT2 891-4JH20 Reader connector 90° angled 5 m = 6GT2 891-4JH50 Reader connector 90° angled 10 m = 6GT2 891-4JN10 Reader connector 90° angled + RF120C 6GT2 002-0LA00 Reader powered through connection cable RF210R (6GT2 821-1AC10) RF220R (6GT2 821-2AC10) RF260R (6GT2 821-6AC10) RF240R (6GT2 821-4AC10) RF250R (6GT2 821-5AC10) Opt. Splitter w/ D5, D6 only (6GT2 690-0AC00) RF290R (6GT2 821-0AC12) SIMATIC Ident Configuration Guide Up to 3 x RF120C modules per S7-1200 rack ANT D5 (6GT2 698-5AA10) ANT D6 (6GT2 698-5AB00) ANT D10 (6GT2 698-5AF00) ANT D1 (6GT2 698-5AC00) RF210M (6GT2 823-0AA00) + RF280R (6GT2 821-8AC10) PROFIBUS + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) A maximum of 2 readers may be connected +RF166C to RF2x0R 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 + * Cable improper for RF290R usage due to length limitation of 20 m D428 (6GT2 600-4AK00-0AX0) D528 (6GT2600-5AK00) D425 (6GT2 600-4AG00) D525 (6GT2 600-4AB00) D422 (6GT2 600-4AF00) D522 (6GT2 600-5AF00) D522 (6GT2 600-5AF00-0AX0) D421 (6GT2 600-4AE00) D521 (6GT2 600-5AE00) Tags D423 (6GT2 600-4AA00) D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00) D127 (6GT2 600-4AF00) D117 (6GT2 398-1CF00) D165 (6GT2 600-1AB00-0AX0) D261 (6GT2 600-1AA01-0AX0) D139 (6GT2 600-0AA10) D339 (6GT2 600-3AA10) D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00) D526 (6GT2 600-5AH00) D160 (6GT2 600-0AB10) D460 (6GT2 600-4AB00) D560 (6GT2600-5AB00) D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00) D524 (6GT2 600-5AC00) ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 8 (6GT2 398-1CF10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) Edition: July 2022 RF200 System Interfaces 18 RS232 Binary based protocol or Scanmode ++ Reader with external power supply at Y-cable RF260R (6GT2 821-6AC40) RF240R (6GT2 821-4AC40) RS232 / ASCII Simple text based protocol RS 232 cable for RF2x0R 5 m = 6GT2 891-4KH50 Extension cables: 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 1 Reader per COM port may be connected ++ Wide-Range power supply + 5 m cable 6GT2 898-0ACxx + 6GT2 491-1HH50 Reader with external power supply at Y-cable RF250R (6GT2 821-5AC40) RF290R (6GT2 821-0AC12) RS 232 cable for RF2x0R 5 m = 6GT2 891-4KH50 Extension cables: 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 1 Reader per COM port may be connected Wide-Range power supply + 5 m cable 6GT2 898-0ACxx + 6GT2 491-1HH50 Opt. Splitter w/ D5, D6 only (6GT2 690-0AC00) SIMATIC Ident Configuration Guide ANT D5 (6GT2 698-5AA10) ANT D6 (6GT2 698-5AB00) ANT D10 (6GT2 698-5AF00) ANT D1 (6GT2 698-5AC00) + optional antenna cables 10 m = 6GT2691-0CN10 7.2 m extension = 6GT2691-0DH72 RF280R (6GT2 821-8AC40) + *do not use with D10 ; do not use with Splitter D428 (6GT2 600-4AK00-0AX0) D528 (6GT2600-5AK00) D425 (6GT2 600-4AG00) D525 (6GT2 600-4AB00) D422 (6GT2 600-4AF00) D522 (6GT2 600-5AF00) D522 (6GT2 600-5AF00-0AX0) D421 (6GT2 600-4AE00) D521 (6GT2 600-5AE00) Tags D423 (6GT2 600-4AA00) D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00) D127 (6GT2 600-4AF00) D117 (6GT2 398-1CF00) D165 (6GT2 600-1AB00-0AX0) D261 (6GT2 600-1AA01-0AX0) D139 (6GT2 600-0AA10) D339 (6GT2 600-3AA10) D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00) D526 (6GT2 600-5AH00) D160 (6GT2 600-0AB10) D460 (6GT2 600-4AB00) D560 (6GT2600-5AB00) D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00) D524 (6GT2 600-5AC00) ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 8 (6GT2 398-1CF10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) Edition: July 2022 Reader powered through connection cable IO-Link: ET 200S via PROFIBUS or PROFINET or S7 PLC + + A maximum of 4 (0*) readers may be connected+ET 200S to RF2x0R IO-Link 5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10 RF210R IO-Link 6GT2 821-1AC32 (8 Byte) 6GT2 821-1BC32 (32 Byte) RF220R IO-Link 6GT2 821-2AC32 (8 Byte) 6GT2 821-2BC32 (32 Byte) RF260R IO-Link 6GT2 821-6AC32 (8 Byte) 6GT2 821-6BC32 (32 Byte) RF200 System Interfaces Electronic module (6ES7 138-4GA50-0AB0) 19 IO-Link: ET 200SP via PROFIBUS or PROFINET or S7 PLC + A maximum of 4 (1**) readers may be connected+ET 200SP to RF2x0R IO-Link 5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10 + ET 200S head module ET 200SP head module Electronic module (6ES7 137-6BD00-0BA0) IO-Link: S7-1200 + A maximum of 4 (1*) readers may be connected +S7-1200 to RF2x0R IO-Link 5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10 + S7-1200 SM1278 IO-Link (6ES7278-4BD32-0XB0) IO-Link: ET 200AL via PROFIBUS or PROFINET IO-Link module (6ES7 147-5JD00-0BA0) Head module PN: 6ES7-157-1AB00-0AB0 PB: 6ES7-157-1AA00-0AB0 SIMATIC Ident Configuration Guide RF240R IO-Link 6GT2 821-4AC32 (8 Byte) 6GT2 821-4BC32 (32 Byte) RF250R IO-Link 6GT2 821-5AC32 (8 Byte) 6GT2 821-5BC32 (32 Byte) IO-Link: ET 200pro via PROFIBUS or PROFINET or S7 PLC + ET 200pro PROFIBUS DP-V1 Interface module ET 200pro PROFINET Interface module Up to 9 x 170C modules per ET 200pro rack ET 200pro PROFINET CPU module IO-Link module (6ES7147-4JD00-0AB0) *) for IO-Link reader of type 32 Byte: Some IO-Link Master permit only one or none reader per module **) in case of using a PROFIBUS head module at ET 200SP, only one 32 Byte reader may be connected +ET 200AL to RF2x0R IO-Link 1.5 m = 3RK1902-4PB15-3AA0 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 + A maximum of 4 readers may be connected +ET 200AL to RF2x0R IO-Link 1.5 m = 3RK1902-4PB15-3AA0 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 + A maximum of 4 (1*) readers may be connected D428 (6GT2 600-4AK00-0AX0) D425 (6GT2 600-4AG00) D422 (6GT2 600-4AF00) D421 (6GT2 600-4AE00) Tags D423 (6GT2 600-4AA00) D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00) D127 (6GT2 600-4AF00) D117 (6GT2 398-1CF00) D165 (6GT2 600-1AB00-0AX0) D261 (6GT2 600-1AA01-0AX0) D139 (6GT2 600-0AA10) D339 (6GT2 600-3AA10) D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00) D160 (6GT2 600-0AB10) D460 (6GT2 600-4AB00) D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00) ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 8 (6GT2 398-1CF10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) Edition: July 2022 RF200 System Interfaces 20SIMATIC Ident Configuration Guide IO-Link: S7-1500 IO-Link: Other Master + + M12 Cables for IP65 Masters 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 Open end Cables for IP20 Masters 5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10 ET 200eco PN (6ES7148-6JD00-0AB0) OR ET 200eco PN (6ES7148-6JA00-0AB0) Reader powered through connection cable RF210R IO-Link 6GT2 821-1AC32 (8 Byte) 6GT2 821-1BC32 (32 Byte) RF220R IO-Link 6GT2 821-2AC32 (8 Byte) 6GT2 821-2BC32 (32 Byte) RF260R IO-Link 6GT2 821-6AC32 (8 Byte) 6GT2 821-6BC32 (32 Byte) RF240R IO-Link 6GT2 821-4AC32 (8 Byte) 6GT2 821-4BC32 (32 Byte) RF250R IO-Link 6GT2 821-5AC32 (8 Byte) 6GT2 821-5BC32 (32 Byte) *) for IO-Link reader of type 32 Byte: Reduced number of reader per module for some types of IO-Link Master + Cables ET 200 eco PN to RF2x0R IO-Link 1.5 m = 3RK1902-4PB15-3AA0 5 m = 6GT2 891-4MH50 10 m = 6GT2 891-4MN10 + A maximum of 4 (0*) readers may be connected A maximum of 4 readers may be connected A maximum of 8 (7*) readers may be connected IO-Link: PROFINET + A maximum of 8 (7*) readers may be connected +S7-1500 to RF2x0R IO-Link 5 m = 6GT2 891-4LH50 10 m = 6GT2 891-4LN10 + S7-1500 CM 8xIO-Link, Electronic module (6ES7547-1JF00-0AB0) According to www.io-link.com see competency-matrix for all available offers ET 200eco PN CM 8x IO-Link, M12-L (6ES7148-6JG00-0BB0) OR D428 (6GT2 600-4AK00-0AX0) D425 (6GT2 600-4AG00) D422 (6GT2 600-4AF00) D421 (6GT2 600-4AE00) Tags D423 (6GT2 600-4AA00) D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00) D127 (6GT2 600-4AF00) D117 (6GT2 398-1CF00) D165 (6GT2 600-1AB00-0AX0) D261 (6GT2 600-1AA01-0AX0) D139 (6GT2 600-0AA10) D339 (6GT2 600-3AA10) D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00) D160 (6GT2 600-0AB10) D460 (6GT2 600-4AB00) D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00) ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 8 (6GT2 398-1CF10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) Edition: July 2022 21 RF310R RS422 6GT2801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) 6GT2 801-1BA20-0AX1 (Scanmode) Integrated YES 1-23/ 26 (0.04-0.91/ 1.02) 2-18/ 21 (0.08-0.71/ 0.83) 2-36/ 41 (0.08-1.42/ 1.61) 2-47/ 53 (0.08-1.85/ 2.09) 2-60/68 (0.08-2.36/ 2.68) 2-45/ 60 (0.08-1.77./ 2.36) RF340R RS422 6GT2801-2BA10 6GT2801-2BA10-0AX2 (Ex) Integrated YES 1-20/ 25 (0.04-0.79/ 0.98) 2-20/ 24 (0.08-0.79/ 0.91) 2-50/ 60 (0.08-1.97/ 2.28) 2-60/ 75 (0.08-2.36/ 2.95) 2-65/ 85 (0.08-2.56/ 3.35) 5-60/ 80 (0.20-2.36/ 3.15) 5-80/ 100 (0.20-3.15/ 3.94) RF350R ANT 1 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CB00 (ANT 1) YES 1-30/ 40 (0.04-1.18/ 1.46) 2-25/ 30 (0.08-0.98/ 1.18) 2-55/ 70 (0.08-2.16/ 2.76) 2-65/ 85 (0.08-2,56/ 3.35) 2-75/ 100 (0.08-2.95./ 3.94) 5-65/ 85 (0.20-2.56/ 3.35) 5-90/ 110 (0.20-3.54/ 4.33) RF350R ANT 3 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD40-0AX0 (ANT 3) NO 1-16 / 20 (0.04-0.59/ 0.71) 1-16 / 20 (0.04-0.63/ 0.79) 2-32/ 40 (0.08-1.26/ 1.57) 2-35/ 42 (0.08-1.38/ 1.65) RF350R ANT 3S RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD60-0AX0 (ANT 3S) NO RF350R ANT 8 RS422 6GT2398-1CF10 6GT2398-1CF00 NO Accessories Spacer (6GT2 690-0AK00) Mounting cover (6GT2 690-0AE00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder: (short: 6GT2 090-0QA00) (long: 6GT2 090-0QA00- 0AX3) Cover for holder: (6GT2 090-0QB00) All Purpose Support (6GT2 590-0QA00) 55 x 75 x 30 75 x 75 x 41 75 x 75 x 20 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 RF320T 6GT2 800-1CA00 20 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67/IPX9K RF340T 20 byte EEPROM + 6GT2 800-4BB00 8 kbyte FRAM 6GT2 800-5BB00 32 kByte FRAM -40°C to 85°C 48 x 25 x 15 IP67/IPX9K RF350T 6GT2 800-5BD00 20 byte EEPROM 32 kbyte FRAM -40°C to 85°C 50 x 50 x 20 IP68 RF360T 20 byte EEPROM + 6GT2 800-4AC00 8 kbyte FRAM 6GT2 800-5AC00 32 kbyte FRAM RF370T 20 Byte EEPROM + 6GT2 800-5BE00 32 kbyte FRAM 6GT2 800-6BE00 64 kbyte FRAM -40°C to 85°C 75 x 75 x 41 IP68 RF380T 6GT2 800-5DA00 20 byte EEPROM 32 kbyte FRAM -40°C to 85°C 85.8 x 54.1 x 2.5 IP67 --40°C to 220°C Ø 114 x 83 IP68 Suitable for Dynamic Operation RF330T 6GT2 800-5BA00 20 byte EEPROM 32 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/IPX9K RF300 Family Matrix (RF300 Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating Antennas Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) Edition: July 2022 22 RF350R ANT 12 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DC10 (ANT 12) *) NO RF350R ANT 18 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DA10 (ANT 18) *) NO 1-10/ 13 (0.04-0.39/ 0.51) 1-11/ 13 (0.04-0.43/ 0.51) 1-18/ 22 (0.04-0.71/ 0.87) RF350R ANT 30 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DD10 (ANT 30) NO 1-15/ 20 (0.04-0.59/ 0.79) 2-15/ 18 (0.08-0.59/ 0.71) 1-25/ 30 (0.04-0.98/ 1.1 8) 0-35/ 40 (0-1.18/ 1.57) 2-32/ 38 (0.08-1.26/ 1.5) RF360R Ethernet 6GT2801-5BA30 Integrated 141 x 80 x 42 YES 1-20/ 25 (0.04-0.79/ 0.98) 2-18/ 23 (0.08-0.71/ 0.91) 2-50/ 58 (0.04-1.97/ 2.28) 2-60/ 75 (0.08-2.36/ 2.95) 2-65/ 85 (0.08-2.56/ 3.35) 5-60/ 80 (0.20-2.36/ 3.15) 5-80/ 100 (0.20-3.15/ 3.94) RF380R RS422, RS232 6GT2801-3BA10 6GT2801-3BA10-0AX2 (Ex) Integrated 160 x 96 x 41 YES 2-45/ 60 (0.08-1.77/ 2.36) 5-45/ 48 (0.2-1.77/ 1.89) 2-80/ 105 (0.08-3.15/ 4.13) 2-100/ 125 (0.08-3.94/ 4.92) 2-120/ 150 (0.08-4.72/ 5.91) 5-100/ 135 (0.20-3.94/ 5.31) 5-125/ 160 (0.20-4.92/ 6.30) Accessories Spacer (6GT2 690-0AK00) Mounting cover (6GT2 690-0AE00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder: (short: 6GT2 090-0QA00) (long: 6GT2 090-0QA00- 0AX3) Cover for holder: (6GT2 090-0QB00) All Purpose Support (6GT2 590-0QA00) RF320T 6GT2 800-1CA00 20 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67/IPX9K RF340T 20 byte EEPROM + 6GT2 800-4BB00 8 kbyte FRAM 6GT2 800-5BB00 32 kByte FRAM -40°C to 85°C 48 x 25 x 15 IP67/IPX9K RF350T 6GT2 800-5BD00 20 byte EEPROM 32 kbyte FRAM -40°C to 85°C 50 x 50 x 20 IP68 RF360T 20 byte EEPROM + 6GT2 800-4AC00 8 kbyte FRAM 6GT2 800-5AC00 32 kbyte FRAM RF370T 20 Byte EEPROM + 6GT2 800-5BE00 32 kbyte FRAM 6GT2 800-6BE00 64 kbyte FRAM -40°C to 85°C 75 x 75 x 41 IP68 RF380T 6GT2 800-5DA00 20 byte EEPROM 32 kbyte FRAM -40°C to 85°C 85.8 x 54.1 x 2.5 IP67 --40°C to 220°C Ø 114 x 83 IP68 Ø18 x 40 Ø30 x 40 Suitable for Dynamic Operation RF330T 6GT2 800-5BA00 20 byte EEPROM 32 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/IPX9K SIMATIC Ident Configuration Guide Ø12 x 40 RF300 Family Matrix (RF300 Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating Antennas Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) * antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) RF310R RS422 6GT2801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) 6GT2 801-1BA20-0AX1 (Scanmode) Integrated 2-90/ 102 (0.08-3.54/ 4.02) 2-74/ 83 (0.08-2.91/ 3.27) 2-93/ 105 (0.08-3.66/ 4.1) 2-80/ 90 (0.08-3.15/ 3.54) 2-104/ 115 (0.08-4.09/ 4.53) 1-39/ 44 (0.04-1.54/ 1.73) 1-32/ 38 (0.08-1.26/ 1.50) RF340R RS422 6GT2801-2BA10 6GT2801-2BA10-0AX2 (Ex) Integrated 15-120/ 140 (0.59-4.72/ 5.51) 40-100/ 120 (1.57-3.93/ 4.72) 5-110/ 140 (0.20-4.33/ 5.51) 10-100/ 115 (0.39-3.94/ 4.53) 2-100/ 130 (0.08-3.93/ 5.12) 2-35/ 60 (0.08-1.38/ 2.36) 2-25/ 40 (0.08-0.98/ 1.57) RF350R ANT 1 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CB00 (ANT 1) 5-100/ 120 (0.20-3.94/ 4.72) 5-80/ 95 (0.20-3.15/ 3.74) 5-110/ 140 (0.20-4.33/ 5.51) 5-95/ 115 (0.20-3.74/ 4.53) 2-110/ 135 (0.08-4.33/ 5.31) 2-35/ 60 (0.08-1.38/ 2.36) 2-32/ 38 (0.08-1.26/ 1.50) RF350R ANT 3 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD40-0AX0 (ANT 3) 1-28/ 35 (0.04-1.10/ 1.38) 1-20/ 28 (0.04-0.79/ 1.10) RF350R ANT 3S RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD60-0AX0 (ANT 3S) RF350R ANT 8 RS422 6GT2398-1CF10 6GT2398-1CF00 Accessories Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) Antennas 23 55 x 75 x 30 75 x 75 x 41 75 x 75 x 20 RF300 Family Matrix (ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating 23 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 D200 6GT2 600-1AD00 -0AX0 256 byte EEPROM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D400 6GT2 600-4AD00 2 kbyte FRAM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D165 6GT2 600-1AB00-0AX0 112 byte EEPROM -25°C to 85°C 86 x 54 x 0.3 IP65 D261 6GT2 600-1AA01-0AX0 256 byte EEPROM -25°C to 85°C 55 x 55 x 0.3 IP65 -40°C to 175°C Ø 16 x 3 IP68/IPx9K D160 6GT2 600-0AB10 112 byte EEPROM -40°C to 100°C Ø 16 x 3 IP67/IPx9K D460 6GT2 600-4AB00 2 kbyte FRAM D100 6GT2 600-0AD10 112 byte EEPROM -25°C to 80°C 85,6 x 54 x 0.9 IP68 Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) RF350R ANT 12 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DC10 (ANT 12) *) 0-8/ 12 (0-0.31/ 0.47) 1-8/ 10 (0.04-0.31/ 0.39) RF350R ANT 18 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DA10 (ANT 18) *) 1-18/ 20 (0.04-0.71/ 0.79) 1-12/ 16 (0.04-0.47/ 0.63) RF350R ANT 30 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DD10 (ANT 30) 1-24/ 28 (0.04-0.94/ 1.10) 1-18/ 20 (0.04-0.71/ 0.79) RF360R Ethernet 6GT2801-5BA30 Integrated 141 x 80 x 42 5-110/ 140 (0.20-4.33/ 5.51) 10-100/ 115 (0.39-3.94/ 4.5pass3) 2-100/ 125 (0.08-3.94/ 4.92) RF380R RS422, RS232 6GT2801-3BA10 6GT2801-3BA10-0AX2 (Ex) Integrated 160 x 96 x 41 10-170/ 200 (0.39-6.69/ 7.87) 20-120/ 160 (0.79-4.72/ 6.30) 10-170/ 210 (0.39-6.69/ 8.27) 20-150/195 (0.79-5.90/ 7.67) 10-165/ 185 (0.39-4.50/ 7.28) 2-64/ 80 (0.08-2.52/ 3.15) 2-65/ 90 (0.08-2.56/ 3.54) RF382R RS422, RS232 6GT2801-3AB20-0AX0 Integrated 160 x 96 x 41 35-50/ 65 (1.38-1.97/ 2.56) 35-50/ 60 (1.38-1.97/ 2.36) Accessories Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 2424 Ø30 x 40 SIMATIC Ident Configuration Guide AntennasRF300 Family Matrix (ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating D200 6GT2 600-1AD00 -0AX0 256 byte EEPROM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D400 6GT2 600-4AD00 2 kbyte FRAM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D165 6GT2 600-1AB00-0AX0 112 byte EEPROM -25°C to 85°C 86 x 54 x 0.3 IP65 D261 6GT2 600-1AA01-0AX0 256 byte EEPROM -25°C to 85°C 55 x 55 x 0.3 IP65 -40°C to 175°C Ø 16 x 3 IP68/IPx9K D160 6GT2 600-0AB10 112 byte EEPROM -40°C to 100°C Ø 16 x 3 IP67/IPx9K D460 6GT2 600-4AB00 2 kbyte FRAM D100 6GT2 600-0AD10 112 byte EEPROM -25°C to 80°C 85,6 x 54 x 0.9 IP68 * antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Ø18 x 40 Ø12 x 40 Edition: July 2022 RF310R RS422 6GT2801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) 6GT2 801-1BA20-0AX1 (Scanmode) Integrated 2-64/ 72 (0.08-2.52/ 2.83) 2-64/ 72 (0.08-2.52/ 2.83) 1-68/ 75 (0.04-2.68/ 2.95) RF340R RS422 6GT2801-2BA10 6GT2801-2BA10-0AX2 (Ex) Integrated 2-60/ 75 (0.08-2.36/ 2.95) 2-55/ 70 (0.08-2.17/ 2.76) 2-55/ 70 (0.08-2.17/ 2.76) RF350R ANT 1 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CB00 (ANT 1) 2-65/ 85 (0.08-2.56/ 3.35) 2-66/ 78 (0.08-2.60/ 3.07) 2-75/ 88 (0.08-2.95/ 3.46) RF350R ANT 3 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD40-0AX0 (ANT 3) 1-11/18 (0.04-0.43/ 0.71) 1-35/ 42 (0.04-1.38/ 1.65) 1-22/ 32 (0-0.04/ 1.26) 1-40/ 48 (0.04-1.57/ 1.89) RF350R ANT 3S RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD60-0AX0 (ANT 3S) 0-2/ 3 (0.0-0.08/ 0.12) 0-2/ 3 (0-0.08/ 0.12) 0-4/ 5 (0-0.16/ 0.20) RF350R ANT 8 RS422 6GT2398-1CF10 6GT2398-1CF00 0-4/5 (0.0-0.16/0.19) 0-4/5 (0.0-0.16/0.19) 0-3/4 (0.0-0.12/0.16) Accessories Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 25 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) 55 x 75 x 30 75 x 75 x 41 75 x 75 x 20 Antennas 25 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 D422 6GT2 600-4AF00 2 kbyte FRAM -40°C to 100°C Ø20 x 6 IP68 D127 6GT2 600-0AF00 112 byte EEPROM -40°C to 125°C Ø 6 x 5.8 IP68/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D421 6GT2 600-4AE00 2 kbyte FRAM D324 6GT2 600-3AC00 992 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67 D424 6GT2 600-4AC00 2 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K D124 6GT2 600-0AC10 112 byte EEPROM -40°C to 180°C Ø 27 x 4 IP68/ IPx9K RF300 Family Matrix (ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating -40°C to 125°C Ø4 x 5.2 IP68 IPx9K D117 6GT2 600-0AG00 112 byte EEPROM Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) RF350R ANT 12 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DC10 (ANT 12) *) 0-2/ 3 (0.0-0.08/ 0.12) 0-3/ 4 (0-0.12/ 0.16) 0-3/ 5 (0-0.12/ 0.20) RF350R ANT 18 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DA10 (ANT 18) *) 0-5/ 6 (0.-0.20/ 0.24) 0-5/ 6 (0.-0.20/ 0.24) 0-4/ 6 (0-0.24/ 0.31) 1-10/ 13 (0.04-0.39/ 0.51) 2-24/ 28 (0.08-0.94/ 1.10) 1-22/ 28 (0.04-0.87/ 1.1) 1-27/ 35 (0.04-1.06/ 1.38) RF350R ANT 30 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DD10 (ANT 30) 1-14/ 16 (0.04-0.55/ 0.63) 1-35/ 40 (0.04-1.38/ 1.57) 1-35/ 40 (0.04-1.38/ 1.57) 1-45/ 50 (0.04-1.77/ 1.97) RF360R Ethernet 6GT2801-5BA30 Integrated 141 x 80 x 42 2-60/ 75 (0.08-2.36/ 2.95) 2-55/ 70 (0.08-2.17/ 2.76) 2-55/ 70 (0.08-2.17/ 2.76) RF380R RS422, RS232 6GT2801-3BA10 6GT2801-3BA10-0AX2 (Ex) Integrated 160 x 96 x 41 1-120/ 140 (0.04-4.72/ 5.51) 2-96/ 120 (0.08-3.78/ 4.72) 2-120/ 140 (0.08-4.72/ 5.51) RF382R RS422, RS232 6GT2801-3AB20-0AX0 Integrated 160 x 96 x 41 40-65/ 75 (1.57-2.56/ 2.95) 40-65/ 75 (1.57-2.56/ 2.95) 40-65/ 75 (1.57-2.56/ 2.95) Accessories Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AK00) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 2626 Ø30 x 40 SIMATIC Ident Configuration Guide Antennas D422 6GT2 600-4AF00 2 kbyte FRAM -40°C to 100°C Ø20 x 6 IP68 D127 6GT2 600-0AF00 112 byte EEPROM -40°C to 125°C Ø 6 x 5.8 IP68/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K D421 6GT2 600-4AE00 2 kbyte FRAM D124 6GT2 600-0AC10 112 byte EEPROM -40°C to 180°C Ø 27 x 4 IP68/ IPx9K D324 6GT2 600-3AC00 992 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67 D424 6GT2 600-4AC00 2 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K RF300 Family Matrix (ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating -40°C to 125°C Ø4 x 5.2 IP68 IPx9K D117 6GT2 600-0AG00 112 byte EEPROM * antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Ø12 x 40 Ø18 x 40 Edition: July 2022 RF310R RS422 6GT2801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) 6GT2 801-1BA20-0AX1 (Scanmode) Integrated 2-65/ 73 (0.08-2.56/ 2.87) 5-75/ 90 (0.2-2.95/ 3.54) 2-35/ 46 (0.08-1.38/ 1.81) 1-22/ 25 (0.04-0.87/ 0.98) 1-40/ 45 (0.08-1.57/ 1.77) 5-96/ 109 (0.20-3.78/ 4.29) 5-74/ 84 (0.20-2.91/ 3.31) RF340R RS422 6GT2801-2BA10 6GT2801-2BA10-0AX2 (Ex) Integrated 2-85/ 110 (0.08-3.34/ 4.33) 1-80/ 100 (0.04-3.15/ 3.94) 5-40/ 48 (0.2-1.57/ 1.89) 2-20/ 30 (0.08-0.79/ 1.18) 2-40/ 50 (0.08-1.57/ 1.97) 5-80/ 110 (0.20-3.15/ 4.33) 5-75/ 85 (0.20-2.95/ 3.35) RF350R ANT 1 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CB00 (ANT 1) 2-90/ 120 (0.08-3.54/ 4.72) 2-85/ 95 (0.08-3.35/ 3.74) 10-48/ 60 (0.39-1.89/ 2.36) 2-23/ 32 (0.08-0.91/ 1.26) 2-40/ 50 (0.08-1.57/ 1.97) 5-85/ 115 (0.20-3.35/ 4.53) 5-90/ 105 (0.20-3.54/ 4.13) RF350R ANT 3 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD40-0AX0 (ANT 3) 5-20/ 30 (0.2-0.79/ 1.18) 2-18/ 22 (0.08-0.71/ 0.87) 2-28/ 30 (0.08-1.10/ 1.18) RF350R ANT 3S RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD60-0AX0 (ANT 3S) RF350R ANT 8 RS422 6GT2398-1CF10 6GT2398-1CF00 Accessories Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) Mounting cover (6GT2 690-0AE00) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 27 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) 55 x 75 x 30 75 x 75 x 41 75 x 75 x 20 27 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 D423 6GT2 600-4AA00 2 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/ IPx9K D425 6GT2 600-4AG00 2 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K AntennasRF300 Family Matrix (ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating D426 6GT2 600-4AH00 2 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D126 6GT2 600-0AE00 112 byte EEPROM -40°C to 100°C Ø 50 x 3.6 IP68 D428 6GT2 600-4AK00-0AX0 2 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D139 6GT2 600-0AA10 112 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K D339 6GT2600-3AA10 992 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) RF350R ANT 12 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DC10 (ANT 12) *) 1-10/ 17 (0.04-0.39/ 0.67) RF350R ANT 18 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DA10 (ANT 18) *) 1-10/ 14 (0.04-0.39/ 0.55) 1-15/ 20 (0.04-0.59/ 0.79) RF350R ANT 30 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DD10 (ANT 30) 1-42/ 50 (0-1.65/ 1.97) 1-45/ 48 (0.04-1.77/ 1.89) 5-22/ 28 (0.2-0.87/ 1.10) 1-15/ 20 (0.04-0.59/ 0.79) 1-25/ 28 (0.04-0.98/ 1.10) RF360R Ethernet 6GT2801-5BA30 Integrated 141 x 80 x 42 2-85/ 110 (0.08-3.35/ 4.33) 1-80/ 100 (0.04-3.15/ 3.94) 5-42/ 50 (0.2-1.65/1.97) 5-80/ 110 (0.2-3.15/ 4.33) 5-75/ 85 (0.2-2.95/ 3.35) RF380R RS422, RS232 6GT2801-3BA10 6GT2801-3BA10-0AX2 (Ex) Integrated 160 x 96 x 41 2-145/ 190 (0.08-5.71/ 7.48) 2-155/ 195 (0.08-6.1/ 7.68) 5-75/ /83 (0.2-2.95/ 3.27) 2-35/ 50 (0.08-1.38/ 1.97) 2-70/ 95 (0.08-2.76/ 3.74) 5-200/ 230 (0.20-7.87/ 9.05) 17-160/ 180 (0.67-6.30/ 7.09) RF382R RS422, RS232 6GT2801-3AB20-0AX0 Integrated 160 x 96 x 41 Accessories Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AL00) Mounting cover (6GT2 690-0AE00) Spacer (6GT2 690-0AA00) Mount for quick tag exchange (6GT2 690-0AH00 - long) (6GT2 690-0AH10 short) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 2828 Ø30 x 40 SIMATIC Ident Configuration Guide D423 6GT2 600-4AA00 2 kbyte FRAM -40°C to 100°C Ø 30 x 8 IP68/ IPx9K D425 6GT2 600-4AG00 2 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68/ IPx9K AntennasRF300 Family Matrix (ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating D426 6GT2 600-4AH00 2 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D126 6GT2 600-0AE00 112 byte EEPROM -40°C to 100°C Ø 50 x 3.6 IP68 D428 6GT2 600-4AK00-0AX0 2 kbyte FRAM -40°C to 125°C Ø 24 x 20 IP68/ IPx9K D139 6GT2 600-0AA10 112 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K D339 6GT2600-3AA10 992 byte EEPROM -40°C to 220°C Ø 85 x 15 IP68/IPx9K * antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Ø12 x 40 Ø18 x 40 Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) RF310R RS422 6GT2801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) Integrated 1-70/78 (0.04-2.76/ 3.07) 1-22/25 (0.04-0.87/ 0.98) 5-80/90 (0.2-3.14/ 3.54) 1-43/48 (0.04-1.69/ 1.89) 1-32/38 (0.04-1.26/ 1.5) RF340R RS422 6GT2801-2BA10 6GT2801-2BA10-0AX2 (Ex) Integrated 2-55/70 (0.08-2.16/ 2.76) 2-20/30 (0.08-0.79/ 1.18) 1-80/100 (0.04-3.15/ 3.94) 2-40/50 (0.08-1.57/ 1.97) 2-25/40 (0.08-0.98/ 1.57) RF350R ANT 1 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CB00 (ANT 1) 2-65/85 (0.08-2.56/ 3.35) 2-25/35 (0.08-0.98/ 1.38) 1-85/105 (0.04-3.35/ 4.13) 2-35/50 (0.08-1.38/ 1.97) 2-32/38 (0.08-1.26/ 1.5) RF350R ANT 3 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD40-0AX0 (ANT 3) 1-19/22 (0.04-0.75/ 0.87) 5-46/50 (0.2-1.81/ 1.97) 2-21/24 (0.08-0.83/ 0.94) 2-24/26 (0.08-0.94/ 1.02) 1-20/28 (0.04-0.79/ 1.1) RF350R ANT 3S RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD60-0AX0 (ANT 3S) 0-3/4 (0-0.12/ 0.16) RF350R ANT 8 RS422 6GT2398-1CF10 6GT2398-1CF00 0-3/4 (0.0-0.12/0.16) Accessories Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 29 55 x 75 x 30 75 x 75 x 41 75 x 75 x 20 29 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 -40°C to 125°C Ø 24 x 20 IP68/IPx9K D528 6GT2 600-5AK00 8 kByte FRAM D525 6GT2 600-5AG00 8 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68 / IPx9k D526 6GT2 600-5AH00 8 kByte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D522 6GT2 600-5AF00 8 kByte FRAM -40°C to 100°C Ø 20 x 6 IP68 D521 6GT2 600-5AE00 8 kByte FRAM -40°C to 100°C Ø 10 x 4.5 IP67/IPx9K D524 6GT2 600-5AC00 8 kByte FRAM -40°C to 100°C Ø 27 x 4 IP67 / IPx9k -40°C to 90°C Ø 16 x 3 IP68/IPx9K D560 6GT2 600-5AB00 8 kByte FRAM AntennasRF300 Family Matrix (8 KB ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating * antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Edition: July 2022 Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) 3030SIMATIC Ident Configuration Guide RF350R ANT 12 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DC10 (ANT 12) *) 0-3/5 (0-0.12/ 0.2) 1-10/17 (0.04-0.40/ 0.67) 1-8/10 (0.04-0.31/ 0.39) RF350R ANT 18 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DA10 (ANT 18) *) 0-6/8 (0-0.24/ 0.31) 1-10/13 (0.04-0.39/ 0.51) 1-27/35 (0.04-1.06/ 1.38) 1-10/14 (0.04-0.39/ 0.55) 1-15/20 (0.04-0.59/ 0.79) 1-12/16 (0.04-0.47/ 0.63) RF350R ANT 30 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DD10 (ANT 30) 1-15/ 18 (0.04-0.59/ 0.70) 0-45/ 50 (0-1.77/ 1.97) 1-15/ 20 (0.04-0.59/ 0.79) 0-45/ 48 (0-1.77/ 1.89) 1-25/ 28 (0.04-0.98/ 1.10) 1-18/ 20 (0.04-0.71/ 0.79) RF360R Ethernet 6GT2801-5BA30 Integrated 141 x 80 x 42 2-55/ 70 (0.08-2.17/ 2.76) 1-80/ 100 (0.04-3.15/ 3.94) RF380R RS422, RS232 6GT2801-3BA10 6GT2801-3BA10-0AX2 (Ex) Integrated 160 x 96 x 41 2-115/ 130 (0.08-4.52/ 5.12) 2-35/ 50 (0.08-1.38/ 1.97) 2-155/ 195 (0.08-6.10/ 7.68) 2-70/ 95 (0.08-2.76/ 3.74) 2-65/ 90 (0.08-2.56/ 3.54) Accessories Spacer (6GT2 690-0AK00) Spacer (6GT2 690-0AL00) Spacer (6GT2 690-0AG00) Angle pattern body (6GT2690-0AN00) Ø30 x 40 -40°C to 125°C Ø 24 x 20 IP68/IPx9K D528 6GT2 600-5AK00 8 kByte FRAM D525 6GT2 600-5AG00 8 kbyte FRAM -40°C to 125°C Ø 24 x 10 IP68 / IPx9k D526 6GT2 600-5AH00 8 kByte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D522 6GT2 600-5AF00 8 kByte FRAM -40°C to 100°C Ø 20 x 6 IP68 D521 6GT2 600-5AE00 8 kByte FRAM -40°C to 100°C Ø 10 x 4.5 IP67/IPx9K D524 6GT2 600-5AC00 8 kByte FRAM -40°C to 100°C Ø 27 x 4 IP67 / IPx9k -40°C to 90°C Ø 16 x 3 IP68/IPx9K D560 6GT2 600-5AB00 8 kByte FRAM AntennasRF300 Family Matrix (8 KB ISO Tags) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating Ø12 x 40 Ø18 x 40 Edition: July 2022 RF310R RS422 6GT2801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) Integrated 2-30/ 43 (0.08-1.18/ 1.69) 2-40/ 60 (0.08-1.57/ 2.36) 2-35/ 36 (0.08-1.37/ 1.42) RF340R RS422 6GT2801-2BA10 6GT2801-2BA10-0AX2 (Ex) Integrated 5-50/ 65 (0.2-1.97/ 2.56) 10-50/ 65 (0.39-1.97/ 2.56) 2-35/ 45 (0.08-1.37/ 1.77) RF350R ANT 1 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CB00 (ANT 1) 10-50/ 60 (0.39-1.97/ 2.36) 20-50/ 65 (0.79-1.97/ 2.56) 2-35/ 45 (0.08-1.37/ 1.77) RF350R ANT 3 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD40-0AX0 (ANT 3) 1-15/ 16 (0.04-0.59/ 0.63) RF350R ANT 3S RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1CD60-0AX0 (ANT 3S) RF350R ANT 8 RS422 6GT2398-1CF10 6GT2398-1CF00 Accessories Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AK00) Antennas 31 55 x 75 x 30 75 x 75 x 41 75 x 75 x 20 RF300 Family Matrix (MOBY E compatibility) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating 31 28 x 50 x 10 SIMATIC Ident Configuration Guide 