--- Log de Ejecución: x1.py --- Grupo: ObtainIOFromProjectTia Directorio de Trabajo: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source Inicio: 2025-06-12 20:09:31 Fin: 2025-06-12 20:12:27 Duración: 0:02:55.810701 Estado: SUCCESS (Código de Salida: 0) --- SALIDA ESTÁNDAR (STDOUT) --- --- Exportador de datos TIA Portal (Bloques, UDTs, Variables) --- Versión de TIA Portal detectada: 19.0 (de la extensión .ap19) Proyecto seleccionado: D:/Trabajo/VM/44 - 98050 - Fiera/InLavoro/PLC/98050_PLC_07/98050_PLC_07.ap19 Usando directorio de exportación (Directorio de trabajo): D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source Conectando a TIA Portal V19.0... 2025-06-12 20:09:41,551 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Global OpenPortal - Start TIA Portal, please acknowledge the security dialog. 2025-06-12 20:09:41,566 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Global OpenPortal - With user interface Conectado a TIA Portal. 2025-06-12 20:10:05,539 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Portal GetProcessId - Process id: 35300 ID del proceso del Portal: 35300 Abriendo proyecto: 98050_PLC_07.ap19... 2025-06-12 20:10:05,793 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Portal OpenProject - Open project... D:/Trabajo/VM/44 - 98050 - Fiera/InLavoro/PLC/98050_PLC_07/98050_PLC_07.ap19 Proyecto abierto exitosamente. 2025-06-12 20:10:36,756 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Project GetPlcs - Found plc 98050_PLC with parent name ET 200SP station_1 Se encontraron 1 PLC(s). Iniciando proceso de exportación... --- Procesando PLC: 98050_PLC --- [PLC: 98050_PLC] Exportando bloques de programa... Destino XML: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source\98050_PLC\ProgramBlocks_XML Destino SCL: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source\98050_PLC\ProgramBlocks_SCL Se encontraron 291 bloques de programa. Procesando bloque: CyclicInterrupt_Axes... Exportando CyclicInterrupt_Axes como XML... 2025-06-12 20:10:50,870 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: CyclicInterrupt_Axes exported successfully 2025-06-12 20:10:50,872 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - CyclicInterrupt_Axes exported successfully Procesando bloque: DB HMI RCP Transfer Status... Exportando DB HMI RCP Transfer Status como XML... 2025-06-12 20:10:51,013 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI RCP Transfer Status exported successfully 2025-06-12 20:10:51,014 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI RCP Transfer Status exported successfully Procesando bloque: FC HMI RCP Transfer Status... Exportando FC HMI RCP Transfer Status como XML... 2025-06-12 20:10:52,007 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC HMI RCP Transfer Status exported successfully 2025-06-12 20:10:52,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC HMI RCP Transfer Status exported successfully Procesando bloque: FB Early Restart... Exportando FB Early Restart como XML... 2025-06-12 20:10:52,086 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Early Restart exported successfully 2025-06-12 20:10:52,086 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Early Restart exported successfully Procesando bloque: DB Signal Transport... Exportando DB Signal Transport como XML... 2025-06-12 20:10:52,164 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Signal Transport exported successfully 2025-06-12 20:10:52,165 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Signal Transport exported successfully Procesando bloque: DB Lube - Dry Ecolab... Exportando DB Lube - Dry Ecolab como XML... 2025-06-12 20:10:52,256 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Lube - Dry Ecolab exported successfully 2025-06-12 20:10:52,257 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Lube - Dry Ecolab exported successfully Procesando bloque: FB Lube - Water/Dry... Exportando FB Lube - Water/Dry como XML... 2025-06-12 20:10:52,320 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Lube - Water/Dry exported successfully 2025-06-12 20:10:52,320 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Lube - Water/Dry exported successfully Procesando bloque: FB Lube - Dry Ecolab... Exportando FB Lube - Dry Ecolab como XML... 2025-06-12 20:10:52,938 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Lube - Dry Ecolab exported successfully 2025-06-12 20:10:52,938 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Lube - Dry Ecolab exported successfully Procesando bloque: FB Lube - EcoLab VM... Exportando FB Lube - EcoLab VM como XML... 2025-06-12 20:10:53,086 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Lube - EcoLab VM exported successfully 2025-06-12 20:10:53,086 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Lube - EcoLab VM exported successfully Procesando bloque: FB Lube - Ecolab... Exportando FB Lube - Ecolab como XML... 2025-06-12 20:10:53,217 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Lube - Ecolab exported successfully 2025-06-12 20:10:53,218 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Lube - Ecolab exported successfully Procesando bloque: DB LUBE - Ecolab... Exportando DB LUBE - Ecolab como XML... 2025-06-12 20:10:53,266 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB LUBE - Ecolab exported successfully 2025-06-12 20:10:53,268 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB LUBE - Ecolab exported successfully Procesando bloque: FC Ttop Configuration... Exportando FC Ttop Configuration como XML... 2025-06-12 20:10:53,371 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Configuration exported successfully 2025-06-12 20:10:53,386 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Configuration exported successfully Procesando bloque: FC Ttop Run... Compilando bloque FC Ttop Run... 2025-06-12 20:10:53,392 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Run. Result: 2025-06-12 20:11:05,168 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:05,168 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:05,169 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Run (FC370) > Block was successfully compiled. Exportando FC Ttop Run como XML... 2025-06-12 20:11:05,244 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Run exported successfully 2025-06-12 20:11:05,245 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Run exported successfully Procesando bloque: FC Ttop Alarms... Compilando bloque FC Ttop Alarms... 2025-06-12 20:11:05,251 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Alarms. Result: 2025-06-12 20:11:06,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 1 > The address is not occupied by a tag. 2025-06-12 20:11:06,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 11 > The address is not occupied by a tag. 2025-06-12 20:11:06,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 11 > Called block "DB Ttop Motor 32" in network is not available. 2025-06-12 20:11:06,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 11 > Called block "DB Ttop Motor 34" in network is not available. 2025-06-12 20:11:06,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 11 > Called block "DB Ttop Motor 35" in network is not available. 2025-06-12 20:11:06,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 11 > Called block "DB Ttop Motor 36" in network is not available. 2025-06-12 20:11:06,178 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Network 12 > The address is not occupied by a tag. 2025-06-12 20:11:06,178 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:06,178 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 42) 2025-06-12 20:11:06,178 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > General > FC > FC Ttop Alarms (FC371) > Block was successfully compiled. ADVERTENCIA: Bloque FC Ttop Alarms inconsistente después de compilar. Omitiendo. Procesando bloque: DB Ttop Run... Exportando DB Ttop Run como XML... 2025-06-12 20:11:06,356 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Run exported successfully 2025-06-12 20:11:06,357 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Run exported successfully Procesando bloque: DB Ttop Motor CFG... Exportando DB Ttop Motor CFG como XML... 2025-06-12 20:11:06,394 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor CFG exported successfully 2025-06-12 20:11:06,395 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor CFG exported successfully Procesando bloque: DB Ttop Alarm... Exportando DB Ttop Alarm como XML... 2025-06-12 20:11:06,447 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Alarm exported successfully 2025-06-12 20:11:06,448 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Alarm exported successfully Procesando bloque: FC Ttop Motor M31510... Exportando FC Ttop Motor M31510 como XML... 2025-06-12 20:11:06,508 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31510 exported successfully 2025-06-12 20:11:06,509 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31510 exported successfully Procesando bloque: FC Ttop Motor U32810... Compilando bloque FC Ttop Motor U32810... 2025-06-12 20:11:06,511 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U32810. Result: 2025-06-12 20:11:07,810 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:07,811 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:07,812 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U32810 (FC306) > Block was successfully compiled. Exportando FC Ttop Motor U32810 como XML... 2025-06-12 20:11:07,952 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U32810 exported successfully 2025-06-12 20:11:07,954 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U32810 exported successfully Procesando bloque: FC Ttop Motor U32910... Compilando bloque FC Ttop Motor U32910... 2025-06-12 20:11:07,957 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U32910. Result: 2025-06-12 20:11:08,668 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:08,668 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:08,669 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U32910 (FC307) > Block was successfully compiled. Exportando FC Ttop Motor U32910 como XML... 2025-06-12 20:11:08,729 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U32910 exported successfully 2025-06-12 20:11:08,730 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U32910 exported successfully Procesando bloque: FC Ttop Motor U33010... Compilando bloque FC Ttop Motor U33010... 2025-06-12 20:11:08,735 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33010. Result: 2025-06-12 20:11:09,622 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:09,622 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:09,623 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33010 (FC308) > Block was successfully compiled. Exportando FC Ttop Motor U33010 como XML... 2025-06-12 20:11:09,665 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33010 exported successfully 2025-06-12 20:11:09,666 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33010 exported successfully Procesando bloque: FC Ttop Motor U33110... Compilando bloque FC Ttop Motor U33110... 2025-06-12 20:11:09,671 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33110. Result: 2025-06-12 20:11:10,395 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:10,396 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:10,396 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33110 (FC309) > Block was successfully compiled. Exportando FC Ttop Motor U33110 como XML... 2025-06-12 20:11:10,444 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33110 exported successfully 2025-06-12 20:11:10,458 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33110 exported successfully Procesando bloque: FC Ttop Motor U33210... Compilando bloque FC Ttop Motor U33210... 2025-06-12 20:11:10,461 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33210. Result: 2025-06-12 20:11:11,492 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:11,493 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:11,493 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33210 (FC310) > Block was successfully compiled. Exportando FC Ttop Motor U33210 como XML... 2025-06-12 20:11:11,565 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33210 exported successfully 2025-06-12 20:11:11,570 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33210 exported successfully Procesando bloque: FC Ttop Motor U33310... Compilando bloque FC Ttop Motor U33310... 2025-06-12 20:11:11,572 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33310. Result: 2025-06-12 20:11:12,423 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:12,423 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:12,424 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33310 (FC311) > Block was successfully compiled. Exportando FC Ttop Motor U33310 como XML... 2025-06-12 20:11:12,472 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33310 exported successfully 2025-06-12 20:11:12,473 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33310 exported successfully Procesando bloque: FC Ttop Motor U33410... Compilando bloque FC Ttop Motor U33410... 2025-06-12 20:11:12,475 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33410. Result: 2025-06-12 20:11:13,141 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:13,142 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:13,142 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33410 (FC312) > Block was successfully compiled. Exportando FC Ttop Motor U33410 como XML... 2025-06-12 20:11:13,196 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33410 exported successfully 2025-06-12 20:11:13,197 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33410 exported successfully Procesando bloque: FC Ttop Motor U33510... Compilando bloque FC Ttop Motor U33510... 2025-06-12 20:11:13,199 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33510. Result: 2025-06-12 20:11:14,259 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:14,260 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:14,260 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33510 (FC313) > Block was successfully compiled. Exportando FC Ttop Motor U33510 como XML... 2025-06-12 20:11:14,308 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33510 exported successfully 2025-06-12 20:11:14,308 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33510 exported successfully Procesando bloque: FC Ttop Motor U33610... Compilando bloque FC Ttop Motor U33610... 2025-06-12 20:11:14,311 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor U33610. Result: 2025-06-12 20:11:15,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:15,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:15,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor U33610 (FC314) > Block was successfully compiled. Exportando FC Ttop Motor U33610 como XML... 2025-06-12 20:11:15,049 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor U33610 exported successfully 2025-06-12 20:11:15,051 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor U33610 exported successfully Procesando bloque: FC Ttop Motor M34410... Compilando bloque FC Ttop Motor M34410... 2025-06-12 20:11:15,054 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M34410. Result: 2025-06-12 20:11:15,761 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:15,761 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:15,761 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor M34410 (FC319) > Block was successfully compiled. Exportando FC Ttop Motor M34410 como XML... 2025-06-12 20:11:15,800 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M34410 exported successfully 2025-06-12 20:11:15,801 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M34410 exported successfully Procesando bloque: FC Ttop Motor M31010... Compilando bloque FC Ttop Motor M31010... 2025-06-12 20:11:15,803 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31010. Result: 2025-06-12 20:11:16,662 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:16,663 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:16,664 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor M31010 (FC327) > Block was successfully compiled. Exportando FC Ttop Motor M31010 como XML... 2025-06-12 20:11:16,710 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31010 exported successfully 2025-06-12 20:11:16,711 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31010 exported successfully Procesando bloque: FC Ttop Motor M31410... Compilando bloque FC Ttop Motor M31410... 2025-06-12 20:11:16,713 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31410. Result: 2025-06-12 20:11:17,463 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:17,463 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:17,463 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > FC Ttop Motor M31410 (FC331) > Block was successfully compiled. Exportando FC Ttop Motor M31410 como XML... 2025-06-12 20:11:17,515 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31410 exported successfully 2025-06-12 20:11:17,517 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31410 exported successfully Procesando bloque: FC Ttop Motor M31310... Compilando bloque FC Ttop Motor M31310... 2025-06-12 20:11:17,520 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31310. Result: 2025-06-12 20:11:18,166 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:18,167 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:18,168 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31310 (FC330) > Block was successfully compiled. Exportando FC Ttop Motor M31310 como XML... 2025-06-12 20:11:18,207 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31310 exported successfully 2025-06-12 20:11:18,208 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31310 exported successfully Procesando bloque: FC Ttop Motor M30710... Compilando bloque FC Ttop Motor M30710... 2025-06-12 20:11:18,210 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M30710. Result: 2025-06-12 20:11:18,906 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:18,906 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:18,906 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M30710 (FC326) > Block was successfully compiled. Exportando FC Ttop Motor M30710 como XML... 2025-06-12 20:11:18,944 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M30710 exported successfully 2025-06-12 20:11:18,944 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M30710 exported successfully Procesando bloque: FC Ttop Motor M31110... Compilando bloque FC Ttop Motor M31110... 2025-06-12 20:11:18,946 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31110. Result: 2025-06-12 20:11:19,593 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:19,594 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:19,594 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31110 (FC328) > Block was successfully compiled. Exportando FC Ttop Motor M31110 como XML... 2025-06-12 20:11:19,638 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31110 exported successfully 2025-06-12 20:11:19,639 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31110 exported successfully Procesando bloque: FC Ttop Motor M31210... Compilando bloque FC Ttop Motor M31210... 2025-06-12 20:11:19,640 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31210. Result: 2025-06-12 20:11:20,347 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:20,348 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:20,348 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31210 (FC329) > Block was successfully compiled. Exportando FC Ttop Motor M31210 como XML... 2025-06-12 20:11:20,388 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31210 exported successfully 2025-06-12 20:11:20,389 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31210 exported successfully Procesando bloque: FC Ttop Motor M31610... Compilando bloque FC Ttop Motor M31610... 2025-06-12 20:11:20,391 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31610. Result: 2025-06-12 20:11:21,093 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:21,094 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:21,094 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31610 (FC302) > Block was successfully compiled. Exportando FC Ttop Motor M31610 como XML... 2025-06-12 20:11:21,134 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31610 exported successfully 2025-06-12 20:11:21,135 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31610 exported successfully Procesando bloque: FC Ttop Motor M31710... Compilando bloque FC Ttop Motor M31710... 2025-06-12 20:11:21,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31710. Result: 2025-06-12 20:11:21,800 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:21,801 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:21,801 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31710 (FC303) > Block was successfully compiled. Exportando FC Ttop Motor M31710 como XML... 2025-06-12 20:11:21,839 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31710 exported successfully 2025-06-12 20:11:21,840 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31710 exported successfully Procesando bloque: FC Ttop Motor M31810... Compilando bloque FC Ttop Motor M31810... 