FUNCTION_BLOCK "Signal Gen"
{ S7_Optimized_Access := 'FALSE' }
AUTHOR : 'Author'
FAMILY : TASK0
NAME : 'Name'
VERSION : 1.0
VAR
mRampOut : Real;
mRamp : "SlewLimit";
END_VAR
BEGIN
(* classic code: #mRamp(i_InValue := 0.4 * "Blender_Variables".gBlenderNomSpeed * BOOL_TO_INT ("gClock_120s"),
i_SlewMax:=(0.4 * "Blender_Variables".gBlenderNomSpeed / 10),
i_Cycle := "Time_50ms",
out := #mRampOut) ;*)
#mRamp(i_InValue := REAL#0.4 * "Blender_Variables".gBlenderNomSpeed * BOOL_TO_INT ("gClock_120s"),
i_SlewMax:=(REAL#0.4 * "Blender_Variables".gBlenderNomSpeed / 10),
i_Cycle := "Time_50ms",
out := #mRampOut) ;
IF "Procedure_Variables".First_Production.Done AND NOT "gBlenderAlarm" AND "gIN_Filler1ProductReq" THEN
(* classic code: "Blender_Variables".gFillerProductFlow := "Blender_Variables".gBlenderNomSpeed * 0.55 + #mRampOut ;*)
"Blender_Variables".gFillerProductFlow := "Blender_Variables".gBlenderNomSpeed * REAL#0.55 + #mRampOut ;
ELSE
"Blender_Variables".gFillerProductFlow := 0 ;
END_IF ;
END_FUNCTION_BLOCK