28 x 50 x 10 E623 6GT2 300-0CD00 752 byte EEPROM E624 6GT2 300-0CE00 752 byte EEPROM E611 6GT2 300-0BB00 752 byte EEPROM -40°C to 85°C 86 x 54 x 2.5 IP67 E600 6GT2 300-0AA00 752 byte EEPROM -25°C to 60°C 86 x 54 x 0.76 IP68 -40°C to 150°C Ø 27 x 4 IP67/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) * antennas also available with 0.6 m antenna cable: use 0.6 m antenna cable 6GT2391-0AE60 together with 6GT2398-1DC10 (ANT12) or 6GT2398-1DA00 (ANT18) Edition: July 2022 RF350R ANT 12 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DC10 (ANT 12) *) 0-3/ 5 (0-0.12/ 0.20) RF350R ANT 18 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DA10 (ANT 18) *) 0-6/ 8 (0-0.24/ 0.31) 2-10/ 15 (0.08-0.40/ 0.59) RF350R ANT 30 RS422 6GT2801-4BA10 6GT2801-4BA10-0AX2 (Ex) 6GT2 398-1DD10 (ANT 30) 1-20/ 24 (0.04-0.79/ 0.94) RF380R RS422, RS232 6GT2801-3BA10 6GT2801-3BA10-0AX2 (Ex) Integrated 160 x 96 x 41 10-80/ 95 (0.39-3.15/ 3.74) 10-115/ 135 (0.39-4.53/ 5.31) 5-50/ 60 (0.20-1.97/ 2.36) Accessories Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Holder (6GT2 390-0AA00) 20 mm spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 690-0AK00) Antennas 32 RF300 Family Matrix (MOBY E compatibility) 13.56 MHz Passive Tags Operational Temperature Range Dimensions( L x W x D) mm Ingress Protection (IP) Rating 32SIMATIC Ident Configuration Guide E623 6GT2 300-0CD00 752 byte EEPROM E624 6GT2 300-0CE00 752 byte EEPROM E600 6GT2 300-0AA00 752 byte EEPROM -25°C to 60°C 86 x 54 x 0.76 IP68 E611 6GT2 300-0BB00 752 byte EEPROM -40°C to 85°C 86 x 54 x 2.5 IP67 Ø30 x 40 -40°C to 150°C Ø 27 x 4 IP67/ IPx9K -40°C to 100°C Ø10 x 4.5 IP67/ IPx9K Operating Distance Range (mm) / Maximum Distance for Stationary Tag (mm) Operating Distance Range (inch) / Maximum Distance for Stationary Tag (inch) Ø12 x 40 Ø18 x 40 Edition: July 2022 33 RF300 System Interfaces SIMATIC Ident Configuration Guide Reader with external power supply RF360R 6GT2801-5BA30 PROFINET & OPC UA & TCP/IP Tags RF320T (6GT2 800-1CA00) RF340T (8 kb: 6GT2 800-4BB00) (32 kb: 6GT2 800-5BB00) RF350T (6GT2 800-5BD00) RF360T (8 kb: 6GT2 800-4AC00) (32 kb: 6GT2 800-5AC00) RF370T (32 kb: 6GT2 800-5BE00) (64 kb: 6GT2 800-6BE00) RF380T (6GT2 800-5DA00) RF330T (6GT2 800-5BA00) ISO TAGs D100 6GT2 600-0AD10 D200 6GT2 600-1AD00-0AX0 D400 6GT2 600-4AD00 D124 6GT2 600-0AC10 D324 6GT2 600-3AC00 D424 6GT2 600-4AC00 D524 6GT2 600-5AC00 D126 6GT2 600-0AE00 D426 6GT2 600-4AH00 D526 6GT2 600-5AH00 D139 6GT2 600-0AA10 D339 6GT2 600-3AA10 General host application as a, XML client b, Off-the-shelf third-party RFID Middleware c, OPC UA for AutoID Client Controller Application written in any controller language using Ident library with Ident profile + +Ethernet /PN Cable M12 length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required) Direct connection Ethernet /PN Cable M12 length from 2 to 15 m available e.g. 2 m = 6XV1871-5TH20 Network Connection via Switch IE switch SCALANCE X (6GK5 ) + length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 ++ + Controller Library and Demo-Software on DVD Power supply EU connector 6GT2 898-0AC00 US connector 6GT2 898-0AC20 UK connector 6GT2 898-0AC10 cable 24 V for power supply 5 m = 6GT2 091-0PH50 cable M12 L-coded 180° = 6XV1801-6Dxxx* 90° = 6XV1801-6Gxxx* Cover caps 3RX9 802-0AA00 * More details on page 78 Edition: July 2022 34 RF300 System Interfaces SIMATIC Ident Configuration Guide Reader powered through connection cable RF340R 6GT2 801-2BA10 6GT2801-2BA10-0AX2 (Ex) RF380R 6GT2 801-3BA10 6GT2801-3BA10-0AX2 (Ex) RF350R 6GT2 801 -4BA10, /-4BA10-0AX2 (Ex) +2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled: 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 + PROFINET & OPC UA & Ethernet/IP & TCP/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + Or one Standard sensor Or one Actor A maximum of 1 reader at RF185C, 2 readers at RF186C/CI, 4 readers at RF188C/CI of RF3x0R may be connected RF310R RS422 6GT2 801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) Types of IO-Link IO module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) Tags RF320T (6GT2 800-1CA00) RF340T (8 kb: 6GT2 800-4BB00) (32 kb: 6GT2 800-5BB00) RF350T (6GT2 800-5BD00) RF360T (8 kb: 6GT2 800-4AC00) (32 kb: 6GT2 800-5AC00) RF370T (32 kb: 6GT2 800-5BE00) (64 kb: 6GT2 800-6BE00) RF380T (6GT2 800-5DA00) RF330T (6GT2 800-5BA00) ISO TAGs D100 6GT2 600-0AD10 D200 6GT2 600-1AD00-0AX0 D400 6GT2 600-4AD00 D117 6GT2 600-0AG00 D421 6GT2 600-4AE00 D422 6GT2 600-4AF00 D423 6GT2 600-4AA00 D124 6GT2 600-0AC10 D324 6GT2 600-3AC00 D424 6GT2 600-4AC00 D425 6GT2 600-4AG00 D126 6GT2 600-0AE00 D426 6GT2 600-4AH00 D127 6GT2 600-0AF00 D428 6GT2 600-4AK00-0AX0 D139 6GT2 600-0AA10 D339 6GT2 600-3AA10 D160 6GT2 600-0AB10 D460 6GT2 600-4AB00 D560 6GT2600-5AB00 D261 6GT2 600-1AA01-0AX0 D165 6GT2 600-1AB00-0AX0 ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) Edition: July 2022 35 SIMATIC PLC S7-300 Rack or S7-400 via ET 200M (DP-V1/PN-IO) A maximum of 2 readers may be connected +RF170C to RF3x0R 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 Reader connector 90° angled 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 ET 200pro via PROFIBUS or PROFINET or S7 PLC ++ RF170C Communication Module (6GT2002-0HD01) Connection Block (6GT2002-1HD01) ET 200pro PROFIBUS DP-V1 Interface Modul ET 200pro PROFINET Interface Modul Up to 9 x 170C modules per ET 200pro rack ET 200pro PROFINET CPU module A maximum of 2 Readers may be connected +ASM 475 to RF3x0R 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 And Extension Cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 2 m = 6GT2 891-4JH20 Reader connector 90° angled 5 m = 6GT2 891-4JH50 Reader connector 90° angled 10 m = 6GT2 891-4JN10 Reader connector 90° angled ASM 475 + Front Connector (6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) + + Accessories: Connecting element (6ES7 390-5AA00-0AA0) Terminal element (6ES7 390-5BA00-0AA0) RF300 System Interfaces SIMATIC PLC S7-1200 A maximum of 1 readers may be connected +RF120C to RF3x0R 2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50 10m = 6GT2 091-4LN10 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 2 m = 6GT2 891-4JH20 Reader connector 90° angled 5 m = 6GT2 891-4JH50 Reader connector 90° angled 10 m = 6GT2 891-4JN10 Reader connector 90° angled + RF120C 6GT2 002-0LA00 SIMATIC Ident Configuration Guide Up to 3 x RF120C modules per S7-1200 rack RF310R RS422 6GT2 801-1BA10 6GT2801-1BA10-0AX1 (90°plate) 6GT2801-1BA10-0AX2 (Ex) Reader powered through connection cable RF340R 6GT2 801-2BA10 6GT2801-2BA10-0AX2 (Ex) RF380R 6GT2 801-3BA10 6GT2801-3BA10-0AX2 (Ex) RF350R 6GT2 801 -4BA10, /-4BA10-0AX2 (Ex)PROFIBUS + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) A maximum of 2 readers may be connected +RF166C to RF2x0R 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 Tags RF320T (6GT2 800-1CA00) RF340T (8 kb: 6GT2 800-4BB00) (32 kb: 6GT2 800-5BB00) RF350T (6GT2 800-5BD00) RF360T (8 kb: 6GT2 800-4AC00) (32 kb: 6GT2 800-5AC00) RF370T (32 kb: 6GT2 800-5BE00) (64 kb: 6GT2 800-6BE00) RF380T (6GT2 800-5DA00) RF330T (6GT2 800-5BA00) ISO TAGs D100 6GT2 600-0AD10 D200 6GT2 600-1AD00-0AX0 D400 6GT2 600-4AD00 D117 6GT2 600-0AG00 D421 6GT2 600-4AE00 D422 6GT2 600-4AF00 D423 6GT2 600-4AA00 D124 6GT2 600-0AC10 D324 6GT2 600-3AC00 D424 6GT2 600-4AC00 D425 6GT2 600-4AG00 D126 6GT2 600-0AE00 D426 6GT2 600-4AH00 D127 6GT2 600-0AF00 D428 6GT2 600-4AK00-0AX0 D139 6GT2 600-0AA10 D339 6GT2 600-3AA10 D160 6GT2 600-0AB10 D460 6GT2 600-4AB00 D560 6GT2600-5AB00 D261 6GT2 600-1AA01-0AX0 D165 6GT2 600-1AB00-0AX0 ANT 12 (6GT2398-1DC10 ANT 18 (6GT2398-1DA10) ANT 30 (6GT2398-1DD10) ANT 3 (6GT2 398-1CD40-0AX0) ANT 3S (6GT2 398-1CD60-0AX0) ANT 1 (6GT2 398-1CB00) Edition: July 2022 36 RF310R Scanmode (6GT2 801-1BA20-0AX1) Reader with external power supply RF300 System Interfaces No Driver needed Scanmode; Read only RS232/RS422 RS232 RS422 24VDC IN + Interface Converter (ie. TRP-C06 Trycom IP) + 1 Reader per COM port may be connected Open Wire to RF310R Scanmode 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 24VDC OUT RS422 RS232 RF382R (6GT2 801-3AB20-0AX0) RS232 No Driver needed Scanmode; Read only RS 232 cable for RF382R 5 m = 6GT2 891-4KH50 Extension cables: 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 1 Reader per COM port may be connected ++ Wide-Range power supply + 5 m cable 6GT2 898-0ACxx + 6GT2 491-1HH50 Reader with external power supply at Y-cable SIMATIC Ident Configuration Guide Tags RF320T (6GT2 800-1CA00) RF340T (8 kb: 6GT2 800-4BB00) (32 kb: 6GT2 800-5BB00) RF350T (6GT2 800-5BD00) RF360T (8 kb: 6GT2 800-4AC00) (32 kb: 6GT2 800-5AC00) RF370T (32 kb: 6GT2 800-5BE00) (64 kb: 6GT2 800-6BE00) RF380T (6GT2 800-5DA00) RF330T (6GT2 800-5BA00) ISO TAGs D100 6GT2 600-0AD10 D200 6GT2 600-1AD00-0AX0 D400 6GT2 600-4AD00 D117 6GT2 600-0AG00 D421 6GT2 600-4AE00 D422 6GT2 600-4AF00 D423 6GT2 600-4AA00 D124 6GT2 600-0AC10 D324 6GT2 600-3AC00 D424 6GT2 600-4AC00 D425 6GT2 600-4AG00 D126 6GT2 600-0AE00 D426 6GT2 600-4AH00 D127 6GT2 600-0AF00 D428 6GT2 600-4AK00-0AX0 D139 6GT2 600-0AA10 D339 6GT2 600-3AA10 D160 6GT2 600-0AB10 D460 6GT2 600-4AB00 D560 6GT2600-5AB00 D261 6GT2 600-1AA01-0AX0 D165 6GT2 600-1AB00-0AX0 Edition: July 2022 Integrated 1.2 (47) 0.8 (31) 0.6 (24) 0.4 (16) 0.3 (12) 1 (39) 0.5 (20) 0.4 (16) 0.4 (16) 0.15 (6) 0.2 (8) 0.25 (10) 0.6 (24) 0.4 (16) 0.4 (16) 0.2 (8) 0.2 (8) 0.25 (10) 4.0 (157) 3.0 (118) 3.0 (118) 1.6 (63) 1.8 (71) 3.0 (118) 2.0 (79) 1.4 (55) 1.0 (39) 0.9 (35) 0.8 (31) 1.6 (63) 4.0 (157) 3.0 (118) 2.5 (98) 1.4 (55) 1.6 (63) 3.0 (118) 2.0 (79) 1.6 (63) 1.0 (39) 1.0 (39) 1.0 (39) 1.6 (63) Accessories ** 3-way mounting kit (6GT2 890-2AB10) *** mounting plate (6GT2890-2AC00) Maximum operating distance (m) and maximum operating distance (inch) pay attention to the system manual for range overshoot 37SIMATIC Ident Configuration Guide Operational Temperature Range Dimensions ( L x W x D) mm Ingress Protection (IP) Rating RF615R*** (IP67) (internal antenna used) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) RF610R*** (IP67) (internal antenna used) 6GT2811-6BC10-0AA0 (ETSI) 6GT2811-6BC10-1AA0 (FCC) 6GT2811-6BC10-2AA0 (CMIIT) RF615R*** (IP67) (external antenna used) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) Antennas Antennas: 6GT2 812-0EA00 6GT2 812-0EA01 6GT2 812-2EA00 6GT2 812-2EA01 6GT2 812-1GA08 6GT2 812-0GB08 6GT2 812-0AA00 6GT2 812-0AA01 6GT2 812-2GB08 RF615A, linear, RF615A, linear, RF622A, linear, RF622A, linear, RF642A, linear, RF650A, circular, RF660A, circular, RF660A, circular, RF680A, switchable (ETSI) (FCC, CMIIT) (ETSI) (FCC, CMIIT) (all readers) (all readers) (ETSI) (FCC, CMIIT) , (all readers) 865-868 MHz (ETSI) 902-928 MHz (FCC) Passive Tags (with Gen2 protocol) RF600 Family Matrix Labels 133 x 133 x 45 RF630L 6GT2 810-2AB02-0AX0 128 bits EPC, 64 byte -40°C to 80°C 97 x 27 IP65 -40°C to 80°C 54 x 34 IP65 RF630L 6GT2 810-2AB03 96/240 bits EPC, 64 byte -20°C to 160°C 74 x 27 IP60 RF630L 6GT2 810-2AB04 256 bits EPC, 64 byte -40°C to 85°C 73 x 12.5 IP67 RF630L 6GT2 810-2AC84 448 bits EPC, 256 byte RF622A*** 75 x 75 x 20 313 x 313 x 80 RF660A** 185 x 185 x 45 RF642A** RF650A** RF680A** 198 x 198 x 60 198 x 198 x 60 RF615A*** 52 x 52 x 16 * For detailed size information see technical data RF630L 6GT2 810-2AE82-0AX0 /-0AX1 /-0AX2 /-1AX0 /-2AX0 /-2AX1 128 bits EPC -25°C to 160°C various sizes* IP67 RF630L 6GT2 810-2AE83-1AX0 128 bits EPC -25°C to 130°C 45 x 20 IP67 washable Edition: July 2022 Integrated 0.8 (31) 1 (39) 1.8 (71) 1.0 (39) 1.2 (47) 0.4 (16) 0.25 (9.8) 0.4 (16) 0.25 (9.8) 0.7 (28) 0.5 (20) 0.25 (9.8) 0.5 (20) 0.4 (16) 0.9 (35) 3.5 (138) 3.0 (118) 3.5 (138) 2.0 (79) 4.5 (177) 1.4 (55) 1.6 (63) 3.0 (118) 0.8 (31) 2.5 (98) 3.0 (118) 3.0 (118) 4.5 (177) 1.8 (71) 4.5 (177) 1.6 (63) 1.6 (63) 3.0 (118) 1.0 (39) 2.5 (98) Accessories ** 3-way mounting kit (6GT2 890-2AB10) *** mounting plate (6GT2890-2AC00) Maximum operating distance (m) and maximum operating distance (inch) pay attention to the system manual for range overshoot 38 RF642L 6GT2810-3AC00 (ETSI) 6GT2810-3AC10 (FCC) 448 bit EPC, 256 byte -25°C to 85°C 50 x 22.5 x 1.6 IP68 SIMATIC Ident Configuration Guide Operational Temperature Range Dimensions ( L x W x D) mm Ingress Protection (IP) Rating RF615R*** (IP67) (internal antenna used) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) RF610R*** (IP67) (internal antenna used) 6GT2811-6BC10-0AA0 (ETSI) 6GT2811-6BC10-1AA0 (FCC) 6GT2811-6BC10-2AA0 (CMIIT) RF615R*** (IP67) (external antenna used) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) Antennas 865-868 MHz (ETSI) 902-928 MHz (FCC) Passive Tags (with Gen2 protocol) RF600 Family Matrix Labels 133 x 133 x 45 -40°C to 120°C 75 x 20 IP67 RF630L 6GT2810-2AE81-0AX3 448 bit EPC, 256 Byte -40°C to 230°C 156 x 40 IP67 RF682L 6GT2810-2AG84-0AX0 448 bits EPC, 256 Byte RF622A*** 75 x 75 x 20 313 x 313 x 80 RF660A** 185 x 185 x 45 RF642A** RF650A** RF680A** 198 x 198 x 60 198 x 198 x 60 RF615A*** 52 x 52 x 16 Antennas: 6GT2 812-0EA00 6GT2 812-0EA01 6GT2 812-2EA00 6GT2 812-2EA01 6GT2 812-1GA08 6GT2 812-0GB08 6GT2 812-0AA00 6GT2 812-0AA01 6GT2 812-2GB08 RF615A, linear, RF615A, linear, RF622A, linear, RF622A, linear, RF642A, linear, RF650A, circular, RF660A, circular, RF660A, circular, RF680A, switchable (ETSI) (FCC, CMIIT) (ETSI) (FCC, CMIIT) (all readers) (all readers) (ETSI) (FCC, CMIIT) , (all readers) RF635L 6GT2810-3AC80-1AX0 256 bit EPC, 60 byte -25°C to 80°C 207,4 x 74 IP20 -25°C to 130°C 105 x 25 IP67 RF630L 6GT2810-2AE83-0AX1 448 bit EPC, 256 Byte Edition: July 2022 Integrated 1 (39) 2.5 (98) 0.1 (4) 0.15 (6) 0.2 (7.9) 1.0 (39) 1.2 (47) 0.8 (31) 0.3 (12) 1.0 (39) 0.1 (4) 0.1 (4) 0.2 (8) 0.7 (28) 0.6 (24) 0.4 (16) 0.4 (16) 1.2 (47) 0.1 (4) 0.15 (6) 0.2 (8) 0.9 (35) 0.7 (28) 0.4 (16) 3.0 (118) 4.0 (157) 1 (39) 0.5 (20) 1.4 (55) 3.0 (118) 4.0 (157) 2.5 (98) 1.2 (47) 3.5 (138) 0.25 (8) 0.4 (16) 0.7 (28) 1.6 (63) 1.8 (71) 1.2 (47) 3.0 (118) 4.0 (157) 0.8 (31) 1.0 (39) 1.2 (47) 3.5 (138) 4.0 (157) 2.0 (79) 1.4 (55) 4.0 (157) 0.2 (8) 0.5 (20) 1.2 (47) 1.8 (71) 2.0 (79) 1.2 (47) Accessories ** 3-way mounting kit (6GT2 890-2AB10) *** mounting plate (6GT2890-2AC00) 20 mm Spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 898-2AA00) Mounting cover 6GT2898-5AA00 Retaining bracket 6GT2898-5AB00 Retaining bracket 6GT2890-2AA00 Retaining bracket 6GT2890-2AA00 Operational Temperature Range Dimensions ( L x W x D) mm Ingress Protection (IP) Rating Maximum operating distance (m) and maximum operating distance (inch) pay