2025-06-12 20:11:21,842 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31810. Result: 2025-06-12 20:11:22,570 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:22,571 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:22,571 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31810 (FC304) > Block was successfully compiled. Exportando FC Ttop Motor M31810 como XML... 2025-06-12 20:11:22,614 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31810 exported successfully 2025-06-12 20:11:22,615 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31810 exported successfully Procesando bloque: FC Ttop Motor M31910... Compilando bloque FC Ttop Motor M31910... 2025-06-12 20:11:22,619 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M31910. Result: 2025-06-12 20:11:23,331 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:23,332 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:23,333 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M31910 (FC305) > Block was successfully compiled. Exportando FC Ttop Motor M31910 como XML... 2025-06-12 20:11:23,372 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M31910 exported successfully 2025-06-12 20:11:23,373 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M31910 exported successfully Procesando bloque: FC Ttop Motor M34010... Compilando bloque FC Ttop Motor M34010... 2025-06-12 20:11:23,374 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M34010. Result: 2025-06-12 20:11:24,055 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:24,056 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:24,056 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M34010 (FC315) > Block was successfully compiled. Exportando FC Ttop Motor M34010 como XML... 2025-06-12 20:11:24,111 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M34010 exported successfully 2025-06-12 20:11:24,112 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M34010 exported successfully Procesando bloque: FC Ttop Motor M34110... Compilando bloque FC Ttop Motor M34110... 2025-06-12 20:11:24,114 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M34110. Result: 2025-06-12 20:11:25,016 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:25,017 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:25,018 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M34110 (FC316) > Block was successfully compiled. Exportando FC Ttop Motor M34110 como XML... 2025-06-12 20:11:25,104 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M34110 exported successfully 2025-06-12 20:11:25,104 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M34110 exported successfully Procesando bloque: FC Ttop Motor M34210... Compilando bloque FC Ttop Motor M34210... 2025-06-12 20:11:25,108 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M34210. Result: 2025-06-12 20:11:25,897 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:25,897 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:25,897 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M34210 (FC317) > Block was successfully compiled. Exportando FC Ttop Motor M34210 como XML... 2025-06-12 20:11:25,943 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M34210 exported successfully 2025-06-12 20:11:25,943 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M34210 exported successfully Procesando bloque: FC Ttop Motor M34310... Compilando bloque FC Ttop Motor M34310... 2025-06-12 20:11:25,947 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC Ttop Motor M34310. Result: 2025-06-12 20:11:26,665 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:26,667 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:26,668 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > FC > Minimotor > FC Ttop Motor M34310 (FC318) > Block was successfully compiled. Exportando FC Ttop Motor M34310 como XML... 2025-06-12 20:11:26,739 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Motor M34310 exported successfully 2025-06-12 20:11:26,740 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Motor M34310 exported successfully Procesando bloque: DB Ttop Motor M31510... Exportando DB Ttop Motor M31510 como XML... 2025-06-12 20:11:26,771 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31510 exported successfully 2025-06-12 20:11:26,773 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31510 exported successfully Procesando bloque: DB Ttop Motor M31610... Compilando bloque DB Ttop Motor M31610... 2025-06-12 20:11:26,774 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31610. Result: 2025-06-12 20:11:27,460 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:27,460 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:27,460 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31610 (DB302) > Block was successfully compiled. Exportando DB Ttop Motor M31610 como XML... 2025-06-12 20:11:27,497 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31610 exported successfully 2025-06-12 20:11:27,497 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31610 exported successfully Procesando bloque: DB Ttop Motor M31710... Compilando bloque DB Ttop Motor M31710... 2025-06-12 20:11:27,501 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31710. Result: 2025-06-12 20:11:28,057 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:28,059 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:28,059 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31710 (DB303) > Block was successfully compiled. Exportando DB Ttop Motor M31710 como XML... 2025-06-12 20:11:28,112 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31710 exported successfully 2025-06-12 20:11:28,113 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31710 exported successfully Procesando bloque: DB Ttop Motor M31810... Compilando bloque DB Ttop Motor M31810... 2025-06-12 20:11:28,116 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31810. Result: 2025-06-12 20:11:28,727 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:28,727 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:28,728 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31810 (DB304) > Block was successfully compiled. Exportando DB Ttop Motor M31810 como XML... 2025-06-12 20:11:28,772 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31810 exported successfully 2025-06-12 20:11:28,773 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31810 exported successfully Procesando bloque: DB Ttop Motor M31910... Compilando bloque DB Ttop Motor M31910... 2025-06-12 20:11:28,776 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31910. Result: 2025-06-12 20:11:29,366 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:29,366 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:29,367 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31910 (DB305) > Block was successfully compiled. Exportando DB Ttop Motor M31910 como XML... 2025-06-12 20:11:29,391 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31910 exported successfully 2025-06-12 20:11:29,391 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31910 exported successfully Procesando bloque: DB Ttop Motor U32810... Compilando bloque DB Ttop Motor U32810... 2025-06-12 20:11:29,396 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U32810. Result: 2025-06-12 20:11:29,978 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:29,978 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:29,978 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U32810 (DB306) > Block was successfully compiled. Exportando DB Ttop Motor U32810 como XML... 2025-06-12 20:11:30,005 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U32810 exported successfully 2025-06-12 20:11:30,006 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U32810 exported successfully Procesando bloque: DB Ttop Motor U32910... Compilando bloque DB Ttop Motor U32910... 2025-06-12 20:11:30,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U32910. Result: 2025-06-12 20:11:30,556 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:30,557 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:30,557 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U32910 (DB307) > Block was successfully compiled. Exportando DB Ttop Motor U32910 como XML... 2025-06-12 20:11:30,586 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U32910 exported successfully 2025-06-12 20:11:30,588 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U32910 exported successfully Procesando bloque: DB Ttop Motor U33010... Compilando bloque DB Ttop Motor U33010... 2025-06-12 20:11:30,590 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33010. Result: 2025-06-12 20:11:31,158 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:31,158 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:31,158 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33010 (DB308) > Block was successfully compiled. Exportando DB Ttop Motor U33010 como XML... 2025-06-12 20:11:31,185 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33010 exported successfully 2025-06-12 20:11:31,185 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33010 exported successfully Procesando bloque: DB Ttop Motor U33110... Compilando bloque DB Ttop Motor U33110... 2025-06-12 20:11:31,187 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33110. Result: 2025-06-12 20:11:31,754 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:31,755 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:31,755 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33110 (DB309) > Block was successfully compiled. Exportando DB Ttop Motor U33110 como XML... 2025-06-12 20:11:31,782 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33110 exported successfully 2025-06-12 20:11:31,784 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33110 exported successfully Procesando bloque: DB Ttop Motor U33210... Compilando bloque DB Ttop Motor U33210... 2025-06-12 20:11:31,788 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33210. Result: 2025-06-12 20:11:32,387 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:32,388 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:32,388 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33210 (DB310) > Block was successfully compiled. Exportando DB Ttop Motor U33210 como XML... 2025-06-12 20:11:32,418 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33210 exported successfully 2025-06-12 20:11:32,420 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33210 exported successfully Procesando bloque: DB Ttop Motor U33310... Compilando bloque DB Ttop Motor U33310... 2025-06-12 20:11:32,423 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33310. Result: 2025-06-12 20:11:33,010 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:33,011 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:33,011 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33310 (DB311) > Block was successfully compiled. Exportando DB Ttop Motor U33310 como XML... 2025-06-12 20:11:33,038 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33310 exported successfully 2025-06-12 20:11:33,039 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33310 exported successfully Procesando bloque: DB Ttop Motor U33410... Compilando bloque DB Ttop Motor U33410... 2025-06-12 20:11:33,041 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33410. Result: 2025-06-12 20:11:33,605 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:33,605 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:33,605 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33410 (DB312) > Block was successfully compiled. Exportando DB Ttop Motor U33410 como XML... 2025-06-12 20:11:33,631 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33410 exported successfully 2025-06-12 20:11:33,632 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33410 exported successfully Procesando bloque: DB Ttop Motor U33510... Compilando bloque DB Ttop Motor U33510... 2025-06-12 20:11:33,637 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33510. Result: 2025-06-12 20:11:34,210 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:34,211 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:34,211 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33510 (DB313) > Block was successfully compiled. Exportando DB Ttop Motor U33510 como XML... 2025-06-12 20:11:34,238 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33510 exported successfully 2025-06-12 20:11:34,239 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33510 exported successfully Procesando bloque: DB Ttop Motor U33610... Compilando bloque DB Ttop Motor U33610... 2025-06-12 20:11:34,241 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor U33610. Result: 2025-06-12 20:11:34,817 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:34,818 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:34,818 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor U33610 (DB314) > Block was successfully compiled. Exportando DB Ttop Motor U33610 como XML... 2025-06-12 20:11:34,847 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor U33610 exported successfully 2025-06-12 20:11:34,849 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor U33610 exported successfully Procesando bloque: DB Ttop Motor M34010... Compilando bloque DB Ttop Motor M34010... 2025-06-12 20:11:34,854 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M34010. Result: 2025-06-12 20:11:35,450 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:35,450 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:35,451 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M34010 (DB315) > Block was successfully compiled. Exportando DB Ttop Motor M34010 como XML... 2025-06-12 20:11:35,475 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M34010 exported successfully 2025-06-12 20:11:35,476 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M34010 exported successfully Procesando bloque: DB Ttop Motor M34110... Compilando bloque DB Ttop Motor M34110... 2025-06-12 20:11:35,478 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M34110. Result: 2025-06-12 20:11:36,086 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:36,087 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:36,087 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M34110 (DB316) > Block was successfully compiled. Exportando DB Ttop Motor M34110 como XML... 2025-06-12 20:11:36,111 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M34110 exported successfully 2025-06-12 20:11:36,111 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M34110 exported successfully Procesando bloque: DB Ttop Motor M34210... Compilando bloque DB Ttop Motor M34210... 2025-06-12 20:11:36,113 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M34210. Result: 2025-06-12 20:11:36,692 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:36,692 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:36,693 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M34210 (DB317) > Block was successfully compiled. Exportando DB Ttop Motor M34210 como XML... 2025-06-12 20:11:36,721 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M34210 exported successfully 2025-06-12 20:11:36,722 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M34210 exported successfully Procesando bloque: DB Ttop Motor M34310... Compilando bloque DB Ttop Motor M34310... 2025-06-12 20:11:36,724 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M34310. Result: 2025-06-12 20:11:37,326 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:37,326 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:37,326 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M34310 (DB318) > Block was successfully compiled. Exportando DB Ttop Motor M34310 como XML... 2025-06-12 20:11:37,369 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M34310 exported successfully 2025-06-12 20:11:37,370 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M34310 exported successfully Procesando bloque: DB Ttop Motor M30710... Compilando bloque DB Ttop Motor M30710... 2025-06-12 20:11:37,372 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M30710. Result: 2025-06-12 20:11:37,943 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:37,943 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:37,944 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M30710 (DB326) > Block was successfully compiled. Exportando DB Ttop Motor M30710 como XML... 2025-06-12 20:11:37,976 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M30710 exported successfully 2025-06-12 20:11:37,977 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M30710 exported successfully Procesando bloque: DB Ttop Motor M31010... Compilando bloque DB Ttop Motor M31010... 2025-06-12 20:11:37,982 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31010. Result: 2025-06-12 20:11:38,607 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:38,607 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:38,607 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31010 (DB327) > Block was successfully compiled. Exportando DB Ttop Motor M31010 como XML... 2025-06-12 20:11:38,633 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31010 exported successfully 2025-06-12 20:11:38,635 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31010 exported successfully Procesando bloque: DB Ttop Motor M31110... Compilando bloque DB Ttop Motor M31110... 2025-06-12 20:11:38,637 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31110. Result: 2025-06-12 20:11:39,225 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:39,225 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:39,226 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31110 (DB328) > Block was successfully compiled. Exportando DB Ttop Motor M31110 como XML... 2025-06-12 20:11:39,253 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31110 exported successfully 2025-06-12 20:11:39,254 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31110 exported successfully Procesando bloque: DB Ttop Motor M31210... Compilando bloque DB Ttop Motor M31210... 2025-06-12 20:11:39,256 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31210. Result: 2025-06-12 20:11:39,849 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:39,850 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:39,850 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31210 (DB329) > Block was successfully compiled. Exportando DB Ttop Motor M31210 como XML... 2025-06-12 20:11:39,882 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31210 exported successfully 2025-06-12 20:11:39,883 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31210 exported successfully Procesando bloque: DB Ttop Motor M31310... Compilando bloque DB Ttop Motor M31310... 2025-06-12 20:11:39,887 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31310. Result: 2025-06-12 20:11:40,468 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:40,469 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:40,469 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31310 (DB330) > Block was successfully compiled. Exportando DB Ttop Motor M31310 como XML... 2025-06-12 20:11:40,501 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31310 exported successfully 2025-06-12 20:11:40,502 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31310 exported successfully Procesando bloque: DB Ttop Motor M34410... Compilando bloque DB Ttop Motor M34410... 2025-06-12 20:11:40,504 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M34410. Result: 2025-06-12 20:11:41,079 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:41,080 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:41,080 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M34410 (DB319) > Block was successfully compiled. Exportando DB Ttop Motor M34410 como XML... 2025-06-12 20:11:41,113 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M34410 exported successfully 2025-06-12 20:11:41,114 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M34410 exported successfully Procesando bloque: DB Ttop Motor M31410... Compilando bloque DB Ttop Motor M31410... 2025-06-12 20:11:41,118 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Motor M31410. Result: 2025-06-12 20:11:41,683 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:41,684 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:41,685 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > DB Ttop Motor M31410 (DB331) > Block was successfully compiled. Exportando DB Ttop Motor M31410 como XML... 2025-06-12 20:11:41,707 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Motor M31410 exported successfully 2025-06-12 20:11:41,708 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Motor M31410 exported successfully Procesando bloque: DB Ttop Minimotor Data M31610... Compilando bloque DB Ttop Minimotor Data M31610... 2025-06-12 20:11:41,711 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31610. Result: 2025-06-12 20:11:42,312 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:42,312 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) Exportando DB Ttop Minimotor Data M31610 como XML... 2025-06-12 20:11:42,357 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31610 exported successfully 2025-06-12 20:11:42,358 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31610 exported successfully Procesando bloque: DB Ttop Minimotor Data M31710... Compilando bloque DB Ttop Minimotor Data M31710... 