// Block Type: FC
// Block Name (Original): ITC Communic Filler
// Block Number: 3512
// Original Network Languages: LAD

FUNCTION "ITC_Communic_Filler" : Void
{ S7_Optimized_Access := 'TRUE' }
VERSION : 0.1

VAR_TEMP
  #_200MS : Bool; // Auto-generated temporary
  #_500MS : Bool; // Auto-generated temporary
END_VAR

BEGIN

  // Network 1:  (Original Language: LAD)

  IF Eq("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_SignalExchange", 1) THEN
    "ITC Communic Filler DI"(ACTIVE := FALSE, ID := 1, INIT := "FirstScan", ISO_on_TCP_LOCAL_CPU_SLOT := 2, ISO_on_TCP_PN_PN := TRUE, ISO_on_TCP_REMOTE_CPU_SLOT := 2, LOCAL_PORT := 1, LOCAL_DEVICE_ID := 72, REMOTE_PORT := 2, REMOTE_IP_1 := 10, REMOTE_IP_2 := 1, REMOTE_IP_3 := 20, REMOTE_IP_4 := 11, REQ := FALSE, TCP_PROTOCOL := FALSE, TIME_ACT_SP := T#200MS, TIME_ALARM_SP := T#500MS, TRCV_DATA := "Interlocking_Variables"."FILLER_MIXER_RECEIVE", TRCV_ENABLE := TRUE, TRCV_LEN := 40, TSEND_DATA := "Interlocking_Variables"."MIXER_FILLER_SEND", TSEND_LEN := 40);
  END_IF;

  // Network 2: Communication Mixer - Filler (Original Language: LAD)

  // Network 2 did not produce printable SCL code.

  // Network 3:  (Original Language: LAD)

  // Network 3 has no logic elements.