attention to the system manual for range overshoot 39 Antennas RF630T 6GT2 810-2EC00 (ETSI) 6GT2 810-2EC10 (FCC) 96/240 bit EPC, 64 byte -40°C to 125°C Ø 21x 20 IP68/ IPx9K RF640T 6GT2 810-2DC00 (ETSI) 6GT2 810-2DC10 (FCC) 96/240 bit EPC, 64 byte -40°C to 125°C Ø 50 x 8 IP68/ IPx9K RF610T 6GT2 810-2BB80 96/240 bit EPC, 64 byte -40°C to 85°C 86 x 54 x 0.4 IP67 RF620T 6GT2 810-2HC81 96/128 bit EPC, 64 byte -40°C to 85°C 127 x 38 x 6 IP67 RF625T 6GT2 810-2EE00 (ETSI) 6GT2 810-2EE01 (FCC) 96/128 bit EPC, 64 byte -40°C to 125°C Ø 30 x 8 IP68/ IPx9K RF645T 6GT2 810-2HC05 448 bit EPC, 256 byte -40°C to 85°C 52 x 36 x 12,5 IP68 SIMATIC Ident Configuration Guide RF680T 6GT2 810-2HG80 96/240 bit EPC, 64 byte -40°C to 220°C 130 x 32 x 15 IP68/ IPx9K RF615R*** (IP67) (internal antenna used) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) RF610R*** (IP67) (internal antenna used) 6GT2811-6BC10-0AA0 (ETSI) 6GT2811-6BC10-1AA0 (FCC) 6GT2811-6BC10-2AA0 (CMIIT) RF615R*** (IP67) (external antenna used) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) RF682T 6GT2810-3HG80 256 bit EPC, 384 byte -40°C to 220°C 130 x 32 x 15 IP68/ IPx9K 865-868 MHz (ETSI) 902-928 MHz (FCC) Passive Tags (with Gen2 protocol) RF600 Family Matrix Industrial Tags 133 x 133 x 45 RF615A*** RF622A*** 75 x 75 x 20 313 x 313 x 80 RF660A** 185 x 185 x 45 RF642A** RF650A** RF680A** 198 x 198 x 60 198 x 198 x 60 52 x 52 x 16 Antennas: 6GT2 812-0EA00 6GT2 812-0EA01 6GT2 812-2EA00 6GT2 812-2EA01 6GT2 812-1GA08 6GT2 812-0GB08 6GT2 812-0AA00 6GT2 812-0AA01 6GT2 812-2GB08 RF615A, linear, RF615A, linear, RF622A, linear, RF622A, linear, RF642A, linear, RF650A, circular, RF660A, circular, RF660A, circular, RF680A, switchable (ETSI) (FCC, CMIIT) (ETSI) (FCC, CMIIT) (all readers) (all readers) (ETSI) (FCC, CMIIT) , (all readers) Edition: July 2022 Integrated 6.0 (236) 5.0 (197) 4.0 (157) 3.0 (118) 3.5 (138) 5.0 (197) 1.8 / *1.2 (71 / *47) 1.2 / *0.8 (47 / *31) 0.4 (16) 0.7 / *0.5 (28 / *20) 0.8 / *0.6 (31 / *24) 1.4 / *1.0 (55 / *39) 1.8 / *1.2 (71 / *47) 1.2 / *0.8 (47 / *31) 0.4 (16) 0.8 / *0.5 (31 / *20) 0.9 / *0.7 (35 / *28) 1.4 / *1.0 (55 / *39) 5.0 (197) 5.0 / *4.5 (197 / *177) 5.0 / *4.5 (197 / *177) 3.0 (118) 3.5 (138) 5.0 (197) 4.0 / *3.0 (157 / *118) 3.0 / *2.0 (118 / *79) 2.0 / *1.2 (79 / *47) 1.8 / *1.4 (71 / *55) 2.5 / *1.8 (98 / *71) 3.5 / *2.5 (138 / *98) 5.0 (197) 4.0 (157) 4.0 / *3.5 (157 / *138) 2.5 (98) 3.0 (118) 4.0 (157) 4.5 / *3.0 (177 / *118) 3.5 / *2.0 (138 / *79) 2.0 / *1.2 (79 / *47) 1.8 / *1.4 (71 / *55) 2.5 / *1.8 (98 / *71) 3.5 / *2.5 (138 / *98) Accessories ** 3-way mounting kit (6GT2 890-2AB10) *** mounting plate (6GT2890-2AC00) Maximum operating distance (m) and maximum operating distance (inch) pay attention to the system manual for range overshoot 40SIMATIC Ident Configuration Guide * Use this value in combination with RF650R 260 x 193 x 52 RF615A*** Antennas RF685R** (IP65) (internal antenna used) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) RF650R** (IP30) 6GT2811-6AB20-0AA0 (ETSI) 6GT2811-6AB20-1AA0 (FCC) 6GT2811-6AB20-2AA0 (CMIIT) 6GT2811-6AB20-4AA0 (ARIB) RF680R** (IP65) 6GT2811-6AA10-0AA0 (ETSI) 6GT2811-6AA10-1AA0 (FCC) 6GT2811-6AA10-2AA0 (CMIIT) 6GT2811-6AA10-4AA0 (ARIB) RF685R** (IP65) (external antenna used) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) Operational Temperature Range Dimensions ( L x W x D) mm Ingress Protection (IP) Rating 865-868 MHz (ETSI) 902-928 MHz (FCC) Passive Tags (with Gen2 protocol) RF600 Family Matrix Labels RF622A*** 75 x 75 x 20 313 x 313 x 80 RF660A** 185 x 185 x 45 RF642A** RF650A** RF680A** 198 x 198 x 60 198 x 198 x 60 52 x 52 x 16 Antennas: 6GT2 812-0EA00 6GT2 812-0EA01 6GT2 812-2EA00 6GT2 812-2EA01 6GT2 812-1GA08 6GT2 812-0GB08 6GT2 812-0AA00 6GT2 812-0AA01 6GT2 812-2GB08 RF615A, linear, RF615A, linear, RF622A, linear, RF622A, linear, RF642A, linear, RF650A, circular, RF660A, circular, RF660A, circular, RF680A, switchable (ETSI) (FCC, CMIIT, ARIB) (ETSI) (FCC, CMIIT, ARIB) (all readers) (all readers) (ETSI) (FCC, CMIIT, ARIB) (all readers) RF630L 6GT2 810-2AB02-0AX0 128 bits EPC, 64 byte -40°C to 80°C 97 x 27 IP65 -40°C to 80°C 54 x 34 IP65 RF630L 6GT2 810-2AB03 96/240 bits EPC, 64 byte -20°C to 160°C 74 x 27 IP60 RF630L 6GT2 810-2AB04 256 bits EPC, 64 byte -40°C to 85°C 73 x 12.5 IP67 RF630L 6GT2 810-2AC84 448 bits EPC, 256 byte RF630L 6GT2 810-2AE82-0AX0 /-0AX1 /-0AX2 /-1AX0 /-2AX0 /-2AX1 128 bits EPC -25°C to 160°C various sizes* IP67 RF630L 6GT2 810-2AE83-1AX0 128 bits EPC -25°C to 130°C 45 x 20 IP67 washable Edition: July 2022 Integrated 5.0 (197) 5.0 (197) 6.0 (236) 2.0 (79) 6.0 (236) 1.2 / *0.7 (47 / *28) 1.4 / *1.0 (55 / *39) 1.2 / *0.8 (47 / *31) 0.5 / *0.4 (20 / *16) 1.6 / *1.2 (63 / *47) 1.2 / *0.8 (47 / *31) 1.4 / *1.0 (55 / *39) 1.4 / *0.9 (47 / *35) 0.5 / *0.4 (20 / *16) 1.8 / *1.2 (71 / *47) 5.0 (197) 5.0 (197) 5.0 (197) 2.0 (79) 6.0 (236) 3.5 / *2.0 (138 / *79) 3.5 / *2.5 (138 / *98) 5.0 / *4.0 (197 / *157) 1.6 / *1.2 (63 / *47) 4.0 / *3.0 (157 / *118) 4.0 (157) 4.0 (157) 5.0 (197) 1.6 (63) 5.0 (197) 4.0 / *2.5 (157 / *98) 3.5 / *2.5 (138 / *98) 6.0 / *4.5 (236 / *177) 1.6 / *1.2 (63 / *47) 5.0 / *3.0 (197 / *118) Accessories ** 3-way mounting kit (6GT2 890-2AB10) *** mounting plate (6GT2890-2AC00) Maximum operating distance (m) and maximum operating distance (inch) pay attention to the system manual for range overshoot 41SIMATIC Ident Configuration Guide * Use this value in combination with RF650R RF642L 6GT2810-3AC00 (ETSI) 6GT2810-3AC10 (FCC) 448 bit EPC, 256 byte -25°C to 85°C 50 x 22.5 x 1.6 IP68 260 x 193 x 52 RF615A*** 52 x 52 x 16 Antennas Operational Temperature Range Dimensions ( L x W x D) mm Ingress Protection (IP) Rating 865-868 MHz (ETSI) 902-928 MHz (FCC) Passive Tags (with Gen2 protocol) RF600 Family Matrix Labels -40°C to 120°C 75 x 20 IP67 RF630L 6GT2810-2AE81-0AX3 448 bit EPC, 256 Byte -40°C to 230°C 156 x 40 IP67 RF682L 6GT2810-2AG84-0AX0 448 bits EPC, 256 Byte RF685R** (IP65) (internal antenna used) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) RF650R** (IP30) 6GT2811-6AB20-0AA0 (ETSI) 6GT2811-6AB20-1AA0 (FCC) 6GT2811-6AB20-2AA0 (CMIIT) 6GT2811-6AB20-4AA0 (ARIB) RF680R** (IP65) 6GT2811-6AA10-0AA0 (ETSI) 6GT2811-6AA10-1AA0 (FCC) 6GT2811-6AA10-2AA0 (CMIIT) 6GT2811-6AA10-4AA0 (ARIB) RF685R** (IP65) (external antenna used) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) 313 x 313 x 80 RF660A** 185 x 185 x 45 RF642A** RF650A** RF680A** 198 x 198 x 60 198 x 198 x 60 RF622A*** 75 x 75 x 20 Antennas: 6GT2 812-0EA00 6GT2 812-0EA01 6GT2 812-2EA00 6GT2 812-2EA01 6GT2 812-1GA08 6GT2 812-0GB08 6GT2 812-0AA00 6GT2 812-0AA01 6GT2 812-2GB08 RF615A, linear, RF615A, linear, RF622A, linear, RF622A, linear, RF642A, linear, RF650A, circular, RF660A, circular, RF660A, circular, RF680A, switchable (ETSI) (FCC, CMIIT, ARIB) (ETSI) (FCC, CMIIT, ARIB) (all readers) (all readers) (ETSI) (FCC, CMIIT, ARIB) (all readers) -25°C to 130°C 105 x 25 IP67 RF630L 6GT2810-2AE83-0AX1 448 bit EPC, 256 Byte RF635L 6GT2810-3AC80-1AX0 256 bit EPC, 60 byte -25°C to 80°C 207,4 x 74 IP20 Edition: July 2022 Integrated 5.0 (197) 7.0 (276) 2.0 (79) 2.0 (79) 3.5 (138) 6.0 (236) 5.0 (197) 4.0 (157) 1.2 / *0.9 (47 / *35) 2.5 / *1.8 (98 / *71) 0.5 / *0.3 (20 / *12) 0.5 / *0.3 (20 / *12) 0.8 / *0.6 (31 / *24) 1.8 / *1.2 (71 / *47) 1.4 / *1.0 (55 / *39) 1.0 / *0.7 (39 / *28) 1.4 / *0.9 (55 / *35) 2.5 / *1.8 (98 / *71) 0.5 / *0.4 (20 / *16) 0.5 / *0.4 (20 / *16) 1.0 / *0.7 (39 / *28) 2.0 / *1.4 (79 / *55) 1.6 / *1.2 (63 / *47) 1.2 / *0.8 (47 / *31) 4.5 (177) 7.0 (275) 1.8 (71) 2.0 (79) 4.0 / *2.5 (157 / *98) 6.0 (236) 5.0 (197) 4.5 (177) 3.0 / *2.0 (118 / *79) 5.0 / *4.0 (197 / *157) 1.4 / *1.0 (55 / *39) 1.2 / *0.9 (47 / *35) 2.5 / *2.0 (98 / *79) 5.0 / *3.5 (197 / *138) 4.0 / *3.0 (157 / *118) 2.5 / *2.0 (98 / *79) 3.5 (138) 6.0 (236) 1.4 (55) 1.8 (71) 3.0 / *2.0 (118 / *79) 5.0 (197) 4.5 (177) 4.0 (157) 3.0 / *2.0 (118 / *79) 6.0 / *4.0 (236 / *157) 1.2 / *0.8 (47 / *31) 1.2 / *0.9 (47 / *35) 3.0 /*2.0 (118 / *79) 4.5 / *3.0 (177 / *118) 4.5 / *3.0 (177 /*118) 3.0 / *2.0 (118 / *79) Accessories ** 3-way mounting kit (6GT2 890-2AB10) *** mounting plate (6GT2890-2AC00) 20 mm Spacer (6GT2 190-0AA00) Fixing pocket (6GT2 190-0AB00) Spacer (6GT2 898-2AA00) Mounting cover 6GT2898-5AA00 Retaining bracket 6GT2898-5AB00 Retaining bracket 6GT2890-2AA00 Retaining bracket 6GT2890-2AA00 Maximum operating distance (m) and maximum operating distance (inch) pay attention to the system manual for range overshoot 42 260 x 193 x 52 SIMATIC Ident Configuration Guide * Use this value in combination with RF650R Antennas RF630T 6GT2 810-2EC00 (ETSI) 6GT2 810-2EC10 (FCC) 96/240 bit EPC, 64 byte -40°C to 125°C Ø 21x 20 IP68/ IPx9K RF640T 6GT2 810-2DC00 (ETSI) 6GT2 810-2DC10 (FCC) 96/240 bit EPC, 64 byte -40°C to 125°C Ø 50 x 8 IP68/ IPx9K RF610T 6GT2 810-2BB80 96/240 bit EPC, 64 byte -40°C to 85°C 86 x 54 x 0.4 IP67 RF620T 6GT2 810-2HC81 96/128 bit EPC, 64 byte -40°C to 85°C 127 x 38 x 6 IP67 RF625T 6GT2 810-2EE00 (ETSI) 6GT2 810-2EE01 (FCC) 96/128 bit EPC, 64 byte -40°C to 125°C Ø 30 x 8 IP68/ IPx9K RF645T 6GT2 810-2HC05 448 bit EPC, 256 byte -40°C to 85°C 52 x 36 x 12,5 IP68 RF680T 6GT2 810-2HG80 96/240 bit EPC, 64 byte -40°C to 220°C 130 x 32 x 15 IP68/ IPx9K RF682T 6GT2810-3HG80 224 bit EPC, 384 byte -40°C to 220°C 130 x 32 x 15 IP68/ IPx9K Operational Temperature Range Dimensions ( L x W x D) mm Ingress Protection (IP) Rating 865-868 MHz (ETSI) 902-928 MHz (FCC) Passive Tags (with Gen2 protocol) RF600 Family Matrix Industrial Tags RF685R** (IP65) (internal antenna used) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) RF650R** (IP30) 6GT2811-6AB20-0AA0 (ETSI) 6GT2811-6AB20-1AA0 (FCC) 6GT2811-6AB20-2AA0 (CMIIT) 6GT2811-6AB20-4AA0 (ARIB) RF680R** (IP65) 6GT2811-6AA10-0AA0 (ETSI) 6GT2811-6AA10-1AA0 (FCC) 6GT2811-6AA10-2AA0 (CMIIT) 6GT2811-6AA10-4AA0 (ARIB) RF685R** (IP65) (external antenna used) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) RF622A*** 75 x 75 x 20 313 x 313 x 80 RF660A** 185 x 185 x 45 RF642A** RF650A** RF680A** 198 x 198 x 60 198 x 198 x 60 RF615A*** 52 x 52 x 16 Antennas: 6GT2 812-0EA00 6GT2 812-0EA01 6GT2 812-2EA00 6GT2 812-2EA01 6GT2 812-1GA08 6GT2 812-0GB08 6GT2 812-0AA00 6GT2 812-0AA01 6GT2 812-2GB08 RF615A, linear, RF615A, linear, RF622A, linear, RF622A, linear, RF642A, linear, RF650A, circular, RF660A, circular, RF660A, circular, RF680A, switchable (ETSI) (FCC, CMIIT, ARIB) (ETSI) (FCC, CMIIT, ARIB) (all readers) (all readers) (ETSI) (FCC, CMIIT, ARIB) (all readers) Edition: July 2022 43 Reader RF600 System Interfaces SIMATIC Ident Configuration Guide PROFINET & OPC UA & Ethernet/IP & TCP/IP General host application as a, XML client b, Off-the-shelf third-party RFID Middleware c, OPC UA for AutoID Client Controller Application written in any controller language using Ident library with Ident profile + +Ethernet /PN Cable M12 length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required) Direct connection Ethernet /PN Cable M12 length from 2 to 15 m available e.g. 2 m = 6XV1871-5TH20 Network Connection via Switch IE switch SCALANCE X (6GK5 ) + length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 ++ + Controller Library and Demo-Software on DVD PROFIBUS Powered through connection cable RF610R (only internal antenna) 6GT2811-6BC10-0AA0 (ETSI) 6GT2811-6BC10-1AA0 (FCC) 6GT2811-6BC10-2AA0 (CMIIT) RF615R (internal antenna and optional 1 ext. antenna) 6GT2811-6CC10-0AA0 (ETSI) 6GT2811-6CC10-1AA0 (FCC) 6GT2811-6CC10-2AA0 (CMIIT) External antennas: RF615A 6GT2 812-0EA00; ETSI 6GT2 812-0EA01; FCC, etc. RF622A 6GT2812-2EA00, ETSI 6GT2812-2EA01, FCC, etc. RF642A 6GT2 812-1GA08 RF650A 6GT2 812-0GB08 RF660A 6GT2 812-0AA00, ETSI 6GT2 812-0AA01, FCC, etc. RF680A 6GT2 812-2GB08 Antenna Cable 1m = 6GT2815-0BH10 3m = 6GT2 815-0BH30 5m, flex = 6GT2 815-2BH50 10m,2dB = 6GT2 815-1BN10 10m,4dB = 6GT2 815-0BN10 15m,flex = 6GT2 815-2BN15 20m = 6GT2 815-0BN20 40m = 6GT2 815-0BN40 Power Splitter 6GT2 890-0BC00 DI/DO interface Use a M12 A-coded connector 3RK1902-4BA00-5AA0 Cover caps 6GT2898-4AA10 Connection with external power supply Power supply EU connector 6GT2 898-0AC00 US connector 6GT2 898-0AC20 UK connector 6GT2 898-0AC10 cable 24 V for power supply 5 m = 6GT2 891-0PH50 cable w/ open ends 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 Labels RF620T 6GT2 810-2HC81 RF640T Gen2 6GT2 810-2DC00 (ETSI) 6GT2 810-2DC10 (FCC) RF610T 6GT2 810-2BB80 Tags RF630T 6GT2 810-2EC00 (ETSI) 6GT2 810-2EC10 (FCC) RF680T 6GT2 810-2HG80 RF682L 6GT2810-2AG84-0AX0 RF625T 6GT2 810-2EE00 (ETSI) 6GT2 810-2EE01 (FCC) RF642L 6GT2 810-3AC00 (ETSI) 6GT2 810-3AC10 (FCC) RF690L 6GT2 810-2AG00 (ETSI) 6GT2 810-2AG10 (FCC) RF645T 6GT2 810-2HC05 RF682T 6GT2 810-3HG80 RF630L 6GT2 810-2AB02-0AX0 6GT2 810-2AE82-xxxx 6GT2810-2AB04-0AX1 6GT2810-2AB04 6GT2810-2AC82 6GT2810-2AC84 6GT2810-2AE83-0AX1 6GT2 810-2AE81-0AX3 RF635L 6GT2810-3AC80-1AX0 + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) A maximum of 2 readers may be connected +RF166C to RF6x0R 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 Opt.: 3-way mounting kit 6GT2890-2AB10 Opt.: Mounting plate 6GT2890-2AC00 Edition: July 2022 44 Ethernet TCP/IP Reader with external power supply Host application as a, XML client b, Off-the-shelf third-party RFID Middleware c, OPC UA for AutoID Client + +RF650R Ethernet Connection Cable 0.5 to 50 m available; e.g. 2 m = 6XV1870-3QH20 (no switch required) Demo-Software on DVD RF600 System Interfaces Direct connection RF650R Ethernet Connection Cable 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 Network Connection via Switch IE Switch SCALANCE X (6GK5 ) ++++ length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 SIMATIC Ident Configuration Guide RF650R (1 to 4 ext. antennas) 6GT2811-6AB20-0AA0 (ETSI) 6GT2811-6AB20-1AA0 (FCC) 6GT2811-6AB20-2AA0 (CMIIT) 6GT2811-6AB20-4AA0 (ARIB) RF680R (1 to 4 ext. antennas) 6GT2811-6AA10-0AA0 (ETSI) 6GT2811-6AA10-1AA0 (FCC) 6GT2811-6AA10-2AA0 (CMIIT) 6GT2811-6AA10-4AA0 (ARIB) RF685R (internal antenna and optional 1 ext. antenna) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) PROFINET & OPC UA & Ethernet/IP & TCP/IP General host application as a, XML client b, Off-the-shelf third-party RFID Middleware c, OPC UA for AutoID Client Controller Application written in any controller language using Ident library with Ident profile + +Ethernet /PN Cable M12 length from 2 to 15 m available; e.g. 2 m = 6XV1871-5TH20 (no switch required) Direct connection Ethernet /PN Cable M12 length from 2 to 15 m available