2025-06-12 20:11:42,360 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31710. Result: 2025-06-12 20:11:42,939 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:42,940 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:42,940 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M31710 (DB803) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M31710 como XML... 2025-06-12 20:11:42,971 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31710 exported successfully 2025-06-12 20:11:42,972 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31710 exported successfully Procesando bloque: DB Ttop Minimotor Data M31810... Compilando bloque DB Ttop Minimotor Data M31810... 2025-06-12 20:11:42,974 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31810. Result: 2025-06-12 20:11:43,573 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:43,574 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:43,574 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M31810 (DB804) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M31810 como XML... 2025-06-12 20:11:43,617 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31810 exported successfully 2025-06-12 20:11:43,618 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31810 exported successfully Procesando bloque: DB Ttop Minimotor Data M31910... Compilando bloque DB Ttop Minimotor Data M31910... 2025-06-12 20:11:43,620 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31910. Result: 2025-06-12 20:11:44,197 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:44,198 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:44,198 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M31910 (DB805) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M31910 como XML... 2025-06-12 20:11:44,225 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31910 exported successfully 2025-06-12 20:11:44,225 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31910 exported successfully Procesando bloque: DB Ttop Minimotor Data M34010... Compilando bloque DB Ttop Minimotor Data M34010... 2025-06-12 20:11:44,227 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M34010. Result: 2025-06-12 20:11:44,828 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:44,829 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:44,829 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M34010 (DB806) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M34010 como XML... 2025-06-12 20:11:44,861 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M34010 exported successfully 2025-06-12 20:11:44,862 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M34010 exported successfully Procesando bloque: DB Ttop Minimotor Data M34110... Compilando bloque DB Ttop Minimotor Data M34110... 2025-06-12 20:11:44,864 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M34110. Result: 2025-06-12 20:11:45,445 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:45,445 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:45,446 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M34110 (DB807) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M34110 como XML... 2025-06-12 20:11:45,471 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M34110 exported successfully 2025-06-12 20:11:45,472 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M34110 exported successfully Procesando bloque: DB Ttop Minimotor Data M34210... Compilando bloque DB Ttop Minimotor Data M34210... 2025-06-12 20:11:45,473 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M34210. Result: 2025-06-12 20:11:46,258 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:46,258 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:46,258 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M34210 (DB808) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M34210 como XML... 2025-06-12 20:11:46,297 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M34210 exported successfully 2025-06-12 20:11:46,298 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M34210 exported successfully Procesando bloque: DB Ttop Minimotor Data M34310... Compilando bloque DB Ttop Minimotor Data M34310... 2025-06-12 20:11:46,303 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M34310. Result: 2025-06-12 20:11:46,996 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:46,996 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:46,997 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M34310 (DB809) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M34310 como XML... 2025-06-12 20:11:47,047 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M34310 exported successfully 2025-06-12 20:11:47,053 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M34310 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M30710... Compilando bloque DB Ttop Minimotor Cfg M30710... 2025-06-12 20:11:47,056 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M30710. Result: 2025-06-12 20:11:47,681 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:47,681 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:47,682 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M30710 (DB710) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M30710 como XML... 2025-06-12 20:11:47,728 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M30710 exported successfully 2025-06-12 20:11:47,729 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M30710 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31110... Compilando bloque DB Ttop Minimotor Cfg M31110... 2025-06-12 20:11:47,735 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31110. Result: 2025-06-12 20:11:48,451 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:48,452 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:48,452 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M31110 (DB711) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M31110 como XML... 2025-06-12 20:11:48,486 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31110 exported successfully 2025-06-12 20:11:48,486 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31110 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31210... Compilando bloque DB Ttop Minimotor Cfg M31210... 2025-06-12 20:11:48,489 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31210. Result: 2025-06-12 20:11:49,205 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:49,206 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:49,206 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M31210 (DB712) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M31210 como XML... 2025-06-12 20:11:49,236 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31210 exported successfully 2025-06-12 20:11:49,237 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31210 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31310... Compilando bloque DB Ttop Minimotor Cfg M31310... 2025-06-12 20:11:49,241 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31310. Result: 2025-06-12 20:11:50,151 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:50,152 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:50,152 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M31310 (DB713) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M31310 como XML... 2025-06-12 20:11:50,205 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31310 exported successfully 2025-06-12 20:11:50,206 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31310 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31610... Compilando bloque DB Ttop Minimotor Cfg M31610... 2025-06-12 20:11:50,213 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31610. Result: 2025-06-12 20:11:50,780 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:50,780 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) Exportando DB Ttop Minimotor Cfg M31610 como XML... 2025-06-12 20:11:50,809 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31610 exported successfully 2025-06-12 20:11:50,809 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31610 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31710... Compilando bloque DB Ttop Minimotor Cfg M31710... 2025-06-12 20:11:50,811 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31710. Result: 2025-06-12 20:11:51,444 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:51,445 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:51,445 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M31710 (DB703) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M31710 como XML... 2025-06-12 20:11:51,471 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31710 exported successfully 2025-06-12 20:11:51,472 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31710 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31810... Compilando bloque DB Ttop Minimotor Cfg M31810... 2025-06-12 20:11:51,473 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31810. Result: 2025-06-12 20:11:51,992 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:51,993 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:51,993 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M31810 (DB704) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M31810 como XML... 2025-06-12 20:11:52,017 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31810 exported successfully 2025-06-12 20:11:52,018 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31810 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M31910... Compilando bloque DB Ttop Minimotor Cfg M31910... 2025-06-12 20:11:52,020 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M31910. Result: 2025-06-12 20:11:52,545 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:52,546 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:52,546 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M31910 (DB705) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M31910 como XML... 2025-06-12 20:11:52,575 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M31910 exported successfully 2025-06-12 20:11:52,576 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M31910 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M34010... Compilando bloque DB Ttop Minimotor Cfg M34010... 2025-06-12 20:11:52,581 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M34010. Result: 2025-06-12 20:11:53,276 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:53,276 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:53,277 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M34010 (DB706) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M34010 como XML... 2025-06-12 20:11:53,302 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M34010 exported successfully 2025-06-12 20:11:53,303 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M34010 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M34110... Compilando bloque DB Ttop Minimotor Cfg M34110... 2025-06-12 20:11:53,306 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M34110. Result: 2025-06-12 20:11:53,932 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:53,933 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:53,933 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M34110 (DB707) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M34110 como XML... 2025-06-12 20:11:53,957 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M34110 exported successfully 2025-06-12 20:11:53,958 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M34110 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M34210... Compilando bloque DB Ttop Minimotor Cfg M34210... 2025-06-12 20:11:53,960 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M34210. Result: 2025-06-12 20:11:54,682 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:54,683 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:54,684 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M34210 (DB708) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M34210 como XML... 2025-06-12 20:11:54,729 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M34210 exported successfully 2025-06-12 20:11:54,729 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M34210 exported successfully Procesando bloque: DB Ttop Minimotor Cfg M34310... Compilando bloque DB Ttop Minimotor Cfg M34310... 2025-06-12 20:11:54,731 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Cfg M34310. Result: 2025-06-12 20:11:55,337 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:55,339 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:55,339 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Cfg M34310 (DB709) > Block was successfully compiled. Exportando DB Ttop Minimotor Cfg M34310 como XML... 2025-06-12 20:11:55,362 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Cfg M34310 exported successfully 2025-06-12 20:11:55,363 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Cfg M34310 exported successfully Procesando bloque: DB Ttop Minimotor Data M30710... Compilando bloque DB Ttop Minimotor Data M30710... 2025-06-12 20:11:55,368 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M30710. Result: 2025-06-12 20:11:56,020 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:56,021 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:56,021 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M30710 (DB810) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M30710 como XML... 2025-06-12 20:11:56,056 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M30710 exported successfully 2025-06-12 20:11:56,057 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M30710 exported successfully Procesando bloque: DB Ttop Minimotor Data M31110... Compilando bloque DB Ttop Minimotor Data M31110... 2025-06-12 20:11:56,059 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31110. Result: 2025-06-12 20:11:56,643 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:56,643 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:56,643 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M31110 (DB811) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M31110 como XML... 2025-06-12 20:11:56,688 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31110 exported successfully 2025-06-12 20:11:56,688 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31110 exported successfully Procesando bloque: DB Ttop Minimotor Data M31210... Compilando bloque DB Ttop Minimotor Data M31210... 2025-06-12 20:11:56,690 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31210. Result: 2025-06-12 20:11:57,308 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:57,309 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:57,309 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M31210 (DB812) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M31210 como XML... 2025-06-12 20:11:57,334 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31210 exported successfully 2025-06-12 20:11:57,335 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31210 exported successfully Procesando bloque: DB Ttop Minimotor Data M31310... Compilando bloque DB Ttop Minimotor Data M31310... 2025-06-12 20:11:57,338 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block DB Ttop Minimotor Data M31310. Result: 2025-06-12 20:11:57,908 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:11:57,908 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:11:57,908 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 1 - CONVEYORS > 2 - TTOP > Motor > DB > Minimotor > DB Ttop Minimotor Data M31310 (DB813) > Block was successfully compiled. Exportando DB Ttop Minimotor Data M31310 como XML... 2025-06-12 20:11:57,932 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Minimotor Data M31310 exported successfully 2025-06-12 20:11:57,933 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Minimotor Data M31310 exported successfully Procesando bloque: FB Ttop Energy Saving... Exportando FB Ttop Energy Saving como XML... 2025-06-12 20:11:57,972 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Ttop Energy Saving exported successfully 2025-06-12 20:11:57,973 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Ttop Energy Saving exported successfully Procesando bloque: FC Simple PID... Exportando FC Simple PID como XML... 2025-06-12 20:11:58,218 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Simple PID exported successfully 2025-06-12 20:11:58,220 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Simple PID exported successfully Procesando bloque: FC Scale Real... Exportando FC Scale Real como XML... 2025-06-12 20:11:58,295 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Scale Real exported successfully 2025-06-12 20:11:58,296 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Scale Real exported successfully Procesando bloque: FB Master Slave PID... Exportando FB Master Slave PID como XML... 2025-06-12 20:11:58,373 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Master Slave PID exported successfully 2025-06-12 20:11:58,373 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Master Slave PID exported successfully Procesando bloque: FC Scale Speed w/Gap... Exportando FC Scale Speed w/Gap como XML... 2025-06-12 20:11:58,404 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Scale Speed w/Gap exported successfully 2025-06-12 20:11:58,405 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Scale Speed w/Gap exported successfully Procesando bloque: FC S_Everz_ON_OFF... Exportando FC S_Everz_ON_OFF como XML... 2025-06-12 20:11:58,448 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC S_Everz_ON_OFF exported successfully 2025-06-12 20:11:58,452 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC S_Everz_ON_OFF exported successfully Procesando bloque: FB_BottleFallen... Exportando FB_BottleFallen como XML... 2025-06-12 20:11:58,542 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB_BottleFallen exported successfully 2025-06-12 20:11:58,543 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB_BottleFallen exported successfully Procesando bloque: Calculate Elapsed Time... Exportando Calculate Elapsed Time como XML... 2025-06-12 20:11:58,590 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: Calculate Elapsed Time exported successfully 2025-06-12 20:11:58,591 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - Calculate Elapsed Time exported successfully Procesando bloque: FB Calculate Ramp... Exportando FB Calculate Ramp como XML... 2025-06-12 20:11:58,627 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Calculate Ramp exported successfully 2025-06-12 20:11:58,627 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Calculate Ramp exported successfully Procesando bloque: FB Calculate Ramp UpDown... Exportando FB Calculate Ramp UpDown como XML... 2025-06-12 20:11:58,663 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Calculate Ramp UpDown exported successfully 2025-06-12 20:11:58,664 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Calculate Ramp UpDown exported successfully Procesando bloque: FB FIFO Manage DataType Real... Exportando FB FIFO Manage DataType Real como XML... 2025-06-12 20:11:58,694 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB FIFO Manage DataType Real exported successfully 2025-06-12 20:11:58,695 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB FIFO Manage DataType Real exported successfully Procesando bloque: FB Show Alarms... Exportando FB Show Alarms como XML... 2025-06-12 20:11:58,730 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Show Alarms exported successfully 2025-06-12 20:11:58,731 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Show Alarms exported successfully Procesando bloque: FC Ttop Devices... Exportando FC Ttop Devices como XML... 2025-06-12 20:11:58,777 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Devices exported successfully 2025-06-12 20:11:58,778 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Devices exported successfully Procesando bloque: DB Ttop Energy Saving Z1... Exportando DB Ttop Energy Saving Z1 como XML... 2025-06-12 20:11:58,806 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Energy Saving Z1 exported successfully 2025-06-12 20:11:58,807 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Energy Saving Z1 exported successfully Procesando bloque: DB Ttop Fifo 1... Exportando DB Ttop Fifo 1 como XML... 2025-06-12 20:11:58,833 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Fifo 1 exported successfully 2025-06-12 20:11:58,835 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Fifo 1 exported successfully Procesando bloque: DB Ttop Fifo 2... Exportando DB Ttop Fifo 2 como XML... 2025-06-12 20:11:58,860 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Fifo 2 exported successfully 2025-06-12 20:11:58,861 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Fifo 2 exported successfully Procesando bloque: DB Ttop Energy Saving Z2... Exportando DB Ttop Energy Saving Z2 como XML... 2025-06-12 20:11:58,888 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Energy Saving Z2 exported successfully 2025-06-12 20:11:58,889 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Energy Saving Z2 exported successfully Procesando bloque: DB Ttop Energy Saving Z3... Exportando DB Ttop Energy Saving Z3 como XML... 2025-06-12 20:11:58,913 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Ttop Energy Saving Z3 exported successfully 2025-06-12 20:11:58,913 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Ttop Energy Saving Z3 exported successfully Procesando bloque: DB SICK_AFx60_PN_M34... Exportando DB SICK_AFx60_PN_M34 como XML... 2025-06-12 20:11:58,943 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB SICK_AFx60_PN_M34 exported successfully 2025-06-12 20:11:58,944 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB SICK_AFx60_PN_M34 exported successfully Procesando bloque: DB_SICK_AFx60_Data... Exportando DB_SICK_AFx60_Data como XML... 2025-06-12 20:11:58,976 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB_SICK_AFx60_Data exported successfully 2025-06-12 20:11:58,977 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB_SICK_AFx60_Data exported successfully Procesando bloque: DB General... Exportando DB General como XML... 2025-06-12 20:11:59,058 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB General exported successfully 2025-06-12 20:11:59,059 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB General exported successfully Procesando bloque: DB General Alarms... Exportando DB General Alarms como XML... 2025-06-12 20:11:59,105 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB General Alarms exported successfully 2025-06-12 20:11:59,106 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB General Alarms exported successfully Procesando bloque: DB Warnings... Exportando DB Warnings como XML... 2025-06-12 20:11:59,135 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Warnings exported successfully 2025-06-12 20:11:59,150 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Warnings exported successfully Procesando bloque: DB Flow Selection... Exportando DB Flow Selection como XML... 2025-06-12 20:11:59,177 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Flow Selection exported successfully 2025-06-12 20:11:59,178 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Flow Selection exported successfully Procesando bloque: FC General Alarms... Compilando bloque FC General Alarms... 