--- Log de Ejecución: x4.py --- Grupo: ObtainIOFromProjectTia Directorio de Trabajo: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source Inicio: 2025-06-19 19:05:36 Fin: 2025-06-19 19:06:33 Duración: 0:00:57.281042 Estado: SUCCESS (Código de Salida: 0) --- SALIDA ESTÁNDAR (STDOUT) --- --- Exportador de Referencias Cruzadas de TIA Portal --- Versión de TIA Portal detectada: 19.0 (de la extensión .ap19) Proyecto seleccionado: D:/Trabajo/VM/44 - 98050 - Fiera/InLavoro/PLC/98050_PLC_11/98050_PLC_11.ap19 Usando directorio base de exportación: D:\Trabajo\VM\44 - 98050 - Fiera\Reporte\ExportsTia\Source Conectando a TIA Portal V19.0... 2025-06-19 19:05:42,182 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Global OpenPortal - Start TIA Portal, please acknowledge the security dialog. 2025-06-19 19:05:42,202 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Global OpenPortal - With user interface Conectado a TIA Portal. 2025-06-19 19:05:52,371 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Portal GetProcessId - Process id: 24972 ID del proceso del Portal: 24972 2025-06-19 19:05:52,710 [1] INFO Siemens.TiaPortal.OpennessApi19.Implementations.Portal OpenProject - Open project... D:/Trabajo/VM/44 - 98050 - Fiera/InLavoro/PLC/98050_PLC_11/98050_PLC_11.ap19 Ocurrió un error inesperado: OpennessAccessException: Error when calling method 'OpenWithUpgrade' of type 'Siemens.Engineering.ProjectComposition'. Unable to open the project under path 'D:\Trabajo\VM\44 - 98050 - Fiera\InLavoro\PLC\98050_PLC_11\98050_PLC_11.ap19'. An error occurred while opening the project The project/library D:\Trabajo\VM\44 - 98050 - Fiera\InLavoro\PLC\98050_PLC_11\98050_PLC_11.ap19 cannot be accessed. It has already been opened by user Miguel on computer CSANUC. Note: If the application was not correctly closed, the open projects and libraries can only be opened again after a 2 minute delay. Script finalizado. --- ERRORES (STDERR) --- 2025-06-19 19:05:53,136 [1] ERROR Siemens.TiaPortal.OpennessApi19.Implementations.Portal OpenProject - Siemens.TiaPortal.OpennessContracts.OpennessAccessException: Error when calling method 'OpenWithUpgrade' of type 'Siemens.Engineering.ProjectComposition'. Unable to open the project under path 'D:\Trabajo\VM\44 - 98050 - Fiera\InLavoro\PLC\98050_PLC_11\98050_PLC_11.ap19'. An error occurred while opening the project The project/library D:\Trabajo\VM\44 - 98050 - Fiera\InLavoro\PLC\98050_PLC_11\98050_PLC_11.ap19 cannot be accessed. It has already been opened by user Miguel on computer CSANUC. Note: If the application was not correctly closed, the open projects and libraries can only be opened again after a 2 minute delay. Traceback (most recent call last): File "D:\Proyectos\Scripts\ParamManagerScripts\backend\script_groups\ObtainIOFromProjectTia\x4.py", line 455, in portal_instance, project_object = open_portal_and_project(tia_version, project_file) ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ File "D:\Proyectos\Scripts\ParamManagerScripts\backend\script_groups\ObtainIOFromProjectTia\x4.py", line 413, in open_portal_and_project project_obj = portal.open_project(project_file_path=str(project_file_path)) ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ ValueError: OpennessAccessException: Error when calling method 'OpenWithUpgrade' of type 'Siemens.Engineering.ProjectComposition'. Unable to open the project under path 'D:\Trabajo\VM\44 - 98050 - Fiera\InLavoro\PLC\98050_PLC_11\98050_PLC_11.ap19'. An error occurred while opening the project The project/library D:\Trabajo\VM\44 - 98050 - Fiera\InLavoro\PLC\98050_PLC_11\98050_PLC_11.ap19 cannot be accessed. It has already been opened by user Miguel on computer CSANUC. Note: If the application was not correctly closed, the open projects and libraries can only be opened again after a 2 minute delay. --- FIN DEL LOG ---