e.g. 2 m = 6XV1871-5TH20 Network Connection via Switch IE switch SCALANCE X (6GK5 ) + length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 ++ + Controller Library and Demo-Software on DVD Cover caps (6GT2898-4AA10) RF615A 6GT2 812-0EA00; ETSI 6GT2 812-0EA01; FCC, etc. RF622A 6GT2812-2EA00, ETSI 6GT2812-2EA01, FCC, etc. RF642A 6GT2 812-1GA08 RF650A 6GT2 812-0GB08 RF660A 6GT2 812-0AA00, ETSI 6GT2 812-0AA01, FCC, etc. RF680A 6GT2 812-2GB08 Antenna Mounting kit 6GT2 890-2AB10 Antenna Cable 1m = 6GT2815-0BH10 3m = 6GT2 815-0BH30 5m, flex = 6GT2 815-2BH50 10m,2dB = 6GT2 815-1BN10 10m,4dB = 6GT2 815-0BN10 15m,flex = 6GT2 815-2BN15 20m = 6GT2 815-0BN20 40m = 6GT2 815-0BN40 Power Splitter 6GT2 890-0BC00 (do not use with RF680A) Power supply EU connector 6GT2 898-0AC00 US connector 6GT2 898-0AC20 UK connector 6GT2 898-0AC10 cable 24 V for power supply 5 m = 6GT2 891-0PH50 cable w/ open ends 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50 optional DI/DO cable 5m 6GT2891-0CH50 3-way mounting kit 6GT2890-2AB10 Mounting plate 6GT2890-2AC00 Rail mounting set 6GT2890-0AB00 Labels RF620T 6GT2 810-2HC81 RF640T Gen2 6GT2 810-2DC00 (ETSI) 6GT2 810-2DC10 (FCC) RF610T 6GT2 810-2BB80 Tags RF630T 6GT2 810-2EC00 (ETSI) 6GT2 810-2EC10 (FCC) RF680T 6GT2 810-2HG80 RF682L 6GT2810-2AG84-0AX0 RF625T 6GT2 810-2EE00 (ETSI) 6GT2 810-2EE01 (FCC) RF642L 6GT2 810-3AC00 (ETSI) 6GT2 810-3AC10 (FCC) RF690L 6GT2 810-2AG00 (ETSI) 6GT2 810-2AG10 (FCC) RF645T 6GT2 810-2HC05 RF682T 6GT2 810-3HG80 RF630L 6GT2 810-2AB02-0AX0 6GT2 810-2AE82-xxxx 6GT2810-2AB04-0AX1 6GT2810-2AB04 6GT2810-2AC82 6GT2810-2AC84 6GT2810-2AE83-0AX1 6GT2 810-2AE81-0AX3 RF635L 6GT2810-3AC80-1AX0 Edition: July 2022 45 Reader powered through connection cable RF600 System Interfaces SIMATIC Ident Configuration Guide Cover caps (6GT2898-4AA10) PROFIBUS optional DI/DO cable 5m 6GT2891-0CH50 3-way mounting kit 6GT2890-2AB10 Mounting plate 6GT2890-2AC00 Rail mounting set 6GT2890-0AB00 RF680R (1 to 4 ext. antennas) 6GT2811-6AA10-0AA0 (ETSI) 6GT2811-6AA10-1AA0 (FCC) 6GT2811-6AA10-2AA0 (CMIIT) 6GT2811-6AA10-4AA0 (ARIB) RF685R (internal antenna and optional 1 ext. antenna) 6GT2811-6CA10-0AA0 (ETSI) 6GT2811-6CA10-1AA0 (FCC) 6GT2811-6CA10-2AA 0 (CMIIT) 6GT2811-6CA10-4AA0 (ARIB) RF615A 6GT2 812-0EA00; ETSI 6GT2 812-0EA01; FCC, etc. RF622A 6GT2812-2EA00, ETSI 6GT2812-2EA01, FCC, etc. RF642A 6GT2 812-1GA08 RF650A 6GT2 812-0GB08 RF660A 6GT2 812-0AA00, ETSI 6GT2 812-0AA01, FCC, etc. RF680A 6GT2 812-2GB08 Antenna Cable 1m = 6GT2815-0BH10 3m = 6GT2 815-0BH30 5m, flex = 6GT2 815-2BH50 10m,2dB = 6GT2 815-1BN10 10m,4dB = 6GT2 815-0BN10 15m,flex = 6GT2 815-2BN15 20m = 6GT2 815-0BN20 40m = 6GT2 815-0BN40 Power Splitter 6GT2 890-0BC00 (do not use with RF680A) + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) A maximum of 2 readers may be connected +RF166C to RF6x0R 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50* Reader connector 90° angled 2 m = 6GT2 891-4JH20 5 m = 6GT2 891-4JH50 10 m = 6GT2 891-4JN10 Labels RF620T 6GT2 810-2HC81 RF640T Gen2 6GT2 810-2DC00 (ETSI) 6GT2 810-2DC10 (FCC) RF610T 6GT2 810-2BB80 Tags RF630T 6GT2 810-2EC00 (ETSI) 6GT2 810-2EC10 (FCC) RF680T 6GT2 810-2HG80 RF682L 6GT2810-2AG84-0AX0 RF625T 6GT2 810-2EE00 (ETSI) 6GT2 810-2EE01 (FCC) RF642L 6GT2 810-3AC00 (ETSI) 6GT2 810-3AC10 (FCC) RF690L 6GT2 810-2AG00 (ETSI) 6GT2 810-2AG10 (FCC) RF645T 6GT2 810-2HC05 RF682T 6GT2 810-3HG80 RF630L 6GT2 810-2AB02-0AX0 6GT2 810-2AE82-xxxx 6GT2810-2AB04-0AX1 6GT2810-2AB04 6GT2810-2AC82 6GT2810-2AC84 6GT2810-2AE83-0AX1 6GT2 810-2AE81-0AX3 RF635L 6GT2810-3AC80-1AX0 Edition: July 2022 RF1040R (USB, RS232) 6GT2831-6CA50 30 (1.18) 30 (1.18) 30 (1.18) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) RF1060R (USB) 6GT2831-6AA50 30 (1.18) 30** (1.18) 30 (1.18) 10 (0.39) 10 (0.39) 10 (0.39) 10 (0.39) RF1070R (USB, RS232) 6GT2831-6BA50 6GT2831-6BA50-0AX0 (OEM*) 30 (1.18) 30 (1.18) 10 (0.39) 10 (0.39) 13.56 MHz Passive Tags 46 RF1000 Family Matrix D200 6GT2 600-1AD00 -0AX0 256 byte EEPROM -20°C to 60°C 85.6 x 54 x 0.8 IP67 D400 6GT2 600-4AD00 2 kbyte FRAM -20°C to 60°C 85.6 x 54 x 0.8 IP67 Maximum Distance for Stationary Tag (mm) Maximum Distance for Stationary Tag (inch) SIMATIC Ident Configuration Guide Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating D100 6GT2 600-0AD10 112 byte EEPROM -25°C to 80°C 85,6 x 54 x 0.9 IP68 * ATEX not valid for OEM type) ** only for read-only access D324 6GT2 600-3AC00 992 byte EEPROM -40°C to 140°C Ø 27 x 4 IP67 D424 6GT2 600-4AC00 2 kbyte FRAM -40°C to 100°C Ø 27 x 4 IP67/ IPx9K D124 6GT2 600-0AC10 112 byte EEPROM -40°C to 180°C Ø 27 x 4 IP68/ IPx9K D524 6GT2 600-5AC00 8 kByte FRAM -40°C to 100°C Ø 27 x 4 IP67 / IPx9k Edition: July 2022 RF1040R (USB, RS232) 6GT2831-6CA50 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) RF1060R (USB) 6GT2831-6AA50 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) RF1070R (USB, RS232) 6GT2831-6BA50 6GT2831-6BA50-0AX0 (OEM*) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 30 (1.18) 13.56 MHz and 125 kHz passive tags 47 RF1000 Family Matrix Maximum Distance for Stationary Tag (mm) Maximum Distance for Stationary Tag (inch) SIMATIC Ident Configuration Guide Operational temperature range Dimensions (L x W x D) mm Ingress Protection (IP) rating E611 6GT2 300-0BB00 752 byte EEPROM -40°C to 85°C 86 x 54 x 2.5 IP67 E600 6GT2 300-0AA00 752 byte EEPROM -25°C to 60°C 86 x 54 x 0.76 IP68 Company badges and transponders acc. ISO 14443 A/B ISO 14443 Company badges and Transponders acc. Legic Prime and Legic Advant Legic Company badges and Transponders acc. Hitag 1/2/S EM41xx, EKS and more 125 kHz (LF) * ATEX not valid for OEM type) D426 6GT2 600-4AH00 2 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D526 6GT2 600-5AH00 8 kbyte FRAM -40°C to 100°C Ø 50 x 3.6 IP68 D126 6GT2 600-0AE00 112 byte EEPROM -40°C to 100°C Ø 50 x 3.6 IP68 Edition: July 2022 RF1000 System Interfaces 48 RF1060R (6GT2 831-6AA50) USB DLL and simple Demo for PC: https://support.industry.siemens.com/cs/ww/en/view/109741590 Local user administration for Comfort Panels and IPC: https://support.industry.siemens.com/cs/de/en/view/109754400 (included in SIMATIC HMI Option+) Central user management PM Logon https://www.siemens.com/pm-logon https://support.industry.siemens.com/cs/ww/en/view/109779685 SIMATIC Logon / Logon Remote Access https://support.industry.siemens.com/cs/ww/en/view/109749167 (USB cable 1.8 m included) 1 Reader per USB port type A + Reader Powered through USB cable SIMATIC Ident Configuration Guide 0.5 m = 6GT2 891-0UE50 Optional: short USB cable RF1070R (6GT2 831-6BA50) (6GT2 831-6BA50-0AX0, OEM**** ) RF1040R (6GT2 831-6CA50) **** ATEX not valid for OEM type) ***** planned for November 2021 Tags **) Company badges and transponders acc. ISO 14443 A/B Incl. MDS E600/E611 D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00)* D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00)* D526 (6GT2 600-5AH00)* Company badges and Transponders acc. Legic Prime and Legic Advant Tag restrictions: * not for RF1070R ** only with RF1070R *** only with RF1040R Company badges and Transponders acc. Hitag 1/2/S, EM41xx, EKS and more ***) Transponders acc. ISO 15693 D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00)* D524 (6GT2 600-5AC00)* Optional: Card holder 6GT2 890-0CA00 ConfigCard (for customer-specific reader configuration) 6GT2300-0CC00-0AX0 Extension unit IP65 for operator controls 12 6AV7674-1LA31-0AA0 15 6AV7674-1LA41-0AA0 19 6AV7674-1LA51-0AA0 22 6AV7674-1LA61-0AA0 Housing for desktop and wall mounting 6GT2890-0CB00 ***** Cleanroom cap (no usage with card holder) for wall mount 6GT2890-0CC00 ***** requires 6GT2890-0CB00 for control cabinet mount 6GT2890-0CD00 ***** Edition: July 2022 RF1000 System Interfaces 49 Reader Powered through connection cable SIMATIC Ident Configuration Guide RF1070R (6GT2 831-6BA50) (6GT2 831-6BA50-0AX0, OEM**** ) RF1040R (6GT2 831-6CA50) PROFIBUS + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) PROFINET & Ethernet/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + Or one Standard sensor Or one Actor ++ Connection cable: 2m = 6GT2891-4UH20 (do not use an additional extension cable) A maximum of 1 reader at RF185C, 2 readers at RF186C/CI, RF188C/CI of RF1000 may be connected (RS232) + Connection cable: 2m = 6GT2891-4UH20 (do not use an additional extension cable) A maximum of 2 readers may be connected (RS232) Types of IO-Link IO module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) Tags **) Company badges and transponders acc. ISO 14443 A/B Incl. MDS E600/E611 D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00)* D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00)* D526 (6GT2 600-5AH00)* Company badges and Transponders acc. Legic Prime and Legic Advant Tag restrictions: * not for RF1070R ** only with RF1070R *** only with RF1040R Company badges and Transponders acc. Hitag 1/2/S, EM41xx, EKS and more ***) Transponders acc. ISO 15693 D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00)* D524 (6GT2 600-5AC00)* Optional: Card holder 6GT2 890-0CA00 ConfigCard (for customer-specific reader configuration) 6GT2300-0CC00-0AX0 Extension unit IP65 for operator controls 12 6AV7674-1LA31-0AA0 15 6AV7674-1LA41-0AA0 19 6AV7674-1LA51-0AA0 22 6AV7674-1LA61-0AA0 Housing for desktop and wall mounting 6GT2890-0CB00 ***** Cleanroom cap (no usage with card holder) for wall mount 6GT2890-0CC00 ***** requires 6GT2890-0CB00 for control cabinet mount 6GT2890-0CD00 ***** **** ATEX not valid for OEM type) ***** planned for November 2021 Edition: July 2022 RF1000 System Interfaces 50 Reader Powered through connection cable SIMATIC Ident Configuration Guide RF1070R (6GT2 831-6BA50) (6GT2 831-6BA50-0AX0, OEM**** ) + LOGO POWER 220V/5V 6EP3310-6SB00-0AY0 The max. current of 3 A may supply up to 10 Reader Serial interface RS232 6ES7137-6AA00-0BA0 + + RF170C Communication module (6GT2002-0HD01) Connection block (6GT2002-1HD01) Connection cable: 2m = 6GT2891-4UH20 (do not use an additional extension cable) Connection cable: 3m = 6GT2891-2UH30 (do not use an additional extension cable) ET 200SP via serial modul (example; also useful for the connection to other serial modules) ET 200pro via PROFIBUS or PROFINET or S7 PLC + ET 200pro PROFIBUS DP-V1 Interface Modul ET 200pro PROFINET Interface Modul Up to 9 x RF170C modules per ET 200pro rack ET 200pro PROFINET CPU module A maximum of 2 readers may be connected (RS232) A maximum of 1 reader per serial module may be connected (RS232) Use standard function block Ident Profile Use : P2P_Send and P2P_Receive for programming + RF1040R (6GT2 831-6CA50) Application example available: https://support.industry.siemens.com/cs/ww/de/view/109770535 SIMATIC PLC S7-1200 A maximum of 1 readers may be connected +RF120C to RF10x0R 2 m = 6GT2891-6UH20+ RF120C 6GT2 002-0LA00 Up to 3 x RF120C modules per S7-1200 rack Tags **) Company badges and transponders acc. ISO 14443 A/B Incl. MDS E600/E611 D100 (6GT2 600-0AD10) D200 (6GT2 600-1AD00 -0AX0) D400 (6GT2 600-4AD00)* D126 (6GT2 600-0AE00) D426 (6GT2 600-4AH00)* D526 (6GT2 600-5AH00)* Company badges and Transponders acc. Legic Prime and Legic Advant Tag restrictions: * not for RF1070R ** only with RF1070R *** only with RF1040R Company badges and Transponders acc. Hitag 1/2/S, EM41xx, EKS and more ***) Transponders acc. ISO 15693 D124 (6GT2 600-0AC10) D324 (6GT2 600-3AC00) D424 (6GT2 600-4AC00)* D524 (6GT2 600-5AC00)* Optional: Card holder 6GT2 890-0CA00 ConfigCard (for customer-specific reader configuration) 6GT2300-0CC00-0AX0 Extension unit IP65 for operator controls 12 6AV7674-1LA31-0AA0 15 6AV7674-1LA41-0AA0 19 6AV7674-1LA51-0AA0 22 6AV7674-1LA61-0AA0 Housing for desktop and wall mounting 6GT2890-0CB00 ***** Cleanroom cap (no usage with card holder) for wall mount 6GT2890-0CC00 ***** requires 6GT2890-0CB00 for control cabinet mount 6GT2890-0CD00 ***** **** ATEX not valid for OEM type) ***** planned for November 2021 Edition: July 2022 Handheld (w/o Reading Head) Additional Components Spare Parts Mobile Reader Basic Device for HF and UHF Reading head with user software and rechargeable battery (without charging / docking unit) Docking / Charging Unit 6GT2003-0FB00 Pistol Grip 6GT2093-0FG00 Spare Battery for RF160B 6GT2093-0FA00 SIMATIC RF160B 6GT2003-0FA00 SIMATIC RF Handhelds Mobile Reader Basic Device for HF and UHF Reading head with user Software and rechargeable battery (without charging / docking station) UHF Head ETSI (6GT2813-1FA00) HF Head with int Antenna (6GT2803-1FA00) UHF Head FCC (6GT2813-1FA10) HF Head for Antenna (6GT2803-1FA10) UHF Head CMIIT (6GT2813-1FA20) UHF HEAD HF HEAD SIMATIC Ident Configuration GuideEdition: July 2022 52 SIMATIC RF Handheld WITH EXT ANTENNA 52 HF Head for Antenna (6GT2803-1FA10) HF HEAD External Antenna Antenna without cable MLFB Suitable for Ant 3 6GT2 398-1CD30- 0AX0 D124, D160, D324, D422, D423, D424, D425, D428, D460, D522, D524, D525, D528, E624, RF320T, RF330T, RF340T, RF350T, RF360T Ant 3S 6GT2 398-1CD50- 0AX0 D117, D127, D421, D521 Ant 8 6GT2 398-1CF00 D117, D127, D421 Ant 12 ** 6GT2 398-1DC00 D117, D127, D160, D421, D428, D460, D521, D528, E623, RF330T Ant 18 ** 6GT2 398-1DA00 D117, D124, D127, D160, D324, D421, D422, D424, D425, D428, D460, D521, D522, D524, D525, D528, E623, E624 RF320T, RF330T, RF340T Ant 30 6GT2 398-1DD00 D124, D126, D160, D324, D422, D423, D424, D425, D426, D428, D460, D522, D524, D525, D526, D528, E624, RF320T, RF330T, RF340T, RF350T, RF360T Antenna cables MLFB Suitable for 0.1 m 0.6 m 3 m 6GT2 898-0EA00 6GT2 391-0AE60 6GT2 391-0AH30 For all antenna types above Only for antennas marked with ** For all antenna types above SIMATIC Ident Configuration GuideEdition: July 2022 Ethernet TCP/IP + + S7-300/1500 via Industrial Ethernet or PROFINET S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 + + S7-1200 via Industrial Ethernet or PROFINET + + S7-1200 CPU MV500 System Interfaces + CSM 377 (6GK7 377-1AA00-0AA0) ++ Direct connection (1 reader may be connected) A maximum of 3 readers may be connected Direct connection (1 reader may be connected) + + A maximum of 3 readers may be connected)++ CSM 1277 (6GK7 277-1AA10-0AA0) Direct connection MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) ++++ + Network Connection via Compact Switch Module Network Connection via Compact Switch Module 53 MV500 Ethernet Connection Cable length form 0.3 m to15 m available e.g. 2 m = 6XV1870-8GH20 or MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) SIMATIC Ident Configuration Guide Use library Ident Profile