2025-06-12 20:11:59,187 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block FC General Alarms. Result: 2025-06-12 20:12:00,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 0 - MAIN > FC > FC General Alarms (FC171) > Network 1 > The address is not occupied by a tag. 2025-06-12 20:12:00,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 0 - MAIN > FC > FC General Alarms (FC171) > Network 5 > The address is not occupied by a tag. 2025-06-12 20:12:00,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Program blocks > 0 - MAIN > FC > FC General Alarms (FC171) > Network 11 > The address is not occupied by a tag. 2025-06-12 20:12:00,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:12:00,138 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 44) 2025-06-12 20:12:00,138 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > 0 - MAIN > FC > FC General Alarms (FC171) > Block was successfully compiled. Exportando FC General Alarms como XML... 2025-06-12 20:12:00,201 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC General Alarms exported successfully 2025-06-12 20:12:00,202 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC General Alarms exported successfully Procesando bloque: FC General Warning... Exportando FC General Warning como XML... 2025-06-12 20:12:00,236 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC General Warning exported successfully 2025-06-12 20:12:00,237 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC General Warning exported successfully Procesando bloque: FC General Lamp... Exportando FC General Lamp como XML... 2025-06-12 20:12:00,275 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC General Lamp exported successfully 2025-06-12 20:12:00,276 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC General Lamp exported successfully Procesando bloque: CYCL_EXC... Exportando CYCL_EXC como XML... 2025-06-12 20:12:00,336 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: CYCL_EXC exported successfully 2025-06-12 20:12:00,337 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - CYCL_EXC exported successfully Procesando bloque: CYCL_FLT... Exportando CYCL_FLT como XML... 2025-06-12 20:12:00,369 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: CYCL_FLT exported successfully 2025-06-12 20:12:00,370 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - CYCL_FLT exported successfully Procesando bloque: HW_ERR... Exportando HW_ERR como XML... 2025-06-12 20:12:00,392 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: HW_ERR exported successfully 2025-06-12 20:12:00,392 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - HW_ERR exported successfully Procesando bloque: HW_INT0... Exportando HW_INT0 como XML... 2025-06-12 20:12:00,414 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: HW_INT0 exported successfully 2025-06-12 20:12:00,415 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - HW_INT0 exported successfully Procesando bloque: I/O_FLT1... Exportando I/O_FLT1 como XML... 2025-06-12 20:12:00,439 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: I/O_FLT1 exported successfully 2025-06-12 20:12:00,440 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - I/O_FLT1 exported successfully Procesando bloque: I/O_FLT2... Exportando I/O_FLT2 como XML... 2025-06-12 20:12:00,463 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: I/O_FLT2 exported successfully 2025-06-12 20:12:00,464 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - I/O_FLT2 exported successfully Procesando bloque: PROG_ERR... Exportando PROG_ERR como XML... 2025-06-12 20:12:00,490 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: PROG_ERR exported successfully 2025-06-12 20:12:00,491 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PROG_ERR exported successfully Procesando bloque: RACK_FLT... Exportando RACK_FLT como XML... 2025-06-12 20:12:00,512 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: RACK_FLT exported successfully 2025-06-12 20:12:00,513 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - RACK_FLT exported successfully Procesando bloque: RESTART... Exportando RESTART como XML... 2025-06-12 20:12:00,542 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: RESTART exported successfully 2025-06-12 20:12:00,543 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - RESTART exported successfully Procesando bloque: Startup STOP to RUN... Exportando Startup STOP to RUN como XML... 2025-06-12 20:12:00,570 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: Startup STOP to RUN exported successfully 2025-06-12 20:12:00,571 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - Startup STOP to RUN exported successfully Procesando bloque: DB BottleFallen... Exportando DB BottleFallen como XML... 2025-06-12 20:12:00,596 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB BottleFallen exported successfully 2025-06-12 20:12:00,596 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB BottleFallen exported successfully Procesando bloque: DB Elapsed Time... Exportando DB Elapsed Time como XML... 2025-06-12 20:12:00,621 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Elapsed Time exported successfully 2025-06-12 20:12:00,622 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Elapsed Time exported successfully Procesando bloque: COPIA DBW... Exportando COPIA DBW como XML... 2025-06-12 20:12:00,758 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: COPIA DBW exported successfully 2025-06-12 20:12:00,759 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - COPIA DBW exported successfully Procesando bloque: FC CTR Alarm... Exportando FC CTR Alarm como XML... 2025-06-12 20:12:00,835 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC CTR Alarm exported successfully 2025-06-12 20:12:00,835 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC CTR Alarm exported successfully Procesando bloque: FC Mot Init CFG... Exportando FC Mot Init CFG como XML... 2025-06-12 20:12:00,894 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Init CFG exported successfully 2025-06-12 20:12:00,895 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Init CFG exported successfully Procesando bloque: FC Read EOLO mBar... Exportando FC Read EOLO mBar como XML... 2025-06-12 20:12:00,941 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Read EOLO mBar exported successfully 2025-06-12 20:12:00,942 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Read EOLO mBar exported successfully Procesando bloque: FC Reference management... Exportando FC Reference management como XML... 2025-06-12 20:12:00,993 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Reference management exported successfully 2025-06-12 20:12:00,993 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Reference management exported successfully Procesando bloque: FC S_Everz... Exportando FC S_Everz como XML... 2025-06-12 20:12:01,028 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC S_Everz exported successfully 2025-06-12 20:12:01,029 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC S_Everz exported successfully Procesando bloque: FC Scaling... Exportando FC Scaling como XML... 2025-06-12 20:12:01,056 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Scaling exported successfully 2025-06-12 20:12:01,057 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Scaling exported successfully Procesando bloque: Fill Zero Area... Exportando Fill Zero Area como XML... 2025-06-12 20:12:01,101 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: Fill Zero Area exported successfully 2025-06-12 20:12:01,102 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - Fill Zero Area exported successfully Procesando bloque: FC Turk Lamp... Exportando FC Turk Lamp como XML... 2025-06-12 20:12:01,153 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Turk Lamp exported successfully 2025-06-12 20:12:01,156 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Turk Lamp exported successfully Procesando bloque: FC CMP Machine... Exportando FC CMP Machine como XML... 2025-06-12 20:12:01,191 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC CMP Machine exported successfully 2025-06-12 20:12:01,191 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC CMP Machine exported successfully Procesando bloque: FC CFG TTOP MultiRow 2/1... Exportando FC CFG TTOP MultiRow 2/1 como XML... 2025-06-12 20:12:01,220 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC CFG TTOP MultiRow 2/1 exported successfully 2025-06-12 20:12:01,221 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC CFG TTOP MultiRow 2/1 exported successfully Procesando bloque: FC CFG TTOP MultiRow 3/2... Exportando FC CFG TTOP MultiRow 3/2 como XML... 2025-06-12 20:12:01,253 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC CFG TTOP MultiRow 3/2 exported successfully 2025-06-12 20:12:01,255 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC CFG TTOP MultiRow 3/2 exported successfully Procesando bloque: FC Compute AN Speed... Exportando FC Compute AN Speed como XML... 2025-06-12 20:12:01,293 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Compute AN Speed exported successfully 2025-06-12 20:12:01,294 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Compute AN Speed exported successfully Procesando bloque: FC Profinet_Allarms... Exportando FC Profinet_Allarms como XML... 2025-06-12 20:12:01,342 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Profinet_Allarms exported successfully 2025-06-12 20:12:01,343 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Profinet_Allarms exported successfully Procesando bloque: FC S_Everz_Struct... Exportando FC S_Everz_Struct como XML... 2025-06-12 20:12:01,397 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC S_Everz_Struct exported successfully 2025-06-12 20:12:01,398 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC S_Everz_Struct exported successfully Procesando bloque: FC Read DI... Exportando FC Read DI como XML... 2025-06-12 20:12:01,457 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Read DI exported successfully 2025-06-12 20:12:01,458 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Read DI exported successfully Exportando FC Read DI como SCL... 2025-06-12 20:12:02,556 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC Read DI external source successfully generated Procesando bloque: FC Read DO... Exportando FC Read DO como XML... 2025-06-12 20:12:02,603 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Read DO exported successfully 2025-06-12 20:12:02,604 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Read DO exported successfully Exportando FC Read DO como SCL... 2025-06-12 20:12:02,638 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC Read DO external source successfully generated Procesando bloque: FC Write DO... Exportando FC Write DO como XML... 2025-06-12 20:12:02,677 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Write DO exported successfully 2025-06-12 20:12:02,678 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Write DO exported successfully Exportando FC Write DO como SCL... 2025-06-12 20:12:02,718 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC Write DO external source successfully generated Procesando bloque: COPIA DBs... Exportando COPIA DBs como XML... 2025-06-12 20:12:02,759 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: COPIA DBs exported successfully 2025-06-12 20:12:02,760 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - COPIA DBs exported successfully Procesando bloque: FC Get DBnum... Exportando FC Get DBnum como XML... 2025-06-12 20:12:02,824 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Get DBnum exported successfully 2025-06-12 20:12:02,825 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Get DBnum exported successfully Procesando bloque: FC Compute Machine Speed... Exportando FC Compute Machine Speed como XML... 2025-06-12 20:12:02,963 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Compute Machine Speed exported successfully 2025-06-12 20:12:02,964 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Compute Machine Speed exported successfully Procesando bloque: FC Signal Configuration Bits... Exportando FC Signal Configuration Bits como XML... 2025-06-12 20:12:03,040 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signal Configuration Bits exported successfully 2025-06-12 20:12:03,041 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signal Configuration Bits exported successfully Procesando bloque: FC Signal Discharge Output Force... Exportando FC Signal Discharge Output Force como XML... 2025-06-12 20:12:03,086 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signal Discharge Output Force exported successfully 2025-06-12 20:12:03,087 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signal Discharge Output Force exported successfully Procesando bloque: FC Signal Infeed Output Force... Exportando FC Signal Infeed Output Force como XML... 2025-06-12 20:12:03,111 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signal Infeed Output Force exported successfully 2025-06-12 20:12:03,111 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signal Infeed Output Force exported successfully Procesando bloque: FC Signal Input Force Control... Exportando FC Signal Input Force Control como XML... 2025-06-12 20:12:03,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signal Input Force Control exported successfully 2025-06-12 20:12:03,138 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signal Input Force Control exported successfully Procesando bloque: FC Signals Discharge Timers... Exportando FC Signals Discharge Timers como XML... 2025-06-12 20:12:03,174 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signals Discharge Timers exported successfully 2025-06-12 20:12:03,174 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signals Discharge Timers exported successfully Procesando bloque: FC Signals Discharge Timers Read... Exportando FC Signals Discharge Timers Read como XML... 2025-06-12 20:12:03,214 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signals Discharge Timers Read exported successfully 2025-06-12 20:12:03,216 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signals Discharge Timers Read exported successfully Procesando bloque: FC Signals Infeed Timers... Exportando FC Signals Infeed Timers como XML... 2025-06-12 20:12:03,258 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signals Infeed Timers exported successfully 2025-06-12 20:12:03,274 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signals Infeed Timers exported successfully Procesando bloque: FC Signals Infeed Timers Read... Exportando FC Signals Infeed Timers Read como XML... 2025-06-12 20:12:03,305 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Signals Infeed Timers Read exported successfully 2025-06-12 20:12:03,305 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Signals Infeed Timers Read exported successfully Procesando bloque: FB Run Timer Selector... Exportando FB Run Timer Selector como XML... 2025-06-12 20:12:03,349 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Run Timer Selector exported successfully 2025-06-12 20:12:03,351 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Run Timer Selector exported successfully Procesando bloque: DB Run Signal Selector... Exportando DB Run Signal Selector como XML... 2025-06-12 20:12:03,380 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Run Signal Selector exported successfully 2025-06-12 20:12:03,380 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Run Signal Selector exported successfully Procesando bloque: FC HMI... Exportando FC HMI como XML... 2025-06-12 20:12:03,437 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC HMI exported successfully 2025-06-12 20:12:03,438 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC HMI exported successfully Procesando bloque: FC HMI Timer... Exportando FC HMI Timer como XML... 2025-06-12 20:12:03,480 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC HMI Timer exported successfully 2025-06-12 20:12:03,481 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC HMI Timer exported successfully Procesando bloque: FC HMI Date Time... Exportando FC HMI Date Time como XML... 2025-06-12 20:12:03,585 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC HMI Date Time exported successfully 2025-06-12 20:12:03,586 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC HMI Date Time exported successfully Procesando bloque: FC HMI PSW Cfg... Exportando FC HMI PSW Cfg como XML... 2025-06-12 20:12:03,643 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC HMI PSW Cfg exported successfully 2025-06-12 20:12:03,644 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC HMI PSW Cfg exported successfully Procesando bloque: FC HMI Recipe TTop... Exportando FC HMI Recipe TTop como XML... 2025-06-12 20:12:03,687 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC HMI Recipe TTop exported successfully 2025-06-12 20:12:03,688 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC HMI Recipe TTop exported successfully Procesando bloque: FC Mot Manage Movigear... Exportando FC Mot Manage Movigear como XML... 2025-06-12 20:12:03,735 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage Movigear exported successfully 2025-06-12 20:12:03,736 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage Movigear exported successfully Procesando bloque: FC Mot Manage Movimot... Exportando FC Mot Manage Movimot como XML... 2025-06-12 20:12:03,786 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage Movimot exported successfully 2025-06-12 20:12:03,787 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage Movimot exported successfully Procesando bloque: FC Movifit Status... Exportando FC Movifit Status como XML... 2025-06-12 20:12:03,818 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Movifit Status exported successfully 2025-06-12 20:12:03,819 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Movifit Status exported successfully Procesando bloque: FC Mot Manage Bosch Rexroth... Exportando FC Mot Manage Bosch Rexroth como XML... 2025-06-12 20:12:03,861 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage Bosch Rexroth exported successfully 2025-06-12 20:12:03,862 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage Bosch Rexroth exported successfully Procesando bloque: FC Mot Manage Movigear ADV... Exportando FC Mot Manage Movigear ADV como XML... 2025-06-12 20:12:03,915 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage Movigear ADV exported successfully 2025-06-12 20:12:03,916 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage Movigear ADV exported successfully Procesando bloque: FC Mot Manage VFD Analog... Exportando FC Mot Manage VFD Analog como XML... 2025-06-12 20:12:03,950 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage VFD Analog exported successfully 2025-06-12 20:12:03,952 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage VFD Analog exported successfully Procesando bloque: FC Mot Manage VFD/Dig... Exportando FC Mot Manage VFD/Dig como XML... 2025-06-12 