(3) is our trigger if the data changed, with this is possible to SET the (1) (1) is the TG10 Trigger to send the data with FB189

But the FB189 has a automatic mechanism to re-send data with the ENABLE_REPEAT

!Pasted image 20250213155258.png

You can check this counter (2) to see the number of re-send like "IDB2021_Autefa_Vetro_Line_25_Communication_DB".TG10_TG11.SEND_COUNTER

Here's a detailed table of telegrams exchanged with AUTEFA, including their required information and validation conditions:

Telegram Direction Purpose Main Content Required Information & Validation
TG10/TG11 VETRO → AUTEFA Production Information - Filling line
- Active batch ID
- Active batch target (thousands + units)
- Active Article Variant ID
- Next batch ID
- Next batch target
- Next Article Variant ID
- Next+1 batch information
- Filling line must be valid (11-16)
- Active batch targets must be >0
- Article Variant ID must exist in SKU list
- Batch IDs must be 12 characters
- Targets must be split into thousands/units
TG20/TG21 AUTEFA → VETRO Line/Product Change Request - Filling line
- Tray Loader (21-28)
- Requested Article Variant ID
- Accept/Reject status (TG21)
- Error code (TG21)
- TL must be available
- Article Variant ID must match current/next batch
- Conveyors must be in automatic mode
- No bottles required signal must be present
- Error codes:
0 = No error
1 = Conveyors not in auto
2 = Bottle type mismatch
3 = No bottles required
TG30/TG31 AUTEFA → VETRO End of Batch - Filling line
- Batch ID
- Article Variant ID
- Tray Loader
- Valid batch ID
- Active batch must be running
- TL must be assigned to line
- Article Variant ID must match current batch
TG40/TG41 VETRO → AUTEFA Speed Update - Filling line
- Line speed (1-100 in steps of 10)
- Speed must be between 0-100
- Speed changes limited to ±10 per update
- Line must be running
- No alarms active
TG50/TG51 VETRO → AUTEFA Activate Next Batch - Filling line
- Batch ID to activate
- Article Variant ID
- Next batch must be defined
- Article Variant ID must match next batch
- Current batch must be completing
- Line must be ready for changeover
TG60/TG61 VETRO → AUTEFA Request Unloaded Bottles Count - Filling line
- Batch ID
- Unloaded bottles count (TG61)
- Active batch must be running
- Counters must be operational
- Regular updates (typically every 60s)
- Count split into thousands/units

Additional Notes:

  • All telegrams have:
    • Fixed 100-byte length
    • 40-byte standard header containing:
      • Message length
      • Telegram number
      • Client ID
      • Timestamp
      • Error codes
    • Data integrity checks
    • Network timeout handling (10s default)
    • Retry mechanism (3 attempts)

Communication Rules:

  • Even-numbered telegrams are requests
  • Odd-numbered telegrams are responses/acknowledgments
  • Each telegram requires acknowledgment within timeout period
  • Repeated telegrams must maintain same header info
  • Error handling must be implemented for all scenarios
  • Data type conversions handled on VETRO side
  • Article Variant IDs used for simplified bottle type identification