Use library Ident Profile Use native TCP/IP with text based commands Network Connection via Switch IP 20: IE switch SCALANCE X (6GK5 ) IP 65: IE switch SCALANCE XP208 (6GK5208-0HA00-2AS6) Reader With external power supply MV530 S; 800 x 600 pixel: (6GF3530-0CD10) H; 1280 x 1024 pixel: (6GF3530-0GE10) Options DO Wires included in power supply cable Open wires Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD ³) Custom assembly necessary; use the correct stripping tool or Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Pat-Genius 6GF3400-0SL03 Edition: July 2022 Ethernet TCP/IP + + S7-300/1500 via Industrial Ethernet or PROFINET S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 + + S7-1200 via Industrial Ethernet or PROFINET + + S7-1200 CPU + CSM 377 (6GK7 377-1AA00-0AA0) ++ Direct connection (1 reader may be connected) A maximum of 3 readers may be connected Direct connection (1 reader may be connected) + + A maximum of 3 readers may be connected)++ CSM 1277 (6GK7 277-1AA10-0AA0) Direct connection MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) ++++ + Network Connection via Compact Switch Module Network Connection via Compact Switch Module 54 MV500 Ethernet Connection Cable length form 0.3 m to15 m available e.g. 2 m = 6XV1870-8GH20 or MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) SIMATIC Ident Configuration Guide Use library Ident Profile Use library Ident Profile Use native TCP/IP with text based commands Network Connection via Switch IP 20: IE switch SCALANCE X (6GK5 ) IP 65: IE switch SCALANCE XP208 (6GK5208-0HA00-2AS6) Reader With external power supply MV540 S; 800 x 600 pixel: (6GF3540-0CD10) H; 1280 x 1024 pixel: (6GF3540-0GE10) MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Options DO Wires included in power supply cable Open wires Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed Lights external: ring Red: 6GF3400-0LT01-8DA1 Infrared: 6GF3400-0LT01-7BA1 adapter M12/M12: 6GF3500-8BD10 mounting plate: 6GF3440-8CD01 + Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) ³) Custom assembly necessary; use the correct stripping tool or Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) s) sh) 1) sh) ux) 1) 4) sh) ux) 1) 4) sh) ux) 1) 4) shux) shux) Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights external: panel 20x20 cm: 6GF3500-8DF30-1DA0 30x20 cm: 6GF3500-8DF30-2DA0 40x30 cm: 6GF3500-8DF30-3DA0 Mounting aid 6GF3500-8CD + MV500 System Interfaces Edition: July 2022 Ethernet TCP/IP or PROFINET (PoE): 100MB Network Connection via SCALANCE Switches PoE IE switch SCALANCE X108 PoE (6GK5108-0PA00-2AA3) ++++ length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 S7-1200 CPU PC IE switch SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) IE switch SCALANCE XR324-4M PoE (e.g. 6GK5324-4QG00-3AR2) SIMATIC Ident Configuration Guide Use native TCP/IP with text based commands Use library Ident Profile Use library Ident Profile IE switch SCALANCE XP208 PoE EEC (6GK5208-0UA00-5ES6) or or or or IE switch SCALANCE XP216 PoE EEC (6GK5216-0UA00-5ES6) 55 Options DO Additional cable for DO-supply is needed 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901- 1BB10-2AA0 ³) + MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) Reader With power supply over Ethernet (PoE) ³) Custom assembly necessary; use the correct stripping tool Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Software Pat-Genius 6GF3400-0SL03 MV530 S; 800 x 600 pixel: (6GF3530-0CD10) H; 1280 x 1024 pixel: (6GF3530-0GE10) Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 or MV500 System Interfaces Edition: July 2022 Ethernet TCP/IP or PROFINET (PoE): 100MB Network Connection via SCALANCE Switches PoE IE switch SCALANCE X108 PoE (6GK5108-0PA00-2AA3) ++++ length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 S7-1200 CPU PC IE switch SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) IE switch SCALANCE XR324-4M PoE (e.g. 6GK5324-4QG00-3AR2) SIMATIC Ident Configuration Guide Use native TCP/IP with text based commands Use library Ident Profile Use library Ident Profile IE switch SCALANCE XP208 PoE EEC (6GK5208-0UA00-5ES6) or or or or IE switch SCALANCE XP216 PoE EEC (6GK5216-0UA00-5ES6) 56 Options DO Additional cable for DO-supply is needed 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901- 1BB10-2AA0 ³) + MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) Reader With power supply over Ethernet (PoE) ³) Custom assembly necessary; use the correct stripping tool 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed MV540 S; 800 x 600 pixel: (6GF3540-0CD10) H; 1280 x 1024 pixel: (6GF3540-0GE10) MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 s) sh) 1) sh) ux) 1) 4) sh) ux) 1) 4) sh) ux) 1) 4) shux) shux) Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 MV500 System Interfaces Edition: July 2022 Two parallel Networks on one Device: 1000MB + 100MB Network Connection via SCALANCE Switches PoE IE switch SCALANCE X108 PoE (6GK5108-0PA00-2AA3) ++++ MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 PC IE switch SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) or IE switch SCALANCE XR324-4M PoE (e.g. 6GK5324-4QG00-3AR2) SIMATIC Ident Configuration Guide Use native TCP/IP with text based commands IE switch SCALANCE XP208 PoE EEC (6GK5208-0UA00-5ES6) or or IE switch SCALANCE XP216 PoE EEC (6GK5216-0UA00-5ES6) 57 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 Reader With power supply over Ethernet (PoE)1000MB / GigE Network, no PoE possible 100 MB / Profinet Network, Switch with PoE MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1878-5GH20IP 65: IE switch SCALANCE XP216 (e.g. 6GK5216-0HA00-2AS6) Direct connection MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) (no switch required) Network Connection via Switch IP 20: IE switch SCALANCE X GB (e.g. 6GK5208-0GA00-2AC2) S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 S7-1200 CPU Use library Ident Profile Use library Ident Profile PC Use native TCP/IP with text based commands ++ ++ length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 + + ++ or ³) Custom assembly necessary; use the correct stripping tool 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed Options DO Additional cable for DO-supply is needed 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) s) sh) 1) sh) ux) 1) 4) sh) ux) 1) 4) sh) ux) 1) 4) shux) shux) Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 MV500 System Interfaces Edition: July 2022 A maximum of 2 readers may be connected + ET 200pro via PROFIBUS or PROFINET or S7 PLC ++ RF170C Communication module (6GT2002-0HD01) Connection block (6GT2002-1HD01) ET 200pro PROFIBUS DP-V1 Interface module ET 200pro PROFINET Interface module Up to 9 x 170C modules per ET 200pro rack ET 200pro PROFINET CPU module SIMATIC PLC S7-1200 SIMATIC PLC S7-300 Rack or S7-400 via ET 200M (DP-V1/PN-IO) A maximum of 2 readers may be connected + ASM 475 + Front connector (6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) + + Accessories: Connecting element (6ES7 390-5AA00-0AA0) Terminal element (6ES7 390-5BA00-0AA0) A maximum of 1 reader may be connected +RF120C to MV500 adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50 10m = 6GT2 091-4LN10 + RF120C 6GT2 002-0LA00 58 + ASM 475 to MV500 adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50+ (+) PROFIBUS + A maximum of 2 readers may be connected+RF166C to MV500 (+) RF166C (DP-V1) Communication Module (6GT2 002-0EE20) adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 SIMATIC Ident Configuration Guide MV530 S; 800 x 600 pixel: (6GF3530-0CD10) H; 1280 x 1024 pixel: (6GF3530-0GE10) Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 or Reader With external power supply Options DO Wires included in power supply cable Open wires Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Pat-Genius 6GF3400-0SL03 MV500 System Interfaces Edition: July 2022 A maximum of 2 readers may be connected + ET 200pro via PROFIBUS or PROFINET or S7 PLC ++ RF170C Communication module (6GT2002-0HD01) Connection block (6GT2002-1HD01) ET 200pro PROFIBUS DP-V1 Interface module ET 200pro PROFINET Interface module Up to 9 x 170C modules per ET 200pro rack ET 200pro PROFINET CPU module SIMATIC PLC S7-1200 SIMATIC PLC S7-300 Rack or S7-400 via ET 200M (DP-V1/PN-IO) A maximum of 2 readers may be connected + ASM 475 + Front connector (6GT2 002-0GA10) + (6ES7 392-1AJ00-0AA0) + + Accessories: Connecting element (6ES7 390-5AA00-0AA0) Terminal element (6ES7 390-5BA00-0AA0) A maximum of 1 reader may be connected +RF120C to MV500 adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 2 m = 6GT2 091-4LH20 5 m = 6GT2 091-4LH50 10m = 6GT2 091-4LN10 + RF120C 6GT2 002-0LA00 Options 59 + ASM 475 to MV500 adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 2 m = 6GT2 891-4EH20 5 m = 6GT2 891-4EH50+ (+) Reader Powered through connection cable PROFIBUS + A maximum of 2 readers may be connected+RF166C to MV500 (+) RF166C (DP-V1) Communication Module (6GT2 002-0EE20) adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 SIMATIC Ident Configuration Guide 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed MV540 S; 800 x 600 pixel: (6GF3540-0CD10) H; 1280 x 1024 pixel: (6GF3540-0GE10) MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) s) sh) 1) sh) ux) 1) 4) sh) ux) 1) 4) sh) ux) 1) 4) shux) shux) Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 MV500 System Interfaces Edition: July 2022 MV530 System Interfaces SIMATIC Ident Configuration Guide 60 ++ PROFINET & Ethernet/IP & OPC UA & TCP/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + Or one Standard sensor Or one Actor (+) A maximum of 1 reader at RF185C, 2 readers at RF186C/CI, 4 readers at RF188C/CI of MV500 may be connected adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 Types of IO-Link I/O module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) MV530 S; 800 x 600 pixel: (6GF3530-0CD10) H; 1280 x 1024 pixel: (6GF3530-0GE10) Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 or Reader With external power supply Options DO Wires included in power supply cable Open wires Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Pat-Genius 6GF3400-0SL03 Edition: July 2022 SIMATIC Ident Configuration Guide Options 61 Reader Powered through connection cable ++ PROFINET & Ethernet/IP & OPC UA & TCP/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + Or one Standard sensor Or one Actor (+) A maximum of 1 reader at RF185C, 2 readers at RF186C/CI, 4 readers at RF188C/CI of MV500 may be connected adapting cable: 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 And extension cables: 2 m = 6GT2 891-4FH20 5 m = 6GT2 891-4FH50 10 m = 6GT2 891-4FN10 20 m = 6GT2 891-4FN20 50 m = 6GT2 891-4FN50 Types of IO-Link I/O module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed MV540 S; 800 x 600 pixel: (6GF3540-0CD10) H; 1280 x 1024 pixel: (6GF3540-0GE10) MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) s) sh) 1) sh) ux) 1) 4) sh) ux) 1) 4) sh) ux) 1) 4) shux) shux) Lights external Red: 6GF3400-0LT01-8DA1 Infrared: 6GF3400-0LT01-7BA1 adapter M12/M12 (6GF3500-8BD10) Mounting plate (6GF3440-8CD01) + + Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 MV500 System Interfaces Edition: July 2022 MV500 System Interfaces 62 Serial RS232 RS 232 cable for MV500 (open wires) 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 1 Reader per COM port may be connectedTerminal box / switching cabinet 24VDC IN 24VDC OUT RS232 RS232 DI/DO DI/DO (opt.) SIMATIC Ident Configuration Guide Simple text based protocol 62 + MV530 S; 800 x 600 pixel: (6GF3530-0CD10) H; 1280 x 1024 pixel: (6GF3530-0GE10) Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 or Reader With external power supply Options DO Wires included in power supply cable Open wires Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Pat-Genius 6GF3400-0SL03 Edition: July 2022 63 Serial RS232 RS 232 cable for MV500 (open wires) 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 1 Reader per COM port may be connectedTerminal box / switching cabinet 24VDC IN 24VDC OUT RS232 RS232 DI/DO DI/DO (opt.) SIMATIC Ident Configuration Guide Simple text based protocol 63 + Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed MV540 S; 800 x 600 pixel: (6GF3540-0CD10) H; 1280 x 1024 pixel: (6GF3540-0GE10) MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Options DO Wires included in power supply cable Open wires Reader With external power supply Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights external: ring Red: 6GF3400-0LT01-8DA1 Infrared: 6GF3400-0LT01-7BA1 adapter M12/M12: 6GF3500-8BD10 mounting plate: 6GF3440-8CD01 + E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) s) sh) 1) sh) ux) 1) 4) sh) ux) 1) 4) sh) ux) 1) 4) shux) shux) Lights external: panel 20x20 cm: 6GF3500-8DF30-1DA0 30x20 cm: 6GF3500-8DF30-2DA0 40x30 cm: 6GF3500-8DF30-3DA0 Mounting aid 6GF3500-8CD + MV500 System Interfaces Edition: July 2022 Ethernet TCP/IP + + S7-300/1500 via Industrial Ethernet or PROFINET S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 + + S7-1200 via Industrial Ethernet or PROFINET + + S7-1200 CPU + CSM 377 (6GK7 377-1AA00-0AA0) ++ Direct connection (1 reader may be connected) A maximum of 3 readers may be connected Direct connection (1 reader may be connected) + + A maximum of 3 readers may be connected)++ CSM 1277 (6GK7 277-1AA10-0AA0) Direct connection MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) ++++ + Network Connection via Compact Switch Module Network Connection via Compact Switch Module 64 MV500 Ethernet Connection Cable length form 0.3 m to15 m available e.g. 2 m = 6XV1870-8GH20 or MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable length from 2 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) (no switch required) SIMATIC Ident Configuration Guide Use library Ident Profile Use library Ident Profile Use native TCP/IP with text based commands Network Connection via Switch IP 20: IE switch SCALANCE X (6GK5 ) IP 65: IE switch SCALANCE XP208 (6GK5208-0HA00-2AS6) Reader With external power supply MV540 S; 800 x 600 pixel: (6GF3540-0CD10) H; 1280 x 1024 pixel: (6GF3540-0GE10) MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Options DO Wires included in power supply cable Open wires Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed Lights external: ring Red: 6GF3400-0LT01-8DA1 Infrared: 6GF3400-0LT01-7BA1 adapter M12/M12: 6GF3500-8BD10 mounting plate: 6GF3440-8CD01 + Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) ³) Custom