20:12:03,990 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage VFD/Dig exported successfully 2025-06-12 20:12:03,991 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage VFD/Dig exported successfully Procesando bloque: FC Siemens G120C... Exportando FC Siemens G120C como XML... 2025-06-12 20:12:04,057 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Siemens G120C exported successfully 2025-06-12 20:12:04,058 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Siemens G120C exported successfully Procesando bloque: FC Mot Manage VFD FC300... Exportando FC Mot Manage VFD FC300 como XML... 2025-06-12 20:12:04,104 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage VFD FC300 exported successfully 2025-06-12 20:12:04,119 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage VFD FC300 exported successfully Procesando bloque: FC Mot Manage Movigear ADV_DPRDAT... Exportando FC Mot Manage Movigear ADV_DPRDAT como XML... 2025-06-12 20:12:04,188 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage Movigear ADV_DPRDAT exported successfully 2025-06-12 20:12:04,189 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage Movigear ADV_DPRDAT exported successfully Procesando bloque: FC Mot Manage VFD FC300_DPRDAT... Exportando FC Mot Manage VFD FC300_DPRDAT como XML... 2025-06-12 20:12:04,242 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage VFD FC300_DPRDAT exported successfully 2025-06-12 20:12:04,243 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage VFD FC300_DPRDAT exported successfully Procesando bloque: FC Mot Manage EOLO mBar... Exportando FC Mot Manage EOLO mBar como XML... 2025-06-12 20:12:04,290 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage EOLO mBar exported successfully 2025-06-12 20:12:04,291 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage EOLO mBar exported successfully Procesando bloque: FC Mot Manage Minimotor... Exportando FC Mot Manage Minimotor como XML... 2025-06-12 20:12:04,359 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Mot Manage Minimotor exported successfully 2025-06-12 20:12:04,361 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Mot Manage Minimotor exported successfully Procesando bloque: FC Motor Protocols... Exportando FC Motor Protocols como XML... 2025-06-12 20:12:04,416 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Motor Protocols exported successfully 2025-06-12 20:12:04,418 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Motor Protocols exported successfully Procesando bloque: FC Simulation... Exportando FC Simulation como XML... 2025-06-12 20:12:04,480 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Simulation exported successfully 2025-06-12 20:12:04,481 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Simulation exported successfully Procesando bloque: DB MotorSimulate... Exportando DB MotorSimulate como XML... 2025-06-12 20:12:04,505 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB MotorSimulate exported successfully 2025-06-12 20:12:04,506 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB MotorSimulate exported successfully Procesando bloque: FC Minimotor Managment... Exportando FC Minimotor Managment como XML... 2025-06-12 20:12:04,530 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Minimotor Managment exported successfully 2025-06-12 20:12:04,531 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Minimotor Managment exported successfully Procesando bloque: FB_Minimotor_Config... Exportando FB_Minimotor_Config como XML... 2025-06-12 20:12:04,670 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB_Minimotor_Config exported successfully 2025-06-12 20:12:04,671 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB_Minimotor_Config exported successfully Procesando bloque: FC_Homing... Exportando FC_Homing como XML... 2025-06-12 20:12:04,735 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC_Homing exported successfully 2025-06-12 20:12:04,736 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC_Homing exported successfully Exportando FC_Homing como SCL... 2025-06-12 20:12:04,799 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC_Homing external source successfully generated Procesando bloque: FC_ProfPos... Exportando FC_ProfPos como XML... 2025-06-12 20:12:04,872 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC_ProfPos exported successfully 2025-06-12 20:12:04,888 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC_ProfPos exported successfully Exportando FC_ProfPos como SCL... 2025-06-12 20:12:04,940 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC_ProfPos external source successfully generated Procesando bloque: FC_ProfTrq... Exportando FC_ProfTrq como XML... 2025-06-12 20:12:04,997 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC_ProfTrq exported successfully 2025-06-12 20:12:04,998 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC_ProfTrq exported successfully Exportando FC_ProfTrq como SCL... 2025-06-12 20:12:05,058 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC_ProfTrq external source successfully generated Procesando bloque: FC_ProfVel... Exportando FC_ProfVel como XML... 2025-06-12 20:12:05,139 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC_ProfVel exported successfully 2025-06-12 20:12:05,153 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC_ProfVel exported successfully Exportando FC_ProfVel como SCL... 2025-06-12 20:12:05,217 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FC_ProfVel external source successfully generated Procesando bloque: FB_MiniMotor_PN... Exportando FB_MiniMotor_PN como XML... 2025-06-12 20:12:05,343 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB_MiniMotor_PN exported successfully 2025-06-12 20:12:05,344 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB_MiniMotor_PN exported successfully Procesando bloque: FC Ttop Philosophy 01... Exportando FC Ttop Philosophy 01 como XML... 2025-06-12 20:12:05,386 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 01 exported successfully 2025-06-12 20:12:05,387 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 01 exported successfully Procesando bloque: FC Ttop Philosophy 02... Exportando FC Ttop Philosophy 02 como XML... 2025-06-12 20:12:05,436 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 02 exported successfully 2025-06-12 20:12:05,437 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 02 exported successfully Procesando bloque: FC Ttop Philosophy 03... Exportando FC Ttop Philosophy 03 como XML... 2025-06-12 20:12:05,472 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 03 exported successfully 2025-06-12 20:12:05,472 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 03 exported successfully Procesando bloque: FC Ttop Philosophy 04... Exportando FC Ttop Philosophy 04 como XML... 2025-06-12 20:12:05,504 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 04 exported successfully 2025-06-12 20:12:05,504 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 04 exported successfully Procesando bloque: FC Ttop Philosophy 05... Exportando FC Ttop Philosophy 05 como XML... 2025-06-12 20:12:05,546 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 05 exported successfully 2025-06-12 20:12:05,547 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 05 exported successfully Procesando bloque: FC Ttop Philosophy 06... Exportando FC Ttop Philosophy 06 como XML... 2025-06-12 20:12:05,590 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 06 exported successfully 2025-06-12 20:12:05,592 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 06 exported successfully Procesando bloque: FC Ttop Philosophy 07... Exportando FC Ttop Philosophy 07 como XML... 2025-06-12 20:12:05,629 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 07 exported successfully 2025-06-12 20:12:05,630 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 07 exported successfully Procesando bloque: FC Ttop Philosophy 08... Exportando FC Ttop Philosophy 08 como XML... 2025-06-12 20:12:05,667 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 08 exported successfully 2025-06-12 20:12:05,669 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 08 exported successfully Procesando bloque: FC Ttop Philosophy 09... Exportando FC Ttop Philosophy 09 como XML... 2025-06-12 20:12:05,716 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy 09 exported successfully 2025-06-12 20:12:05,719 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy 09 exported successfully Procesando bloque: FC Ttop Philosophy Manage... Exportando FC Ttop Philosophy Manage como XML... 2025-06-12 20:12:05,761 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Ttop Philosophy Manage exported successfully 2025-06-12 20:12:05,776 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Ttop Philosophy Manage exported successfully Procesando bloque: FC Air Philosophy 01... Exportando FC Air Philosophy 01 como XML... 2025-06-12 20:12:05,837 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy 01 exported successfully 2025-06-12 20:12:05,838 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy 01 exported successfully Procesando bloque: FC Air Philosophy 04... Exportando FC Air Philosophy 04 como XML... 2025-06-12 20:12:05,878 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy 04 exported successfully 2025-06-12 20:12:05,878 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy 04 exported successfully Procesando bloque: FC Air Philosophy 08... Exportando FC Air Philosophy 08 como XML... 2025-06-12 20:12:05,919 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy 08 exported successfully 2025-06-12 20:12:05,920 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy 08 exported successfully Procesando bloque: FC Air Philosophy 14... Exportando FC Air Philosophy 14 como XML... 2025-06-12 20:12:05,957 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy 14 exported successfully 2025-06-12 20:12:05,958 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy 14 exported successfully Procesando bloque: FC Air Philosophy 17... Exportando FC Air Philosophy 17 como XML... 2025-06-12 20:12:06,005 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy 17 exported successfully 2025-06-12 20:12:06,005 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy 17 exported successfully Procesando bloque: FC Air Philosophy 18... Exportando FC Air Philosophy 18 como XML... 2025-06-12 20:12:06,056 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy 18 exported successfully 2025-06-12 20:12:06,057 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy 18 exported successfully Procesando bloque: FC Air Philosophy Manage... Exportando FC Air Philosophy Manage como XML... 2025-06-12 20:12:06,090 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FC Air Philosophy Manage exported successfully 2025-06-12 20:12:06,091 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FC Air Philosophy Manage exported successfully Procesando bloque: FB Mot Manage Altivar 320... Exportando FB Mot Manage Altivar 320 como XML... 2025-06-12 20:12:06,151 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Mot Manage Altivar 320 exported successfully 2025-06-12 20:12:06,152 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Mot Manage Altivar 320 exported successfully Procesando bloque: FB Motors Manage... Exportando FB Motors Manage como XML... 2025-06-12 20:12:06,257 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB Motors Manage exported successfully 2025-06-12 20:12:06,272 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB Motors Manage exported successfully Procesando bloque: FB LIFO HMI Page... Exportando FB LIFO HMI Page como XML... 2025-06-12 20:12:06,306 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB LIFO HMI Page exported successfully 2025-06-12 20:12:06,308 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB LIFO HMI Page exported successfully Procesando bloque: FB_SICK_AFx60_PN... Exportando FB_SICK_AFx60_PN como XML... 2025-06-12 20:12:06,475 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FB_SICK_AFx60_PN exported successfully 2025-06-12 20:12:06,476 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FB_SICK_AFx60_PN exported successfully Exportando FB_SICK_AFx60_PN como SCL... 2025-06-12 20:12:06,630 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block FB_SICK_AFx60_PN external source successfully generated Procesando bloque: DB General Run... Exportando DB General Run como XML... 2025-06-12 20:12:06,671 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB General Run exported successfully 2025-06-12 20:12:06,672 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB General Run exported successfully Procesando bloque: DB HMI... Exportando DB HMI como XML... 2025-06-12 20:12:06,696 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI exported successfully 2025-06-12 20:12:06,697 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI exported successfully Procesando bloque: DB HMI Timer... Exportando DB HMI Timer como XML... 2025-06-12 20:12:06,722 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI Timer exported successfully 2025-06-12 20:12:06,723 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI Timer exported successfully Procesando bloque: DB_PA_HMI-PLC_DataOra... Exportando DB_PA_HMI-PLC_DataOra como XML... 2025-06-12 20:12:06,748 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB_PA_HMI-PLC_DataOra exported successfully 2025-06-12 20:12:06,750 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB_PA_HMI-PLC_DataOra exported successfully Procesando bloque: DB_SET_TIMEZONE... Exportando DB_SET_TIMEZONE como XML... 2025-06-12 20:12:06,775 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB_SET_TIMEZONE exported successfully 2025-06-12 20:12:06,776 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB_SET_TIMEZONE exported successfully Procesando bloque: DB HMI DateTime... Exportando DB HMI DateTime como XML... 2025-06-12 20:12:06,807 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI DateTime exported successfully 2025-06-12 20:12:06,808 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI DateTime exported successfully Procesando bloque: DB HMI Recipe Air... Exportando DB HMI Recipe Air como XML... 2025-06-12 20:12:06,833 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI Recipe Air exported successfully 2025-06-12 20:12:06,835 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI Recipe Air exported successfully Procesando bloque: DB HMI Recipe Pack... Exportando DB HMI Recipe Pack como XML... 2025-06-12 20:12:06,858 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI Recipe Pack exported successfully 2025-06-12 20:12:06,859 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI Recipe Pack exported successfully Procesando bloque: DB HMI Recipe TTop... Exportando DB HMI Recipe TTop como XML... 2025-06-12 20:12:06,889 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI Recipe TTop exported successfully 2025-06-12 20:12:06,892 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI Recipe TTop exported successfully Procesando bloque: DB CTR Air Alarms... Exportando DB CTR Air Alarms como XML... 2025-06-12 20:12:06,919 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB CTR Air Alarms exported successfully 2025-06-12 20:12:06,920 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB CTR Air Alarms exported successfully Procesando bloque: DB CTR General Alarms... Exportando DB CTR General Alarms como XML... 2025-06-12 20:12:06,944 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB CTR General Alarms exported successfully 2025-06-12 20:12:06,945 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB CTR General Alarms exported successfully Procesando bloque: DB CTR Pack Alarm... Exportando DB CTR Pack Alarm como XML... 2025-06-12 20:12:06,975 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB CTR Pack Alarm exported successfully 2025-06-12 20:12:06,976 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB CTR Pack Alarm exported successfully Procesando bloque: DB CTR TT Alarm... Exportando DB CTR TT Alarm como XML... 2025-06-12 20:12:07,006 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB CTR TT Alarm exported successfully 2025-06-12 20:12:07,007 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB CTR TT Alarm exported successfully Procesando bloque: DB CTR Warnings... Exportando DB CTR Warnings como XML... 2025-06-12 20:12:07,035 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB CTR Warnings exported successfully 2025-06-12 20:12:07,036 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB CTR Warnings exported successfully Procesando bloque: DB Mot Manage Altivar 320... Exportando DB Mot Manage Altivar 320 como XML... 2025-06-12 20:12:07,067 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB Mot Manage Altivar 320 exported successfully 2025-06-12 20:12:07,069 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB Mot Manage Altivar 320 exported successfully Procesando bloque: DB HMI CFG... Exportando DB HMI CFG como XML... 2025-06-12 20:12:07,102 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB HMI CFG exported successfully 2025-06-12 20:12:07,103 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB HMI CFG exported successfully Procesando bloque: DB PN/DP Diag List... Exportando DB PN/DP Diag List como XML... 2025-06-12 20:12:07,143 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB PN/DP Diag List exported successfully 2025-06-12 20:12:07,145 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB PN/DP Diag List exported successfully Procesando bloque: DB_Minimotor_Config... Exportando DB_Minimotor_Config como XML... 2025-06-12 20:12:07,170 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB_Minimotor_Config exported successfully 2025-06-12 20:12:07,171 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB_Minimotor_Config exported successfully Procesando bloque: DB_MiniMotor_PN_Device... Exportando DB_MiniMotor_PN_Device como XML... 2025-06-12 20:12:07,195 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB_MiniMotor_PN_Device exported successfully 2025-06-12 20:12:07,196 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB_MiniMotor_PN_Device exported successfully Procesando bloque: DB LIFO HMI Page_DB... Exportando DB LIFO HMI Page_DB como XML... 2025-06-12 20:12:07,221 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DB LIFO HMI Page_DB exported successfully 2025-06-12 20:12:07,222 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DB LIFO HMI Page_DB exported successfully Procesando bloque: DividerMain... Exportando DividerMain como XML... 2025-06-12 20:12:07,378 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DividerMain exported successfully 2025-06-12 20:12:07,380 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DividerMain exported successfully Procesando bloque: dividerInterface... Exportando dividerInterface como XML... 2025-06-12 20:12:07,411 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: dividerInterface exported successfully 2025-06-12 20:12:07,412 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - dividerInterface exported successfully Procesando bloque: dividerData... Exportando dividerData como XML... 2025-06-12 20:12:07,438 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: dividerData exported successfully 2025-06-12 20:12:07,439 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - dividerData exported successfully Procesando bloque: MC_Interpolator... Exportando MC_Interpolator como XML... 2025-06-12 20:12:07,480 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: MC_Interpolator exported successfully 2025-06-12 20:12:07,480 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - MC_Interpolator exported successfully Procesando bloque: MC_PreInterpolator... Exportando MC_PreInterpolator como XML... 2025-06-12 20:12:07,527 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: MC_PreInterpolator exported successfully 2025-06-12 20:12:07,528 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - MC_PreInterpolator exported successfully Procesando bloque: MC_Servo... Exportando MC_Servo como XML... 2025-06-12 20:12:07,628 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: MC_Servo exported successfully 2025-06-12 20:12:07,629 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - MC_Servo exported successfully Procesando bloque: Startup... Exportando Startup como XML... 2025-06-12 20:12:07,661 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: Startup exported successfully 2025-06-12 20:12:07,662 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - Startup exported successfully Procesando bloque: timingBeltData... Exportando timingBeltData como XML... 2025-06-12 20:12:07,687 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: timingBeltData exported successfully 2025-06-12 20:12:07,688 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - timingBeltData exported successfully Procesando bloque: TimingBeltManager... Exportando TimingBeltManager como XML... 2025-06-12 20:12:07,750 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: TimingBeltManager exported successfully 2025-06-12 20:12:07,751 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - TimingBeltManager exported successfully Procesando bloque: TimingBeltInterrupt... Exportando TimingBeltInterrupt como XML... 2025-06-12 20:12:07,797 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: TimingBeltInterrupt exported successfully 2025-06-12 20:12:07,797 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - TimingBeltInterrupt exported successfully Procesando bloque: timingBeltSetupData... Exportando timingBeltSetupData como XML... 2025-06-12 20:12:07,842 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: timingBeltSetupData exported successfully 2025-06-12 20:12:07,843 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - timingBeltSetupData exported successfully Procesando bloque: instTimingBeltRampGenerator... Exportando instTimingBeltRampGenerator como XML... 2025-06-12 20:12:07,866 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: instTimingBeltRampGenerator exported successfully 2025-06-12 20:12:07,868 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - instTimingBeltRampGenerator exported successfully Procesando bloque: alarmMask... Exportando alarmMask como XML... 2025-06-12 20:12:07,896 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: alarmMask exported successfully 2025-06-12 20:12:07,897 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - alarmMask exported successfully Procesando bloque: buttonsAndLamps_NotUsed... Exportando buttonsAndLamps_NotUsed como XML... 2025-06-12 20:12:07,926 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: buttonsAndLamps_NotUsed exported successfully 2025-06-12 20:12:07,927 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - buttonsAndLamps_NotUsed exported successfully Procesando bloque: electricalCabinet... Exportando electricalCabinet como XML... 2025-06-12 20:12:07,950 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: electricalCabinet exported successfully 2025-06-12 20:12:07,952 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - electricalCabinet exported successfully Procesando bloque: MachineMain... Exportando MachineMain como XML... 2025-06-12 20:12:08,005 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: MachineMain exported successfully 2025-06-12 20:12:08,006 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - MachineMain exported successfully Procesando bloque: AlarmsGeneric... Compilando bloque AlarmsGeneric... 2025-06-12 20:12:08,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Compile the PLC program block AlarmsGeneric. Result: 2025-06-12 20:12:08,731 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > General warnings > Inputs or outputs are used that do not exist in the configured hardware. 2025-06-12 20:12:08,731 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Warning: 98050_PLC > Compiling finished (errors: 0; warnings: 1) 2025-06-12 20:12:08,731 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Compile - Success: 98050_PLC > Program blocks > Divider > Machine > AlarmsGeneric (FC4) > Block was successfully compiled. Exportando AlarmsGeneric como XML... 2025-06-12 20:12:08,798 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: AlarmsGeneric exported successfully 2025-06-12 20:12:08,799 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - AlarmsGeneric exported successfully Procesando bloque: LampsGeneric... Exportando LampsGeneric como XML... 2025-06-12 20:12:08,835 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: LampsGeneric exported successfully 2025-06-12 20:12:08,836 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - LampsGeneric exported successfully Procesando bloque: Clocks... Exportando Clocks como XML... 2025-06-12 20:12:08,869 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: Clocks exported successfully 2025-06-12 20:12:08,870 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - Clocks exported successfully Procesando bloque: clock... Exportando clock como XML... 2025-06-12 20:12:08,894 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: clock exported successfully 2025-06-12 20:12:08,894 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - clock exported successfully Procesando bloque: machineData... Exportando machineData como XML... 2025-06-12 20:12:08,927 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: machineData exported successfully 2025-06-12 20:12:08,928 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - machineData exported successfully Procesando bloque: AlarmManagement... Exportando AlarmManagement como XML... 2025-06-12 20:12:08,985 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: AlarmManagement exported successfully 2025-06-12 20:12:08,987 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - AlarmManagement exported successfully Exportando AlarmManagement como SCL... 2025-06-12 20:12:09,028 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block AlarmManagement external source successfully generated Procesando bloque: MachineCycle... Exportando MachineCycle como XML... 2025-06-12 20:12:09,121 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: MachineCycle exported successfully 2025-06-12 20:12:09,122 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - MachineCycle exported successfully Procesando bloque: _instMachineCycle... Exportando _instMachineCycle como XML... 2025-06-12 20:12:09,151 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _instMachineCycle exported successfully 2025-06-12 20:12:09,153 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _instMachineCycle exported successfully Procesando bloque: _instAlarmPresence... Exportando _instAlarmPresence como XML... 2025-06-12 20:12:09,176 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _instAlarmPresence exported successfully 2025-06-12 20:12:09,177 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _instAlarmPresence exported successfully Procesando bloque: AlarmPresenceAndAcknowledge... Exportando AlarmPresenceAndAcknowledge como XML... 2025-06-12 20:12:09,369 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: AlarmPresenceAndAcknowledge exported successfully 2025-06-12 20:12:09,371 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - AlarmPresenceAndAcknowledge exported successfully Exportando AlarmPresenceAndAcknowledge como SCL... 2025-06-12 20:12:09,422 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block AlarmPresenceAndAcknowledge external source successfully generated Procesando bloque: SeamlessDivider_Main... Exportando SeamlessDivider_Main como XML... 2025-06-12 20:12:09,524 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: SeamlessDivider_Main exported successfully 2025-06-12 20:12:09,540 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - SeamlessDivider_Main exported successfully Exportando SeamlessDivider_Main como SCL... 2025-06-12 20:12:09,619 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block SeamlessDivider_Main external source successfully generated Procesando bloque: SeamlessDivider_Technology_MCInterrupt... Exportando SeamlessDivider_Technology_MCInterrupt como XML... 2025-06-12 20:12:09,757 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: SeamlessDivider_Technology_MCInterrupt exported successfully 2025-06-12 20:12:09,758 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - SeamlessDivider_Technology_MCInterrupt exported successfully Exportando SeamlessDivider_Technology_MCInterrupt como SCL... 2025-06-12 20:12:09,821 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block SeamlessDivider_Technology_MCInterrupt external source successfully generated Procesando bloque: SeamlessDivider_Technology... Exportando SeamlessDivider_Technology como XML... 2025-06-12 20:12:10,066 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: SeamlessDivider_Technology exported successfully 2025-06-12 20:12:10,068 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - SeamlessDivider_Technology exported successfully Exportando SeamlessDivider_Technology como SCL... 2025-06-12 20:12:10,192 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block SeamlessDivider_Technology external source successfully generated Procesando bloque: inv_SIEM_G120... Exportando inv_SIEM_G120 como XML... 2025-06-12 20:12:10,285 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: inv_SIEM_G120 exported successfully 2025-06-12 20:12:10,286 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - inv_SIEM_G120 exported successfully Procesando bloque: RampGenerator... Exportando RampGenerator como XML... 2025-06-12 20:12:10,363 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: RampGenerator exported successfully 2025-06-12 20:12:10,364 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - RampGenerator exported successfully Exportando RampGenerator como SCL... 2025-06-12 20:12:10,405 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block RampGenerator external source successfully generated Procesando bloque: LCamHdl_CreateCamAdvanced... Exportando LCamHdl_CreateCamAdvanced como XML... 2025-06-12 20:12:10,524 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: LCamHdl_CreateCamAdvanced exported successfully 2025-06-12 20:12:10,525 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - LCamHdl_CreateCamAdvanced exported successfully Exportando LCamHdl_CreateCamAdvanced como SCL... 2025-06-12 20:12:10,527 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock _PrivateProcessMessage - PLC program block LCamHdl_CreateCamAdvanced is know how protected, so ignore this Procesando bloque: CHECK_AXIS_POSITION... Exportando CHECK_AXIS_POSITION como XML... 2025-06-12 20:12:10,570 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: CHECK_AXIS_POSITION exported successfully 2025-06-12 20:12:10,571 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - CHECK_AXIS_POSITION exported successfully Exportando CHECK_AXIS_POSITION como SCL... 2025-06-12 20:12:10,621 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block CHECK_AXIS_POSITION external source successfully generated Procesando bloque: AxisTechnologyPositioning_GetData... Exportando AxisTechnologyPositioning_GetData como XML... 2025-06-12 20:12:10,685 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: AxisTechnologyPositioning_GetData exported successfully 2025-06-12 20:12:10,686 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - AxisTechnologyPositioning_GetData exported successfully Procesando bloque: AxisTechnologyPositioning... Exportando AxisTechnologyPositioning como XML... 2025-06-12 20:12:10,934 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: AxisTechnologyPositioning exported successfully 2025-06-12 20:12:10,936 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - AxisTechnologyPositioning exported successfully Procesando bloque: selections... Exportando selections como XML... 2025-06-12 20:12:10,980 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: selections exported successfully 2025-06-12 20:12:10,981 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - selections exported successfully Procesando bloque: recipe... Exportando recipe como XML... 2025-06-12 20:12:11,008 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: recipe exported successfully 2025-06-12 20:12:11,009 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - recipe exported successfully Procesando bloque: alarms... Exportando alarms como XML... 2025-06-12 20:12:11,039 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: alarms exported successfully 2025-06-12 20:12:11,040 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - alarms exported successfully Procesando bloque: _hmiShitData... Exportando _hmiShitData como XML... 2025-06-12 20:12:11,063 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _hmiShitData exported successfully 2025-06-12 20:12:11,064 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _hmiShitData exported successfully Procesando bloque: SignalTtopConveyors... Exportando SignalTtopConveyors como XML... 2025-06-12 20:12:11,152 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: SignalTtopConveyors exported successfully 2025-06-12 20:12:11,153 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - SignalTtopConveyors exported successfully Procesando bloque: DataConveyors... Exportando DataConveyors como XML... 2025-06-12 20:12:11,178 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DataConveyors exported successfully 2025-06-12 20:12:11,179 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DataConveyors exported successfully Procesando bloque: ConveyorConsent... Exportando ConveyorConsent como XML... 2025-06-12 20:12:11,213 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: ConveyorConsent exported successfully 2025-06-12 20:12:11,214 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - ConveyorConsent exported successfully Procesando bloque: conveyorConsentData... Exportando conveyorConsentData como XML... 2025-06-12 20:12:11,240 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: conveyorConsentData exported successfully 2025-06-12 20:12:11,241 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - conveyorConsentData exported successfully Procesando bloque: VirtualMasterManager... Exportando VirtualMasterManager como XML... 2025-06-12 20:12:11,284 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: VirtualMasterManager exported successfully 2025-06-12 20:12:11,285 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - VirtualMasterManager exported successfully Exportando VirtualMasterManager como SCL... 2025-06-12 20:12:11,322 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock GenerateSource - PLC program block VirtualMasterManager external source successfully generated Procesando bloque: _instVirtualMaster... Exportando _instVirtualMaster como XML... 2025-06-12 20:12:11,371 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _instVirtualMaster exported successfully 2025-06-12 20:12:11,372 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _instVirtualMaster exported successfully Procesando bloque: virtualMasterData... Exportando virtualMasterData como XML... 2025-06-12 20:12:11,400 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: virtualMasterData exported successfully 2025-06-12 20:12:11,402 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - virtualMasterData exported successfully Procesando bloque: debugData... Exportando debugData como XML... 2025-06-12 20:12:11,425 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: debugData exported successfully 2025-06-12 20:12:11,426 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - debugData exported successfully Procesando bloque: FcMainConfig... Exportando FcMainConfig como XML... 2025-06-12 20:12:11,459 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FcMainConfig exported successfully 2025-06-12 20:12:11,460 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FcMainConfig exported successfully Procesando bloque: FcTonStruct... Exportando FcTonStruct como XML... 2025-06-12 20:12:11,503 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FcTonStruct exported successfully 2025-06-12 20:12:11,504 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FcTonStruct exported successfully Procesando bloque: FcTon... Exportando FcTon como XML... 2025-06-12 20:12:11,541 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FcTon exported successfully 2025-06-12 20:12:11,542 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FcTon exported successfully Procesando bloque: FcHmiData... Exportando FcHmiData como XML... 2025-06-12 20:12:11,619 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FcHmiData exported successfully 2025-06-12 20:12:11,619 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FcHmiData exported successfully Procesando bloque: HmiData... Exportando HmiData como XML... 2025-06-12 20:12:11,646 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: HmiData exported successfully 2025-06-12 20:12:11,647 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - HmiData exported successfully Procesando bloque: FcHmiRcpDivider... Exportando FcHmiRcpDivider como XML... 2025-06-12 20:12:11,692 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FcHmiRcpDivider exported successfully 2025-06-12 20:12:11,693 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FcHmiRcpDivider exported successfully Procesando bloque: HmiRcpDivider... Exportando HmiRcpDivider como XML... 2025-06-12 20:12:11,721 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: HmiRcpDivider exported successfully 2025-06-12 20:12:11,721 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - HmiRcpDivider exported successfully Procesando bloque: DbHmiDateTime... Exportando DbHmiDateTime como XML... 2025-06-12 20:12:11,751 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DbHmiDateTime exported successfully 2025-06-12 20:12:11,752 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DbHmiDateTime exported successfully Procesando bloque: DbHmiTimeZone... Exportando DbHmiTimeZone como XML... 2025-06-12 20:12:11,779 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DbHmiTimeZone exported successfully 2025-06-12 20:12:11,779 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DbHmiTimeZone exported successfully Procesando bloque: FcHmiDateTime... Exportando FcHmiDateTime como XML... 2025-06-12 20:12:11,830 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: FcHmiDateTime exported successfully 2025-06-12 20:12:11,831 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - FcHmiDateTime exported successfully Procesando bloque: DbSetTimeZone... Exportando DbSetTimeZone como XML... 2025-06-12 20:12:11,856 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: DbSetTimeZone exported successfully 2025-06-12 20:12:11,857 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - DbSetTimeZone exported successfully Procesando bloque: _instDivider... Exportando _instDivider como XML... 2025-06-12 20:12:11,898 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _instDivider exported successfully 2025-06-12 20:12:11,899 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _instDivider exported successfully Procesando bloque: _instDivider_PostServo... Exportando _instDivider_PostServo como XML... 2025-06-12 20:12:11,938 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _instDivider_PostServo exported successfully 2025-06-12 20:12:11,939 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _instDivider_PostServo exported successfully Procesando bloque: _instDividerMotion... Exportando _instDividerMotion como XML... 2025-06-12 20:12:12,053 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - PLC program block: _instDividerMotion exported successfully 2025-06-12 20:12:12,055 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.ProgramBlock Export - _instDividerMotion exported successfully Resumen de exportación de bloques: Exportados=290, Omitidos/Errores=1 [PLC: 98050_PLC] Exportando tipos de datos PLC (UDTs)... Destino: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source\98050_PLC\PlcDataTypes Se encontraron 129 UDTs. Procesando UDT: UDT Air Energy Saving... Exportando UDT Air Energy Saving... 2025-06-12 20:12:12,208 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Air Energy Saving exported successfully 2025-06-12 20:12:12,223 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Air Energy Saving exported successfully Procesando UDT: UDT Fifo... Exportando UDT Fifo... 2025-06-12 20:12:12,255 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Fifo exported successfully 2025-06-12 20:12:12,256 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Fifo exported successfully Procesando UDT: UDT Lubrication... Exportando UDT Lubrication... 2025-06-12 20:12:12,279 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Lubrication exported successfully 2025-06-12 20:12:12,280 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Lubrication exported successfully Procesando UDT: UDT Philosofy Data TTOP... Exportando UDT Philosofy Data TTOP... 2025-06-12 20:12:12,307 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Philosofy Data TTOP exported successfully 2025-06-12 20:12:12,308 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Philosofy Data TTOP exported successfully Procesando UDT: UDT Run... Exportando UDT Run... 2025-06-12 20:12:12,349 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Run exported successfully 2025-06-12 20:12:12,352 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Run exported successfully Procesando UDT: UDT Air Obstruction... Exportando UDT Air Obstruction... 2025-06-12 20:12:12,382 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Air Obstruction exported successfully 2025-06-12 20:12:12,384 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Air Obstruction exported successfully Procesando UDT: UDT EcoSync Liner... Exportando UDT EcoSync Liner... 2025-06-12 20:12:12,404 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT EcoSync Liner exported successfully 2025-06-12 20:12:12,405 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT EcoSync Liner exported successfully Procesando UDT: UDT Syncro+ Data... Exportando UDT Syncro+ Data... 2025-06-12 20:12:12,426 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Syncro+ Data exported successfully 2025-06-12 20:12:12,427 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Syncro+ Data exported successfully Procesando UDT: UDT Syncro+ Liner... Exportando UDT Syncro+ Liner... 