assembly necessary; use the correct stripping tool or Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) s) sh) 1) sh) ux) 1) 4) shu) ux) 1) 4) sh) ux) 1) 4) shux) shux) Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights external: panel 20x20 cm: 6GF3500-8DF30-1DA0 30x20 cm: 6GF3500-8DF30-2DA0 40x30 cm: 6GF3500-8DF30-3DA0 Mounting aid 6GF3500-8CD + MV500 System Interfaces Edition: July 2022 Ethernet TCP/IP or PROFINET (PoE): 100MB Network Connection via SCALANCE Switches PoE IE switch SCALANCE X108 PoE (6GK5108-0PA00-2AA3) ++++ length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 S7-1200 CPU PC IE switch SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) IE switch SCALANCE XR324-4M PoE (e.g. 6GK5324-4QG00-3AR2) SIMATIC Ident Configuration Guide Use native TCP/IP with text based commands Use library Ident Profile Use library Ident Profile IE switch SCALANCE XP208 PoE EEC (6GK5208-0UA00-5ES6) or or or or IE switch SCALANCE XP216 PoE EEC (6GK5216-0UA00-5ES6) 65 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901- 1BB10-2AA0 ³) + MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) ³) Custom assembly necessary; use the correct stripping tool MV530 S; 800 x 600 pixel: (6GF3530-0CD10) H; 1280 x 1024 pixel: (6GF3530-0GE10) Cable for power supply Open wires 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Power supply EU connector 6GT2 898-0AA00 US connector 6GT2 898-0AA20 UK connector 6GT2 898-0AA10 cable for 24 V 5 m = 6GT2 891-0PH50 + 50 cm = 6GF3500-8BA11 5 m = 6GF3500-8BA12 or Reader With external power supply Options DO Wires included in power supply cable Open wires Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Software Pat-Genius 6GF3400-0SL03 MV500 System Interfaces Edition: July 2022 Two parallel Networks on one Device: 1000MB + 100MB Network Connection via SCALANCE Switches PoE IE switch SCALANCE X108 PoE (6GK5108-0PA00-2AA3) ++++ MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 + 6GK1901-1BB10-2AA0 ³) length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 PC IE switch SCALANCE X308-2M PoE (6GK5308-2QG00-2AA2) or IE switch SCALANCE XR324-4M PoE (e.g. 6GK5324-4QG00-3AR2) SIMATIC Ident Configuration Guide Use native TCP/IP with text based commands IE switch SCALANCE XP208 PoE EEC (6GK5208-0UA00-5ES6) or or IE switch SCALANCE XP216 PoE EEC (6GK5216-0UA00-5ES6) 66 +MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1870-8GH20 Reader With power supply over Ethernet (PoE)1000MB / GigE Network, no PoE needed 100 MB / Profinet Network, Switch with PoE MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) MV500 Ethernet Connection Cable length from 0.3 to 15 m available e.g. 2 m = 6XV1878-5GH20IP 65: IE switch SCALANCE XP216 (e.g. 6GK5216-0HA00-2AS6) Direct connection MV500 Ethernet Connection Cable length from 0.3 to 15 m available; e.g. 2 m = 6XV1878-5GH20 + 6GK1901-1BB12-2AA0 ³) (no switch required) Network Connection via Switch IP 20: IE switch SCALANCE X GB (e.g. 6GK5208-0GA00-2AC2) S7-1500 CPU or S7-300 CPU or S7-300 with CP343-1 S7-1200 CPU Use library Ident Profile Use library Ident Profile PC Use native TCP/IP with text based commands ++ ++ length from 0.5 to 50 m available e.g. 2 m = 6XV1870-3QH20 + + ++ or ³) Custom assembly necessary; use the correct stripping tool 1) not in combination with build-in lights; ²) use long version of protective lens cover always and only with 6GF9001-1BK01 and 6GF3540-8EA05-0LL0 4) No usage of option Micro SD Card with these lens shux) indicates the types of camera which are allowed for usage; i.e. u) means MV5x0U is allowed Options DO Additional cable for DO-supply is needed 10 m = 6GF3500-8BA21 30 m = 6GF3500-8BA41 Micro SD Card for Configuration Backup; 4GB 6GK6000-8HT01-0SA2 Support Mounting plate 6GF3440-8CA Tri-plate 6GF9002-7AD Opt. for Lens; Rings 0.5, 1, 5, 10, 20, 40 mm 6GF9001-1BU 0.5, 1 mm 6GF9001-1BU01 length doubler 6GF9001-1BV Protective lens cover Basic length glas no filter 6GF3540-8AC11 red 6GF3540-8AC51 infrared 6GF3540-8AC41 IRUVcut 6GF3540-8AC31 Long version glas ²) no filter 6GF3540-8AC12 red 6GF3540-8AC52 infrared 6GF3540-8AC42 IRUVcut 6GF3540-8AC32 Basic length PMMA 6GF3540-8AC21 Long version PMMA ²) 6GF3540-8AC22 MV550 S; 800 x 600 pixel: (6GF3550-0CD10) H; 1280 x 1024 pixel: (6GF3550-0GE10) MV560 U; 1920 x 1200 pixel: (6GF3560-0LE10) X; 2592 x 2048 pixel: (6GF3560-0HE10) Manual focus lens 6 mm: 6GF9001-1BB01 8.5 mm: 6GF9001-1BE01 12 mm: 6GF9001-1BL01 12 mm: 6GF3560-8EA01-0FF0 16 mm: 6GF9001-1BF01 16 mm: 6GF3560-8EA02-0FF0 25 mm: 6GF9001-1BG01 25 mm: 6GF3560-8EA03-0FF0 35 mm: 6GF9001-1BH01 50 mm: 6GF9001-1BJ01 75 mm: 6GF9001-1BK01 shux) ²) E-Focus lens 12 mm: 6GF3540-8EA01-0LL0 sh) 16 mm: 6GF3540-8EA02-0LL0 shu) 25 mm: 6GF3540-8EA03-0LL0 shux) 35 mm: 6GF3540-8EA04-0LL0 shux) 50 mm: 6GF3540-8EA05-0LL0 shux) ²) s) sh) 1) sh) ux) 1) 4) shu) ux) 1) 4) sh) ux) 1) 4) shux) shux) Software Veri-Genius 6GF3400-0SL02 Pat-Genius 6GF3400-0SL03 Lights build-in red basic: 6GF3540-8DA11 red far: 6GF3540-8DA12 red multi: 6GF3540-8DA13 white multi: 6GF3540-8DA33 infrared basic: 6GF3540-8DA41 infrared far 6GF3540-8DA42 MV500 System Interfaces Edition: July 2022 MV320, MV326 System Interfaces 67 Reader Powered through USB-cable Options SIMATIC Ident Configuration Guide MV320 (6GF3320- 0HT01) MV326 with Docking station (6GF3326-0HT01) PC PC via USB 1 Reader per USB port may be connected USB cable for MV320/ MV326 The USB-cable (1.8 m) is included in the delivery scope Metal stand for MV320 (6GF3320-0AC07) Spare Battery for MV326 (6GF3326-0AC07 *) RF170C Communication module (6GT2 002-0HD01) Connection block (6GT2 002-1HD01) RF170C RS 232 cable for MV320 1.6 to 4 m = 6GT2191-0BH50 A maximum of 2 readers may be connected + ET200pro via PROFIBUS or PROFINET or S7 PLC ET200pro PROFIBUS DP-V1 Interface module ET200pro PROFINET Interface module Up to 9 x 170C modules per ET200pro rack ET200pro PROFINET CPU module MV320 (6GF3320-0HT01) Reader Powered through connection cable Panel PC SIMATIC PLC S7-1200 A maximum of 1 readers may be connected +RF120C to MV320 1.6 to 4 m = 6GT2191-1BH50+ RF120C 6GT2 002-0LA00 Up to 3 x RF120C modules per S7-1200 rack * planned Edition: July 2022 MV320, MV326 System Interfaces 68 Options SIMATIC Ident Configuration Guide Metal stand for MV320 (6GF3320-0AC07) RS 232 cable for MV320 1.6 to 4 m = 6GT2191-0BH50 MV320 (6GF3320-0HT01) Reader Powered through connection cable PROFIBUS + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) A maximum of 2 readers may be connected + ++ PROFINET & Ethernet/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + Or one Standard sensor Or oneActor RS 232 cable for MV320 1.6 to 4 m = 6GT2191-0BH50 A maximum of 1 reader at RF185C, 2 readers at RF186C/CI, RF188C/CI of MV300 may be connected Types of IO-Link IO module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) RS232 For SIMATIC and other PLC + 5V cable via USB 1m = 6GT2091-7UH10 + use an already available and unused USB port or standard USB power supply from the market power supply RS 232 cable for MV320 6GF3320-0AC03 1 Reader per RS232 port may be connected i.e. S7-1500 CPU CM PtP RS 232 BA (6ES7540-1AD00-0AA0) Reader With external power supply MV320 (6GF3320-0HT01) + Edition: July 2022 System Interfaces for general purpose serial devices (RS232 or RS422) 69 Serial device powered through connection cable SIMATIC Ident Configuration Guide Options ++ PROFINET & Ethernet/IP RF185C (6GT2 002-0JE10) RF186C (6GT2 002-0JE20) RF188C (6GT2 002-0JE40) Communication Modules Additional IOs RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + Or one Standard sensor Or one Actor A maximum of 1 serial device at RF185C, 2 serial devices at RF186C/CI, 4 serial devices at RF188C/CI** may be connected via RS232* or RS422 PROFIBUS + RF166C (DP-V1) Communication Module (6GT2 002-0EE20) A maximum of 2 readers may be connected +RF166C to serial device via RS232* or RS422 Serial device powered with external power supply *) always use short cables (maximum 5 m) when using 5V power supply from CM **) on RS232 usage: only 2 serial devices can be connected Provided power from CM: 24 Volt up to 800 mA for each device 5 Volt * (only when RS232 is used) up to 500 mA for each device Always refer to the manual of the connected device Cabling: Use a bulk cable (i.e. 6GT2090-4AN50) and assemble left side the CM connector 6GT2090-0BE00 The right side connector you may order via distributor for electronic components Or Use the cable delivered by th device, cut the left side connector and replace it with a plug 6GT2090-0BE00 Or (only RS422) You may use one of the standard reader cable 6GT2891-4F, cut and replace the connector on the right side (device side) Provided power: Always customer specific power supply RF170C Communication module (6GT2 002-0HD01) Connection block (6GT2 002-1HD01) RF170C A maximum of 2 readers may be connected + ET200pro via PROFIBUS or PROFINET or S7 PLC ET200pro PROFIBUS DP-V1 Interface module ET200pro PROFINET Interface module Up to 9 x 170C modules per ET200pro rack ET200pro PROFINET CPU module Examples of devices: Examples of devices: Types of IO-Link I/O module IO-extension module 6ES7 14.. (up to 8xDI + 8xDO) See page 76 for detailed information RF18xCI to sensor Sensor cable from 0.5 to 15 m available (e.g. 2 m = 6XV1801-2CH20) RF170C to serial device via RS232* or RS422+ + Customer assembled cable: CM connector (6GT2090-0BE00) Bulk cable i.e. 50 m (6GT2 090-4AN50) Device connector (Order via distributor) Customer assembled cable: CM connector (6GT2090-0BE00) Bulk cable i.e. 50 m (6GT2 090-4AN50) Device connector (Order via distributor) Customer assembled cable: CM connector (6GT2090-0BE00) Bulk cable i.e. 50 m (6GT2 090-4AN50) Device connector (Order via distributor) i.e. scanners, handheld devices i.e. robots, motors, tooling machines Edition: July 2022 Description Part Number Notes RF185C RF186C RF188C RF186CI RF188CI 6GT2 002-0JE10 6GT2 002-0JE20 6GT2 002-0JE40 6GT2 002-0JE50 6GT2 002-0JE60 1 read/write device or reader 2 read/write devices or readers 4 read/write devices or readers 2 read/write devices or readers plus sensors 4 read/write devices or readers plus sensors can be connected to PROFINET or Ethernet (OPC UA) Make your own M12 PROFINET connection cables SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0 Ethernet to CM. 2 x M12 4-pin connectors needed if loop-through RJ45 connector with metal casing and FC connection system, 180° cable outlet 6GK1 901-1BB10-2AA0 For connection into standard RJ45-type Ethernet switch ETHERNET industrial cable 2x2, Type A, unassembled 6XV1 840-2AH10 Sold by the meter Minimum length 20 m; Maximum length 1000 m Use pre-made M12 PROFINET connection cables Pre-assembled PROFINET cable with 4-pin M12 on both ends 6XV1 870-8Axxx* 6XV1 870-8Gxxx* 8A = 180°, 8G = 90° 0.3 m 15 m pre-assembled cable Pre-assembled PROFINET cable with 4-pin M12 / RJ45 6XV1871-5Txxx* 0.3 m 15 m pre-assembled cable RJ45 for switch / PC / controller Make your own M12 L-coded power supply connection cables Power cable (4 wire x 1.5 mm2, trailing type) 6XV1801-2B For the supply of the 24 VDC power, from 20m up to 1000m M12 L-coded male connector 6GK1906-0EA00 For the loop-through of the 24 VDC power, screw joint for wires up to 1.5 mm2 M12 L-coded female connector 6GK1906-0EB00 For the supply side of 24 VDC power, screw joint for wires up to 1.5 mm2 Use pre-made M12 L-coded power supply connection cables Cable for supply voltage with pre- Assembled M12 L-coded connectors 180° 6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m Cable for supply voltage with pre- Assembled M12 L-coded connectors 90° 6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m Cable for supply voltage assembled with M12 A-coded 4pin male connector and M12 L-coded connector female at CM side 6GT2091-0PH50 Length 5 m Useful to connect the CM directly to a power supply of type 6GT2898-0ACx0 Description Part Number Notes Make your own RF18xC to RF reader cables Refer to the Bulk cable and connectors tables (Pages 79 - 80) Use pre-made RF18xC to RF reader cables Reader cable R200/ RF300/ MV440 or Extension cable for RF200/ RF300/ MV400 /MV500 6GT2 891-4FH20 2 meter pre-assembled cable 6GT2 891-4FH50 5 meter pre-assembled cable 6GT2 891-4FN10 10 meter pre-assembled cable 6GT2 891-4FN20 20 meter pre-assembled cable 6GT2 891-4FN50 50 meter pre-assembled cable Reader cable to RF1000 6GT2891-4UH20 2 meter pre-assembled cable Reader cable to MV320 6GT2191-0BH50 5 meter pre-assembled coiled cable with a usable length between 1.6 and 4 meter Reader cable MV420 6GF3420-0AC00-2CB0 2 meter pre-assembled cable Reader cable MV500 6GF3500-8BA11 0.5 meter pre-assembled cable 6GF3500-8BA12 5 meter pre-assembled cable Additional components Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items Labels 10 x 5 mm for CM channel marking 6ES7194-2BA00-0AA0 For additional marking. Per default labels are included in CM package Make your own M12 sensor cable (only RF18xCI variants) M12 A-coded male connector, 4 pin 6GK1 907-0DB10-6AA3 Sensor Connector at CM-side for cable diameter 6 8 mm M12 A-coded female connector, 4 pin 6GK1 907-0DC10-6AA3 Sensor-side connector for cable diameter 6 8 mm Sensor cable five wire 6XV1801-2C bulk cable; minimum order 20 meter M12 A-coded male connector, 5 pin, 180° 6GK1 908-0DB10-6AA0 Sensor connector at CM-side Required for assembling an IO-Link port Class B cable M12 A-coded female connector, 5 pin, 180° 6GK1 908-0DC10-6AA0 Sensor connector at sensor-side Use pre-made M12 sensor cable (only RF18xCI variants) IO-Link (port Class B) sensor cable with M12 A-coded 5-pin connectors (male and female) 6XV1801-2Cxxx* Lengths available from 0.5 m up to 15 m 70 RF18xC /CI Bill of Materials Guide The RF18xC is a communication module that can connect to Ethernet-based networks via an M12 d-coded connector. It supports a variety of protocols like PROFINET, Ethernet/IP, OPC UA, TCP/IP. A integrated switch enables star and line topologies. The module has L-coded M12 connectors for the 24 V power supply. The power can be transferred to additional loads at a second L-coded female connector. The L-coded connectors can transmit a continuous current of up to 16 A. The designer chooses whether to purchase pre-made network cables or to make his/her own. Note that no Termination Resistors are required on end-nodes, but covering caps are highly recommended. Bus Topology Concept RF185C RF186C/CI RF188C/CIReader Reader 24VDC Power Covering cap Covering cap SIMATIC Ident Configuration Guide * These cables are available in various lengths (see catalogue or mall) Reader PROFINET Edition: July 2022 Description Part Number Notes RF186CI RF188CI 6GT2 002-0JE50 6GT2 002-0JE60 2 read/write devices or readers plus sensors 4 read/write devices or readers plus sensors can be connected to PROFINET or Ethernet (OPC UA) 71 RF18xCI Bill of Materials Guide, Sensor Cabling The RF18xCI variants allow the connecting of a variety of IO-Link I/O modules. A maximum of 8 sensors (inputs) and 8 actors (outputs) may be connected to one CM. There is no additional configuration necessary for the I/Os. The I/Os can be used with all available protocols: PROFINET, Ethernet/IP, OPC UA and TCP/IP. Read this page for connecting details. The designer chooses whether to purchase pre-made sensor cable or to make his/her own (see page before) SIMATIC Ident Configuration Guide RF186CI (6GT2 002-0JE50) RF188CI (6GT2 002-0JE60) + + RF18xCI to IO-Link I/O module or sensor, actor 0.5 m = 6XV1801-2CE50 1 m = 6XV1801-2CH10 1.5 m = 6XV1801-2CH15 2 m = 6XV1801-2CH20 3 m = 6XV1801-2CH30 5 m = 6XV1801-2CH50 10 m = 6XV1801-2CN10 15 m = 6XV1801-2CN15 *) Some IO modules for high output current need an extra L- coded power cable 6XV1801-6Dxxx from 0.5 to 15 m I/O modules with M12 sensor connectors 6ES7 141-5AH00-0BL0 (8xDI) 6ES7 143-5AH00-0BL0 (8xDI + 8xDO) One standard sensor Or one actor, lamp I/O modules with M8 sensor connectors 6ES7 141-5BF00-0BL0 (8xDI) 6ES7 143-5BF00-0BL0 (4xDI + 4xDO) I/O module to sensor 0.5 m = 6XV1801-2CE50 1 m = 6XV1801-2CH10 1.5 m = 6XV1801-2CH15 2 m = 6XV1801-2CH20 3 m = 6XV1801-2CH30 5 m = 6XV1801-2CH50 10 m = 6XV1801-2CN10 15 m = 6XV1801-2CN15 + + I/O module to sensor Use sensor cables from the sensor market + +Sensor/actor cabling 6ES7 142-5AF00-0BL0 (8xDO, 2A) Extra M12 L-coded power cable needed *) I/O modules with integrated sensor/actor 8WD4428-0BF (SIRIUS Signaling column) For detailed configuration read manual: https://support.industry.siemens.com/cs/ww/en/view/109758131 3SU1400. (Pushbuttons and indicator lights from SIRIUS ACT) 3SU1400-1HL10-6AA0 (6xDI + 2xDO) 3SU1400-2HL10-6AA0 (6xDI + 2xDO) 3SU1400-2HK10-6AA0 (6xDI + 2xDO) 3SU1400-2HM10-6AA0 (4xDI + 4xDO) 3SU1400-2HN10-6AA0 (2xDI + 6xDO) For detailed configuration read manual: https://support.industry.siemens.com/cs/ww/en/view/107542462 Bus Topology Concept RF186CI RF186CI Reader 24VDC Power PROFINET Reader Sensors, actors Sensors, High power actors *) Edition: July 2022 Description Part Number Notes RF166C 6GT2 002-0EE20 For PROFIBUS DP-V1 networks. 2 read/write devices or readers can be connected The devices may have RS422 or RS232 interface Make your own M12 PROFIBUS connection cables PROFIBUS M12 connector plug (5 per pack) with socket insert 6GK1 905-0EB00 For the supply side of the PROFIBUS network. Use Termination Resistor on the 2nd M12 port if RF166C is an end node PROFIBUS M12 connector plug (5 per pack) with pin insert 6GK1 905-0EA00 For loop-through side of the PROFIBUS network. Both ports are used. No Termination Resistor needed for that RF166C POFIBUS standard non-assembled cable 6XV1 830-0EH10 Sold by the meter Minimum length 20 m Maximum length 10000 m M12 Termination Resistor for PROFIBUS (5 per pack) 6GK1 905-0EC00 Required if RF166C is an end-node Use pre-made M12 PROFIBUS connection cables PROFIBUS cable with pre-assembled M12 connectors 6XV1 830-3Dxxx* See Online Mall (http://mall.automation.siemens.com) Lengths available from 0.5 m up to 15 m M12 Termination Resistor for PROFIBUS (5 per pack) 6GK1 905-0EC00 Required if RF166C is an end-node Make your own M12 L-coded power supply connection cables Power cable (4 wire x 1.5 mm2, trailing type) 6XV1801-2B For the supply of the 24 VDC power, from 20m up to 1000m M12 L-coded male connector 6GK1906-0EA00 For the loop-through of the 24 VDC power, screw joint for wires up to 1.5 mm2 M12 L-coded female connector 6GK1906-0EB00 For the supply side of 24 VDC power, screw joint for wires up to 1.5 mm2 Use pre-made M12 L-coded power supply connection cables Cable for supply voltage with pre- Assembled M12 L-coded connectors 180° 6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m Cable for supply voltage with pre- Assembled M12 L-coded connectors 90° 6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m Cable for supply voltage assembled with M12 A-coded 4pin male connector and M12 L-coded connector female at CM side 6GT2091-0PH50 Length 5 m Useful to connect the CM directly to a power supply of type 6GT2898-0ACx0 Description Part Number Notes Make your own RF166C to RF reader cables Refer to the Bulk cable and connectors tables (Pages 79- 80) Use pre-madeRF166C to RF reader cables Reader cable R200/ RF300/ RF600 /MV440 or Extension cable for RF200/ RF300/ RF600/ MV400 /MV500 6GT2 891-4FH20 2 meter pre-assembled cable 6GT2 891-4FH50 5 meter pre-assembled cable 6GT2 891-4FN10 10 meter pre-assembled cable 6GT2 891-4FN20 20 meter pre-assembled cable 6GT2 891-4FN50 50 meter pre-assembled cable Reader cable to RF1000 6GT2891-4UH20 2 meter pre-assembled cable Reader cable to MV320 6GT2191-0BH50 5 meter pre-assembled coiled cable with a usable length between 1.6 and 4 meter Reader cable MV420 6GF3420-0AC00-2CB0 2 meter pre-assembled cable Reader cable MV500 6GF3500-8BA11 0.5 meter pre-assembled cable 6GF3500-8BA12 5 meter pre-assembled cable Additional components Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items Labels 10 x 5 mm for CM channel marking 6ES7194-2BA00-0AA0 For additional marking. Per default labels are included in CM package Make your own M12 Ethernet connection cables (needed for web-based management) SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0 Ethernet to RF166C. 2 x M12 4-pin connectors needed if loop-through RJ45 connector with metal casing and FC connection system, 180° cable outlet 6GK1 901-1BB10-2AA0 For connection into standard RJ45-type Ethernet switch ETHERNET industrial cable 2x2, Type A, unassembled 6XV1 840-2AH10 Sold by the meter Minimum length 20 m; Maximum length 1000 m Use pre-made M12 Ethernet connection cables (needed for web-based management) Pre-assembled Ethernet cable with 4-pin M12 at RF166C and RJ45 at computer 6XV1871-5Txxx* 2 m 15 m pre-assembled cable Use this cable type if the wbm of the RF166C is directly connected to a PC Pre-assembled PROFINET cable with 4-pin M12 on both ends 6XV1 870-8xxx* 0.3 m 15 m pre-assembled cable Use this cable type if the RF166C is connected to a IP 65 switch 72 RF166C Bill of Materials Guide The RF166C is a PROFIBUS DP-V1 interface module. The PROFIBUS connection is made via M12 B-coded connector. The module has L-coded M12 connectors for the 24 V power supply. The power can be transferred to additional loads at a second L-coded female connector. The L-coded connectors can transmit a continuous current of up to 16 A. The designer chooses whether to purchase pre-made network cables or to make his/her own. Note that another design consideration is whether the RF166C is a PROFIBUS end-node or not. If it is an end-node, a Termination Resistor is required. Bus Topology Concept RF166C RF166C RF166C PROFIBUS 24VDC Power Bus Termination Covering cap SIMATIC Ident Configuration Guide * These cables are available in various lengths (see catalogue or mall) Reader Reader Reader Edition: July 2022 Description Part Number Notes RF360R 6GT2801-5BA30 RF300 Reader with integrated antenna Make your own M12 PROFINET connection cables SIMATIC NET Ethernet M12 4-pin connector 6GK1 901-0DB10-6AA0 Ethernet to reader. 2 x M12 4-pin connectors needed if loop-through RJ45 connector with metal casing and FC connection system, 180° cable outlet 6GK1 901-1BB10-2AA0 For connection into standard RJ45-type Ethernet switch ETHERNET industrial cable 2x2, Type A, unassembled 6XV1 840-2AH10 Sold by the meter Minimum length 20 m; Maximum length 1000 m Use pre-made M12 PROFINET connection cables Pre-assembled PROFINET cable with 4-pin M12 on both ends 6XV1 870-8Axxx* 6XV1 870-8Gxxx* 8A = 180°, 8G = 90° 0.3 m 15 m pre-assembled cable Pre-assembled PROFINET cable with 4-pin M12 / RJ45 6XV1871-5Txxx* 0.3 m 15 m pre-assembled cable RJ45 for switch / PC / controller Make your own M12 L-coded power supply connection cables Power cable (4 wire x 1.5 mm2, trailing type) 6XV1801-2B For the supply of the 24 VDC power, from 20m up to 1000m M12 L-coded female connector 6GK1906-0EB00 For the supply side of 24 VDC power, screw joint for wires up to 1.5 mm2 Use pre-made M12 L-coded power supply connection cables Cable for supply voltage with pre- Assembled M12 L-coded connectors 180° 6XV1801-6Dxxx* Lengths available from 0.5 m up to 15 m Cable for supply voltage with pre- Assembled M12 L-coded connectors 90° 6XV1801-6Gxxx* Lengths available from 0.5 m up to 15 m Cable for supply voltage assembled with M12 A-coded 4pin male connector and M12 L-coded connector female at CM side 6GT2091-0PH50 Length 5 m Useful to connect the reader directly to a power supply of type 6GT2898-0ACx0 Description Part Number Notes Additional components Covering caps for unused M12 ports 3RX9 802-0AA00 1 pack = 10 items 73 RF360R Bill of Materials Guide The RF360R is a reader from the RF300 family that can connect to Ethernet- based networks via an M12 d-coded connector. It supports a variety of protocols like PROFINET, Ethernet/IP, OPC UA, TCP/IP. A integrated switch enables star and line topologies. The module has L-coded M12 connectors for the 24 V power supply. The designer chooses whether to purchase pre-made network cables or to make his/her own. Note that no Termination Resistors are required on end-nodes, but covering caps are highly recommended. Bus Topology Concept RF360R RF360R RF360R 24VDC Power Covering cap SIMATIC Ident Configuration Guide * These cables are available in various lengths (see catalogue or mall) PROFINET Edition: July 2022 RF166C RF120C ASM 475 RS232 to PC Ethernet to PC RF170C RF185C, RF186C/CI, RF188C/CI RF200 RF2x0R (IO-Link) For IP 20 Master with screws or push in: 6XV1 801-2C (5 wire sensor cable; minimum order 20 m) 6GK1 908-0DC10-6AA0 (reader connector; never assemble pin 2) For IP 67 Master with M12: 6XV1 801-2C (5 wire sensor cable; minimum order 20 m) 6GK1 908-0DC10-6AA0 (reader connector; never assemble pin 2) 6GK1 908-0DB10-6AA0 (IO-Link master connector) RF2X0R RF210M (RS422) (CM type) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 9-pin submin-D/M (CM connector)1 6GT2090-4AN50 (50 m cable) 6GT2090-4AT12 (120 m cable) 6GT2090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 20-pin S7-300 (CM connector) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) PC side: interface converter RS422/ RS232 Not applicable 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) RF240R RF250R RF260R RF285R RF290R (RS232) Not applicable Not applicable Not applicable 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2 490-1AA00 (PC connector) Not applicable Not applicable Not applicable RF300 RF3x0R (RS422) (CM type) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 9-pin submin-D/M (CM connector)1 6GT2090-4AN50 (50 m cable) 6GT2090-4AT12 (120 m cable) 6GT2090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 20-pin S7-300 (CM connector) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) PC side: interface converter RS422/ RS232 Not applicable 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) RF38xR (RS232) Not applicable Not applicable Not applicable 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2 490-1AA00 (PC connector) Not applicable Not applicable Not applicable RF600 RF650R Not applicable Not applicable Not applicable Not applicable 6XV1 840-2AH10 (>20 m cable) 6GK1901-1BB10-2AA0 (RJ45, reader connector + network connector) Not applicable Not applicable RF610R/ RF615R/ RF680R/ RF685R 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GT2090-0BE00 (CM connector) Not applicable Not applicable Not applicable 6XV1 840-2AH10 (>20 m cable) 6GK1901-0DB20-6AA0 (M12 Plug, reader connector) 6GK1901-1BB10-2AA0 (RJ45, network connector) Not applicable Not applicable RF1000 RF1040R/ RF1070R Always use assembled cables: 6GT2891-4UH20 (2m) Always use assembled cables: 6GT2891-6UH20 (2m) Not applicable Always use assembled cables: 6GT2891-2UH30 (3m, open) 6GT2891-7UH18 (1.8m, sub-D) Not applicable Always use assembled cables 6GT2891-4UH20 (2m) Always use assembled cables: 6GT2891-4UH20 (2m) 74 Bulk Cable and Connectors SIMATIC Ident Configuration GuideEdition: July 2022 RF166C RF120C ASM 475 RS232 to PC Ethernet to PC RF170C RF185C, RF186C/CI, RF188C/CI MV500 MV500 Always use reader-side assembled cables: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41 6GT2090-0BE00 (CM connector) Always use reader-side assembled cables: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41 9-pin submin-D/M (CM connector)1 Always use reader-side assembled cables: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41 20-pin S7-300 (CM connector) Always use reader-side assembled cables: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41 6GT2 490-1AA00 (PC connector) Always use reader-side assembled cables with 90° angled connector 100 MB: 6XV1 870-8xxx (0.3 to 15 m) 6GK1 901-1BB10-2AA0 (RJ45, 2x2) 6GK1 901-0DB20-6AA0 (M12, 2x2) 1000 MB: 6XV1 878-5Gxxx (0.3 to 15 m) 6GK1 901-1BB12-2AA0 (RJ45, 4x2) 6GK1 901-0DB30-6AA0 (M12, 4x2) The connectors (M12, RJ45) can be assembled after cutting one connector of an existing cable Always use reader-side assembled cables: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41 6GT2090-0BE00 (CM connector) Always use reader-side assembled cables: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41 6GT2090-0BE00 (CM connector) 75 Bulk Cable and Connectors 1. Order via distributor for electronic components SIMATIC Ident Configuration Guide Power & Control-side Networking Components RF166C RF120C ASM 475 RS232 to PC RF185C, RF186C/CI, RF188C/CI RF360R RF600 MV500 Cable & Connec-tors See RF166C Bill of Materials Guide Page 77 Direct with S7- 1200 assembly Direct in S7-300 rack or in ET 200M rack using IM153-2 Module See individual readers above See RF18xC bill of materials guide page 75 See RF360R bill of materials guide page 78 6GT2 090-4AN50 (50 m cable) 6GT2 090-4AT12 (120 m cable) 6GT2 090-4AT80 (800 m cable) 6GT2090-0BD00 (reader connector) 6GK1907-0DB10-6AA3 (power supply) Always use reader-side assembled cables (M12, 12pin) and power-side open ends: 10 m = 6GF3 500-8BA21 30 m = 6GF3 500-8BA41","libVersion":"0.3.2","langs":""}