2025-06-12 20:12:12,446 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Syncro+ Liner exported successfully 2025-06-12 20:12:12,447 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Syncro+ Liner exported successfully Procesando UDT: UDT Timer... Exportando UDT Timer... 2025-06-12 20:12:12,465 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Timer exported successfully 2025-06-12 20:12:12,467 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Timer exported successfully Procesando UDT: UDT_LubeZone... Exportando UDT_LubeZone... 2025-06-12 20:12:12,489 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT_LubeZone exported successfully 2025-06-12 20:12:12,489 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT_LubeZone exported successfully Procesando UDT: UDT_AlrLube... Exportando UDT_AlrLube... 2025-06-12 20:12:12,508 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT_AlrLube exported successfully 2025-06-12 20:12:12,510 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT_AlrLube exported successfully Procesando UDT: UDT_AlrLubrification... Exportando UDT_AlrLubrification... 2025-06-12 20:12:12,530 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT_AlrLubrification exported successfully 2025-06-12 20:12:12,535 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT_AlrLubrification exported successfully Procesando UDT: UDT_LubrificationZone... Exportando UDT_LubrificationZone... 2025-06-12 20:12:12,553 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT_LubrificationZone exported successfully 2025-06-12 20:12:12,553 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT_LubrificationZone exported successfully Procesando UDT: UDT Signal... Exportando UDT Signal... 2025-06-12 20:12:12,577 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Signal exported successfully 2025-06-12 20:12:12,578 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Signal exported successfully Procesando UDT: UDT Motor... Exportando UDT Motor... 2025-06-12 20:12:12,612 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Motor exported successfully 2025-06-12 20:12:12,613 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Motor exported successfully Procesando UDT: UDT Timer ONOFF... Exportando UDT Timer ONOFF... 2025-06-12 20:12:12,632 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Timer ONOFF exported successfully 2025-06-12 20:12:12,634 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Timer ONOFF exported successfully Procesando UDT: Timer... Exportando Timer... 2025-06-12 20:12:12,656 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Timer exported successfully 2025-06-12 20:12:12,657 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Timer exported successfully Procesando UDT: Rcp... Exportando Rcp... 2025-06-12 20:12:12,673 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Rcp exported successfully 2025-06-12 20:12:12,675 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Rcp exported successfully Procesando UDT: ST_SICK_AFx60... Exportando ST_SICK_AFx60... 2025-06-12 20:12:12,704 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: ST_SICK_AFx60 exported successfully 2025-06-12 20:12:12,705 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - ST_SICK_AFx60 exported successfully Procesando UDT: ST_SICK_AFx60_Error... Exportando ST_SICK_AFx60_Error... 2025-06-12 20:12:12,724 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: ST_SICK_AFx60_Error exported successfully 2025-06-12 20:12:12,725 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - ST_SICK_AFx60_Error exported successfully Procesando UDT: Ctr_MiniMotor_ProfVelocity... Exportando Ctr_MiniMotor_ProfVelocity... 2025-06-12 20:12:12,746 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Ctr_MiniMotor_ProfVelocity exported successfully 2025-06-12 20:12:12,747 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Ctr_MiniMotor_ProfVelocity exported successfully Procesando UDT: Ctr_MiniMotor_ProfPosition... Exportando Ctr_MiniMotor_ProfPosition... 2025-06-12 20:12:12,773 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Ctr_MiniMotor_ProfPosition exported successfully 2025-06-12 20:12:12,773 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Ctr_MiniMotor_ProfPosition exported successfully Procesando UDT: Ctr_MiniMotor_Home... Exportando Ctr_MiniMotor_Home... 2025-06-12 20:12:12,794 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Ctr_MiniMotor_Home exported successfully 2025-06-12 20:12:12,795 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Ctr_MiniMotor_Home exported successfully Procesando UDT: Ctr_MiniMotor_ProfTorque... Exportando Ctr_MiniMotor_ProfTorque... 2025-06-12 20:12:12,820 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Ctr_MiniMotor_ProfTorque exported successfully 2025-06-12 20:12:12,821 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Ctr_MiniMotor_ProfTorque exported successfully Procesando UDT: DBS55_PN_CtrWord... Exportando DBS55_PN_CtrWord... 2025-06-12 20:12:12,844 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: DBS55_PN_CtrWord exported successfully 2025-06-12 20:12:12,844 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - DBS55_PN_CtrWord exported successfully Procesando UDT: DBS55_PN_Input... Exportando DBS55_PN_Input... 2025-06-12 20:12:12,872 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: DBS55_PN_Input exported successfully 2025-06-12 20:12:12,872 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - DBS55_PN_Input exported successfully Procesando UDT: DBS55_PN_Output... Exportando DBS55_PN_Output... 2025-06-12 20:12:12,896 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: DBS55_PN_Output exported successfully 2025-06-12 20:12:12,896 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - DBS55_PN_Output exported successfully Procesando UDT: DBS55_PN_StWord... Exportando DBS55_PN_StWord... 2025-06-12 20:12:12,923 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: DBS55_PN_StWord exported successfully 2025-06-12 20:12:12,924 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - DBS55_PN_StWord exported successfully Procesando UDT: UDT RCP STATUS... Exportando UDT RCP STATUS... 2025-06-12 20:12:12,956 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT RCP STATUS exported successfully 2025-06-12 20:12:12,957 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT RCP STATUS exported successfully Procesando UDT: Get/Put... Exportando Get/Put... 2025-06-12 20:12:12,978 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: Get/Put exported successfully 2025-06-12 20:12:12,979 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - Get/Put exported successfully Procesando UDT: UDT AnalogDevice... Exportando UDT AnalogDevice... 2025-06-12 20:12:13,003 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT AnalogDevice exported successfully 2025-06-12 20:12:13,004 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT AnalogDevice exported successfully Procesando UDT: UDT Scale Data... Exportando UDT Scale Data... 2025-06-12 20:12:13,021 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT Scale Data exported successfully 2025-06-12 20:12:13,022 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT Scale Data exported successfully Procesando UDT: UDT PID Setup... Exportando UDT PID Setup... 2025-06-12 20:12:13,042 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: UDT PID Setup exported successfully 2025-06-12 20:12:13,043 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - UDT PID Setup exported successfully Procesando UDT: typeMachineCycleInterface... Exportando typeMachineCycleInterface... 2025-06-12 20:12:13,067 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: typeMachineCycleInterface exported successfully 2025-06-12 20:12:13,071 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - typeMachineCycleInterface exported successfully Procesando UDT: typeSeamlessDividerBlocksSharedData... Exportando typeSeamlessDividerBlocksSharedData... 2025-06-12 20:12:13,098 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: typeSeamlessDividerBlocksSharedData exported successfully 2025-06-12 20:12:13,098 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - typeSeamlessDividerBlocksSharedData exported successfully Procesando UDT: typeSeamlessDividerInterface... Exportando typeSeamlessDividerInterface... 2025-06-12 20:12:13,137 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: typeSeamlessDividerInterface exported successfully 2025-06-12 20:12:13,138 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - typeSeamlessDividerInterface exported successfully Procesando UDT: typeSeamlessDividerMotionTechnologyInterface... Exportando typeSeamlessDividerMotionTechnologyInterface... 2025-06-12 20:12:13,173 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: typeSeamlessDividerMotionTechnologyInterface exported successfully 2025-06-12 20:12:13,173 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - typeSeamlessDividerMotionTechnologyInterface exported successfully Procesando UDT: typeAxisPositioningInterface... Exportando typeAxisPositioningInterface... 2025-06-12 20:12:13,204 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: typeAxisPositioningInterface exported successfully 2025-06-12 20:12:13,204 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - typeAxisPositioningInterface exported successfully Procesando UDT: LCamHdl_typeAdvancedConfig... Exportando LCamHdl_typeAdvancedConfig... 2025-06-12 20:12:13,238 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: LCamHdl_typeAdvancedConfig exported successfully 2025-06-12 20:12:13,240 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - LCamHdl_typeAdvancedConfig exported successfully Procesando UDT: LCamHdl_typeAdvancedElement... Exportando LCamHdl_typeAdvancedElement... 2025-06-12 20:12:13,263 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: LCamHdl_typeAdvancedElement exported successfully 2025-06-12 20:12:13,264 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - LCamHdl_typeAdvancedElement exported successfully Procesando UDT: LCamHdl_typeDiagnostics... Exportando LCamHdl_typeDiagnostics... 2025-06-12 20:12:13,292 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: LCamHdl_typeDiagnostics exported successfully 2025-06-12 20:12:13,293 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - LCamHdl_typeDiagnostics exported successfully Procesando UDT: typeAxisTechnologyInterface... Exportando typeAxisTechnologyInterface... 2025-06-12 20:12:13,326 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type: typeAxisTechnologyInterface exported successfully 2025-06-12 20:12:13,327 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - typeAxisTechnologyInterface exported successfully Procesando UDT: TO_Struct_Actor... Exportando TO_Struct_Actor... 2025-06-12 20:12:13,331 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Actor is know how protected, so ignore this 2025-06-12 20:12:13,334 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Actor exported successfully Procesando UDT: TO_Struct_ActorInterface... Exportando TO_Struct_ActorInterface... 2025-06-12 20:12:13,338 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ActorInterface is know how protected, so ignore this 2025-06-12 20:12:13,339 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ActorInterface exported successfully Procesando UDT: TO_Struct_ActorDriveParameter... Exportando TO_Struct_ActorDriveParameter... 2025-06-12 20:12:13,342 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ActorDriveParameter is know how protected, so ignore this 2025-06-12 20:12:13,343 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ActorDriveParameter exported successfully Procesando UDT: TO_Struct_LinearMotorActorDriveParameter... Exportando TO_Struct_LinearMotorActorDriveParameter... 2025-06-12 20:12:13,345 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_LinearMotorActorDriveParameter is know how protected, so ignore this 2025-06-12 20:12:13,346 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_LinearMotorActorDriveParameter exported successfully Procesando UDT: TO_Struct_TorqueLimiting... Exportando TO_Struct_TorqueLimiting... 2025-06-12 20:12:13,352 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_TorqueLimiting is know how protected, so ignore this 2025-06-12 20:12:13,353 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_TorqueLimiting exported successfully Procesando UDT: TO_Struct_TorqueLimitingLimitDefaults... Exportando TO_Struct_TorqueLimitingLimitDefaults... 2025-06-12 20:12:13,356 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_TorqueLimitingLimitDefaults is know how protected, so ignore this 2025-06-12 20:12:13,357 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_TorqueLimitingLimitDefaults exported successfully Procesando UDT: TO_Struct_LoadGear... Exportando TO_Struct_LoadGear... 2025-06-12 20:12:13,360 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_LoadGear is know how protected, so ignore this 2025-06-12 20:12:13,361 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_LoadGear exported successfully Procesando UDT: TO_Struct_DynamicLimits... Exportando TO_Struct_DynamicLimits... 2025-06-12 20:12:13,368 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_DynamicLimits is know how protected, so ignore this 2025-06-12 20:12:13,369 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_DynamicLimits exported successfully Procesando UDT: TO_Struct_DynamicDefaults... Exportando TO_Struct_DynamicDefaults... 2025-06-12 20:12:13,373 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_DynamicDefaults is know how protected, so ignore this 2025-06-12 20:12:13,374 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_DynamicDefaults exported successfully Procesando UDT: TO_Struct_Override... Exportando TO_Struct_Override... 2025-06-12 20:12:13,377 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Override is know how protected, so ignore this 2025-06-12 20:12:13,378 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Override exported successfully Procesando UDT: TO_Struct_Units... Exportando TO_Struct_Units... 2025-06-12 20:12:13,381 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Units is know how protected, so ignore this 2025-06-12 20:12:13,383 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Units exported successfully Procesando UDT: TO_Struct_StatusDrive... Exportando TO_Struct_StatusDrive... 2025-06-12 20:12:13,388 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusDrive is know how protected, so ignore this 2025-06-12 20:12:13,389 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusDrive exported successfully Procesando UDT: TO_Struct_StatusTorqueData... Exportando TO_Struct_StatusTorqueData... 2025-06-12 20:12:13,394 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusTorqueData is know how protected, so ignore this 2025-06-12 20:12:13,394 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusTorqueData exported successfully Procesando UDT: TO_Struct_StatusMotionIn... Exportando TO_Struct_StatusMotionIn... 2025-06-12 20:12:13,398 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusMotionIn is know how protected, so ignore this 2025-06-12 20:12:13,399 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusMotionIn exported successfully Procesando UDT: TO_Struct_StatusInterpreterMotion... Exportando TO_Struct_StatusInterpreterMotion... 2025-06-12 20:12:13,404 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusInterpreterMotion is know how protected, so ignore this 2025-06-12 20:12:13,405 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusInterpreterMotion exported successfully Procesando UDT: TO_Struct_ErrorDetail... Exportando TO_Struct_ErrorDetail... 2025-06-12 20:12:13,408 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ErrorDetail is know how protected, so ignore this 2025-06-12 20:12:13,408 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ErrorDetail exported successfully Procesando UDT: TO_Struct_ControlPanel... Exportando TO_Struct_ControlPanel... 2025-06-12 20:12:13,413 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ControlPanel is know how protected, so ignore this 2025-06-12 20:12:13,414 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ControlPanel exported successfully Procesando UDT: TO_Struct_ControlPanelInput... Exportando TO_Struct_ControlPanelInput... 2025-06-12 20:12:13,419 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ControlPanelInput is know how protected, so ignore this 2025-06-12 20:12:13,420 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ControlPanelInput exported successfully Procesando UDT: TO_Struct_ControlPanelInputCmd... Exportando TO_Struct_ControlPanelInputCmd... 2025-06-12 20:12:13,423 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ControlPanelInputCmd is know how protected, so ignore this 2025-06-12 20:12:13,424 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ControlPanelInputCmd exported successfully Procesando UDT: TO_Struct_ControlPanelOutput... Exportando TO_Struct_ControlPanelOutput... 2025-06-12 20:12:13,428 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ControlPanelOutput is know how protected, so ignore this 2025-06-12 20:12:13,429 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ControlPanelOutput exported successfully Procesando UDT: TO_Struct_ControlPanelOutputCmd... Exportando TO_Struct_ControlPanelOutputCmd... 2025-06-12 20:12:13,432 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ControlPanelOutputCmd is know how protected, so ignore this 2025-06-12 20:12:13,433 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ControlPanelOutputCmd exported successfully Procesando UDT: TO_Struct_Internal... Exportando TO_Struct_Internal... 2025-06-12 20:12:13,438 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Internal is know how protected, so ignore this 2025-06-12 20:12:13,438 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Internal exported successfully Procesando UDT: TO_Struct_VirtualAxis... Exportando TO_Struct_VirtualAxis... 2025-06-12 20:12:13,442 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_VirtualAxis is know how protected, so ignore this 2025-06-12 20:12:13,443 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_VirtualAxis exported successfully Procesando UDT: TO_Struct_AxisSimulation... Exportando TO_Struct_AxisSimulation... 2025-06-12 20:12:13,448 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_AxisSimulation is know how protected, so ignore this 2025-06-12 20:12:13,450 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_AxisSimulation exported successfully Procesando UDT: TO_Struct_Clamping... Exportando TO_Struct_Clamping... 2025-06-12 20:12:13,455 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Clamping is know how protected, so ignore this 2025-06-12 20:12:13,455 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Clamping exported successfully Procesando UDT: TO_Struct_Sensor... Exportando TO_Struct_Sensor... 2025-06-12 20:12:13,459 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Sensor is know how protected, so ignore this 2025-06-12 20:12:13,460 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Sensor exported successfully Procesando UDT: TO_Struct_SensorInterface... Exportando TO_Struct_SensorInterface... 2025-06-12 20:12:13,464 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_SensorInterface is know how protected, so ignore this 2025-06-12 20:12:13,465 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_SensorInterface exported successfully Procesando UDT: TO_Struct_SensorParameter... Exportando TO_Struct_SensorParameter... 2025-06-12 20:12:13,471 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_SensorParameter is know how protected, so ignore this 2025-06-12 20:12:13,471 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_SensorParameter exported successfully Procesando UDT: TO_Struct_Backlash... Exportando TO_Struct_Backlash... 2025-06-12 20:12:13,476 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Backlash is know how protected, so ignore this 2025-06-12 20:12:13,477 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Backlash exported successfully Procesando UDT: TO_Struct_SensorActiveHoming... Exportando TO_Struct_SensorActiveHoming... 2025-06-12 20:12:13,484 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_SensorActiveHoming is know how protected, so ignore this 2025-06-12 20:12:13,485 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_SensorActiveHoming exported successfully Procesando UDT: TO_Struct_SensorPassiveHoming... Exportando TO_Struct_SensorPassiveHoming... 2025-06-12 20:12:13,491 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_SensorPassiveHoming is know how protected, so ignore this 2025-06-12 20:12:13,492 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_SensorPassiveHoming exported successfully Procesando UDT: TO_Struct_SensorMeasuringGear... Exportando TO_Struct_SensorMeasuringGear... 2025-06-12 20:12:13,497 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_SensorMeasuringGear is know how protected, so ignore this 2025-06-12 20:12:13,499 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_SensorMeasuringGear exported successfully Procesando UDT: TO_Struct_Extrapolation... Exportando TO_Struct_Extrapolation... 2025-06-12 20:12:13,508 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Extrapolation is know how protected, so ignore this 2025-06-12 20:12:13,508 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Extrapolation exported successfully Procesando UDT: TO_Struct_ExtrapolationSettings... Exportando TO_Struct_ExtrapolationSettings... 2025-06-12 20:12:13,512 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExtrapolationSettings is know how protected, so ignore this 2025-06-12 20:12:13,513 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExtrapolationSettings exported successfully Procesando UDT: TO_Struct_ExtrapolationPositionFilter... Exportando TO_Struct_ExtrapolationPositionFilter... 2025-06-12 20:12:13,523 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExtrapolationPositionFilter is know how protected, so ignore this 2025-06-12 20:12:13,524 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExtrapolationPositionFilter exported successfully Procesando UDT: TO_Struct_ExtrapolationVelocityFilter... Exportando TO_Struct_ExtrapolationVelocityFilter... 2025-06-12 20:12:13,531 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExtrapolationVelocityFilter is know how protected, so ignore this 2025-06-12 20:12:13,533 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExtrapolationVelocityFilter exported successfully Procesando UDT: TO_Struct_ExtrapolationVelocityTolerance... Exportando TO_Struct_ExtrapolationVelocityTolerance... 2025-06-12 20:12:13,539 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExtrapolationVelocityTolerance is know how protected, so ignore this 2025-06-12 20:12:13,539 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExtrapolationVelocityTolerance exported successfully Procesando UDT: TO_Struct_ExtrapolationHysteresis... Exportando TO_Struct_ExtrapolationHysteresis... 2025-06-12 20:12:13,543 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExtrapolationHysteresis is know how protected, so ignore this 2025-06-12 20:12:13,543 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExtrapolationHysteresis exported successfully Procesando UDT: TO_Struct_Mechanics... Exportando TO_Struct_Mechanics... 2025-06-12 20:12:13,546 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Mechanics is know how protected, so ignore this 2025-06-12 20:12:13,547 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Mechanics exported successfully Procesando UDT: TO_Struct_Properties... Exportando TO_Struct_Properties... 2025-06-12 20:12:13,553 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Properties is know how protected, so ignore this 2025-06-12 20:12:13,553 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Properties exported successfully Procesando UDT: TO_Struct_Modulo... Exportando TO_Struct_Modulo... 2025-06-12 20:12:13,556 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Modulo is know how protected, so ignore this 2025-06-12 20:12:13,557 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Modulo exported successfully Procesando UDT: TO_Struct_PositionLimitsSW... Exportando TO_Struct_PositionLimitsSW... 2025-06-12 20:12:13,562 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_PositionLimitsSW is know how protected, so ignore this 2025-06-12 20:12:13,562 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_PositionLimitsSW exported successfully Procesando UDT: TO_Struct_PositionLimitsHW... Exportando TO_Struct_PositionLimitsHW... 2025-06-12 20:12:13,568 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_PositionLimitsHW is know how protected, so ignore this 2025-06-12 20:12:13,569 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_PositionLimitsHW exported successfully Procesando UDT: TO_Struct_Homing... Exportando TO_Struct_Homing... 2025-06-12 20:12:13,576 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_Homing is know how protected, so ignore this 2025-06-12 20:12:13,577 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_Homing exported successfully Procesando UDT: TO_Struct_PositionControl... Exportando TO_Struct_PositionControl... 2025-06-12 20:12:13,587 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_PositionControl is know how protected, so ignore this 2025-06-12 20:12:13,587 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_PositionControl exported successfully Procesando UDT: TO_Struct_PositionDifferenceQuantification... Exportando TO_Struct_PositionDifferenceQuantification... 2025-06-12 20:12:13,591 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_PositionDifferenceQuantification is know how protected, so ignore this 2025-06-12 20:12:13,592 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_PositionDifferenceQuantification exported successfully Procesando UDT: TO_Struct_TorquePreControl... Exportando TO_Struct_TorquePreControl... 2025-06-12 20:12:13,596 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_TorquePreControl is know how protected, so ignore this 2025-06-12 20:12:13,597 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_TorquePreControl exported successfully Procesando UDT: TO_Struct_SetpointFilter... Exportando TO_Struct_SetpointFilter... 2025-06-12 20:12:13,605 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_SetpointFilter is know how protected, so ignore this 2025-06-12 20:12:13,605 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_SetpointFilter exported successfully Procesando UDT: TO_Struct_DynamicFilter... Exportando TO_Struct_DynamicFilter... 2025-06-12 20:12:13,610 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_DynamicFilter is know how protected, so ignore this 2025-06-12 20:12:13,610 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_DynamicFilter exported successfully Procesando UDT: TO_Struct_DynamicAxisModel... Exportando TO_Struct_DynamicAxisModel... 2025-06-12 20:12:13,614 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_DynamicAxisModel is know how protected, so ignore this 2025-06-12 20:12:13,616 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_DynamicAxisModel exported successfully Procesando UDT: TO_Struct_FollowingError... Exportando TO_Struct_FollowingError... 2025-06-12 20:12:13,621 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_FollowingError is know how protected, so ignore this 2025-06-12 20:12:13,622 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_FollowingError exported successfully Procesando UDT: TO_Struct_CrossPlcSynchronousOperation... Exportando TO_Struct_CrossPlcSynchronousOperation... 2025-06-12 20:12:13,625 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_CrossPlcSynchronousOperation is know how protected, so ignore this 2025-06-12 20:12:13,627 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_CrossPlcSynchronousOperation exported successfully Procesando UDT: TO_Struct_CrossPlcLeadingValueInterface... Exportando TO_Struct_CrossPlcLeadingValueInterface... 2025-06-12 20:12:13,632 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_CrossPlcLeadingValueInterface is know how protected, so ignore this 2025-06-12 20:12:13,633 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_CrossPlcLeadingValueInterface exported successfully Procesando UDT: TO_Struct_PositioningMonitoring... Exportando TO_Struct_PositioningMonitoring... 2025-06-12 20:12:13,638 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_PositioningMonitoring is know how protected, so ignore this 2025-06-12 20:12:13,639 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_PositioningMonitoring exported successfully Procesando UDT: TO_Struct_StandstillSignal... Exportando TO_Struct_StandstillSignal... 2025-06-12 20:12:13,644 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StandstillSignal is know how protected, so ignore this 2025-06-12 20:12:13,644 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StandstillSignal exported successfully Procesando UDT: TO_Struct_StatusPositioning... Exportando TO_Struct_StatusPositioning... 2025-06-12 20:12:13,651 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusPositioning is know how protected, so ignore this 2025-06-12 20:12:13,653 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusPositioning exported successfully Procesando UDT: TO_Struct_StatusServo... Exportando TO_Struct_StatusServo... 2025-06-12 20:12:13,659 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusServo is know how protected, so ignore this 2025-06-12 20:12:13,659 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusServo exported successfully Procesando UDT: TO_Struct_StatusProvidedLeadingValue... Exportando TO_Struct_StatusProvidedLeadingValue... 2025-06-12 20:12:13,663 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusProvidedLeadingValue is know how protected, so ignore this 2025-06-12 20:12:13,664 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusProvidedLeadingValue exported successfully Procesando UDT: TO_Struct_ProvidedLeadingValue... Exportando TO_Struct_ProvidedLeadingValue... 2025-06-12 20:12:13,670 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ProvidedLeadingValue is know how protected, so ignore this 2025-06-12 20:12:13,671 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ProvidedLeadingValue exported successfully Procesando UDT: TO_Struct_StatusSensor... Exportando TO_Struct_StatusSensor... 2025-06-12 20:12:13,676 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusSensor is know how protected, so ignore this 2025-06-12 20:12:13,677 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusSensor exported successfully Procesando UDT: TO_Struct_StatusExtrapolation... Exportando TO_Struct_StatusExtrapolation... 2025-06-12 20:12:13,680 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusExtrapolation is know how protected, so ignore this 2025-06-12 20:12:13,681 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusExtrapolation exported successfully Procesando UDT: TO_Struct_StatusKinematicsMotion... Exportando TO_Struct_StatusKinematicsMotion... 2025-06-12 20:12:13,687 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusKinematicsMotion is know how protected, so ignore this 2025-06-12 20:12:13,689 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusKinematicsMotion exported successfully Procesando UDT: PD_Gx_ZSW... Exportando PD_Gx_ZSW... 2025-06-12 20:12:13,693 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_Gx_ZSW is know how protected, so ignore this 2025-06-12 20:12:13,693 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_Gx_ZSW exported successfully Procesando UDT: PD_Gx_STW... Exportando PD_Gx_STW... 2025-06-12 20:12:13,698 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_Gx_STW is know how protected, so ignore this 2025-06-12 20:12:13,699 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_Gx_STW exported successfully Procesando UDT: PD_TEL105_IN... Exportando PD_TEL105_IN... 2025-06-12 20:12:13,706 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_TEL105_IN is know how protected, so ignore this 2025-06-12 20:12:13,706 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_TEL105_IN exported successfully Procesando UDT: PD_ZSW1_611UMode... Exportando PD_ZSW1_611UMode... 2025-06-12 20:12:13,711 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_ZSW1_611UMode is know how protected, so ignore this 2025-06-12 20:12:13,711 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_ZSW1_611UMode exported successfully Procesando UDT: PD_ZSW2_611UMode... Exportando PD_ZSW2_611UMode... 2025-06-12 20:12:13,716 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_ZSW2_611UMode is know how protected, so ignore this 2025-06-12 20:12:13,719 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_ZSW2_611UMode exported successfully Procesando UDT: PD_MELDW... Exportando PD_MELDW... 2025-06-12 20:12:13,727 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_MELDW is know how protected, so ignore this 2025-06-12 20:12:13,728 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_MELDW exported successfully Procesando UDT: PD_TEL105_OUT... Exportando PD_TEL105_OUT... 2025-06-12 20:12:13,735 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_TEL105_OUT is know how protected, so ignore this 2025-06-12 20:12:13,736 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_TEL105_OUT exported successfully Procesando UDT: PD_STW1_611UMode... Exportando PD_STW1_611UMode... 2025-06-12 20:12:13,741 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_STW1_611UMode is know how protected, so ignore this 2025-06-12 20:12:13,742 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_STW1_611UMode exported successfully Procesando UDT: PD_STW2_611UMode... Exportando PD_STW2_611UMode... 2025-06-12 20:12:13,747 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_STW2_611UMode is know how protected, so ignore this 2025-06-12 20:12:13,747 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_STW2_611UMode exported successfully Procesando UDT: TO_Struct_ExternalEncoder_Sensor... Exportando TO_Struct_ExternalEncoder_Sensor... 2025-06-12 20:12:13,753 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExternalEncoder_Sensor is know how protected, so ignore this 2025-06-12 20:12:13,754 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExternalEncoder_Sensor exported successfully Procesando UDT: TO_Struct_ExternalEncoder_Homing... Exportando TO_Struct_ExternalEncoder_Homing... 2025-06-12 20:12:13,758 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExternalEncoder_Homing is know how protected, so ignore this 2025-06-12 20:12:13,759 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExternalEncoder_Homing exported successfully Procesando UDT: TO_Struct_ExternalEncoder_Units... Exportando TO_Struct_ExternalEncoder_Units... 2025-06-12 20:12:13,763 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_ExternalEncoder_Units is know how protected, so ignore this 2025-06-12 20:12:13,764 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_ExternalEncoder_Units exported successfully Procesando UDT: TO_Struct_StatusSynchronizedMotion... Exportando TO_Struct_StatusSynchronizedMotion... 2025-06-12 20:12:13,770 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_StatusSynchronizedMotion is know how protected, so ignore this 2025-06-12 20:12:13,771 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_StatusSynchronizedMotion exported successfully Procesando UDT: TO_Struct_EffectiveLeadingValue... Exportando TO_Struct_EffectiveLeadingValue... 2025-06-12 20:12:13,776 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_EffectiveLeadingValue is know how protected, so ignore this 2025-06-12 20:12:13,777 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_EffectiveLeadingValue exported successfully Procesando UDT: TO_Struct_FunctionLeadingValue... Exportando TO_Struct_FunctionLeadingValue... 2025-06-12 20:12:13,783 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_FunctionLeadingValue is know how protected, so ignore this 2025-06-12 20:12:13,785 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_FunctionLeadingValue exported successfully Procesando UDT: TO_Struct_FunctionFollowingValue... Exportando TO_Struct_FunctionFollowingValue... 2025-06-12 20:12:13,790 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Struct_FunctionFollowingValue is know how protected, so ignore this 2025-06-12 20:12:13,790 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Struct_FunctionFollowingValue exported successfully Procesando UDT: PD_TEL83_IN... Exportando PD_TEL83_IN... 2025-06-12 20:12:13,793 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_TEL83_IN is know how protected, so ignore this 2025-06-12 20:12:13,794 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_TEL83_IN exported successfully Procesando UDT: PD_ZSW2_ENC... Exportando PD_ZSW2_ENC... 2025-06-12 20:12:13,805 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_ZSW2_ENC is know how protected, so ignore this 2025-06-12 20:12:13,805 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_ZSW2_ENC exported successfully Procesando UDT: PD_TEL83_OUT... Exportando PD_TEL83_OUT... 2025-06-12 20:12:13,810 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_TEL83_OUT is know how protected, so ignore this 2025-06-12 20:12:13,810 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_TEL83_OUT exported successfully Procesando UDT: PD_STW2_ENC... Exportando PD_STW2_ENC... 2025-06-12 20:12:13,815 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type PD_STW2_ENC is know how protected, so ignore this 2025-06-12 20:12:13,818 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PD_STW2_ENC exported successfully Procesando UDT: TO_Cam_Struct_InterpolationSettings... Exportando TO_Cam_Struct_InterpolationSettings... 2025-06-12 20:12:13,822 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Cam_Struct_InterpolationSettings is know how protected, so ignore this 2025-06-12 20:12:13,822 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Cam_Struct_InterpolationSettings exported successfully Procesando UDT: TO_Cam_Struct_StatusCam... Exportando TO_Cam_Struct_StatusCam... 2025-06-12 20:12:13,826 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Cam_Struct_StatusCam is know how protected, so ignore this 2025-06-12 20:12:13,826 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Cam_Struct_StatusCam exported successfully Procesando UDT: TO_Cam_Struct_PointData... Exportando TO_Cam_Struct_PointData... 2025-06-12 20:12:13,830 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Cam_Struct_PointData is know how protected, so ignore this 2025-06-12 20:12:13,831 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Cam_Struct_PointData exported successfully Procesando UDT: TO_Cam_Struct_SegmentData... Exportando TO_Cam_Struct_SegmentData... 2025-06-12 20:12:13,836 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - PLC user data type TO_Cam_Struct_SegmentData is know how protected, so ignore this 2025-06-12 20:12:13,837 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.UserDataType Export - TO_Cam_Struct_SegmentData exported successfully Resumen de exportación de UDTs: Exportados=129, Omitidos/Errores=0 [PLC: 98050_PLC] Exportando tablas de variables PLC... Destino: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source\98050_PLC\PlcTags Se encontraron 8 tablas de variables. Procesando tabla de variables: Default tag table... Exportando Default tag table... 2025-06-12 20:12:14,057 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: Default tag table exported successfully 2025-06-12 20:12:14,058 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - Default tag table exported successfully Procesando tabla de variables: Inputs... Exportando Inputs... 2025-06-12 20:12:14,104 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: Inputs exported successfully 2025-06-12 20:12:14,104 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - Inputs exported successfully Procesando tabla de variables: Outputs... Exportando Outputs... 2025-06-12 20:12:14,122 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: Outputs exported successfully 2025-06-12 20:12:14,123 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - Outputs exported successfully Procesando tabla de variables: CONSTANTS... Exportando CONSTANTS... 2025-06-12 20:12:14,152 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: CONSTANTS exported successfully 2025-06-12 20:12:14,167 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - CONSTANTS exported successfully Procesando tabla de variables: Merker... Exportando Merker... 2025-06-12 20:12:14,196 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: Merker exported successfully 2025-06-12 20:12:14,198 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - Merker exported successfully Procesando tabla de variables: LCamHdl_AdditionalConstants... Exportando LCamHdl_AdditionalConstants... 2025-06-12 20:12:14,224 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: LCamHdl_AdditionalConstants exported successfully 2025-06-12 20:12:14,225 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - LCamHdl_AdditionalConstants exported successfully Procesando tabla de variables: LCamHdl_ConfigConstants... Exportando LCamHdl_ConfigConstants... 2025-06-12 20:12:14,246 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: LCamHdl_ConfigConstants exported successfully 2025-06-12 20:12:14,247 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - LCamHdl_ConfigConstants exported successfully Procesando tabla de variables: LCamHdl_ProfileConstants... Exportando LCamHdl_ProfileConstants... 2025-06-12 20:12:14,273 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - PLC tag table: LCamHdl_ProfileConstants exported successfully 2025-06-12 20:12:14,276 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.PlcTagTable Export - LCamHdl_ProfileConstants exported successfully Resumen de exportación de tablas de variables: Exportados=8, Omitidos/Errores=0 --- Finalizado el procesamiento del PLC: 98050_PLC --- Proceso de exportación completado. Cerrando TIA Portal... 2025-06-12 20:12:14,278 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Portal ClosePortal - Close TIA Portal TIA Portal cerrado. Script finalizado. --- ERRORES (STDERR) --- Ninguno --- FIN DEL LOG ---