(* @PATH := '\/TASK2_ControlMain\/Blender_Logic' *) (* @SYMFILEFLAGS := '59392' *) PROGRAM Safeties VAR mAlarmHornReset : BOOL ; mWarningHornReset : BOOL ; mAlarmHornActive : SR ; mWarningHornActive : SR ; mProdBrixHighONS : R_TRIG ; mProdBrixLowONS : R_TRIG ; mProdCO2HighONS : R_TRIG ; mProdCO2LowONS : R_TRIG ; mWaterHighTempONS : R_TRIG ; mProdHighTempONS : R_TRIG ; mProdCondHighONS : R_TRIG ; mProdCondLowONS : R_TRIG ; mDummy : BOOL ; END_VAR VAR_OUTPUT EN_Out : BOOL ; END_VAR (* @END_DECLARATION := '0' *) _LD_BODY _NETWORKS : 81 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _EMPTY _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _NEGATIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 32 _LD_CONTACT gAuxVoltageOk _EXPRESSION _NEGATIV _LD_CONTACT gNotARecipe_Fault _EXPRESSION _POSITIV _LD_CONTACT gWaterPump_P1_Fault _EXPRESSION _POSITIV _LD_CONTACT gWaterPump_P5_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrupPump_P2_Fault _EXPRESSION _POSITIV _LD_CONTACT gRecircPump_P6_Fault _EXPRESSION _POSITIV _LD_CONTACT gWaterVFM_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrupMFM_Fault _EXPRESSION _POSITIV _LD_CONTACT gCO2MFM_Fault _EXPRESSION _POSITIV _LD_CONTACT gWaterValvePos_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrupValvePos_Fault _EXPRESSION _POSITIV _LD_CONTACT gCarboCO2ValvePos_Fault _EXPRESSION _POSITIV _LD_CONTACT gBlendErrorHighSyr_Fault _EXPRESSION _POSITIV _LD_CONTACT gBlendErrorLowSyr_Fault _EXPRESSION _POSITIV _LD_CONTACT gCarboCO2Error_LowCO2_Fault _EXPRESSION _POSITIV _LD_CONTACT gCarboCO2Error_HighCO2_Fault _EXPRESSION _POSITIV _LD_CONTACT gFC3102_Node1_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gET200_Node10_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gValvesBase_Node12_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gValvesBase_Node13_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gWater_VFM_Node20_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gSyrup_MFM_Node21_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gCarboCO2_MFM_Node22_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gAirLowPress_Fault _EXPRESSION _POSITIV _LD_CONTACT gCO2LowPress_Fault _EXPRESSION _POSITIV _LD_CONTACT gLineCO2LowPressure _EXPRESSION _POSITIV _LD_CONTACT gDensimeterCalError _EXPRESSION _POSITIV _LD_CONTACT gSyrTankLowLvl_Fault _EXPRESSION _POSITIV _LD_CONTACT gDeairTankLowLvl_Fault _EXPRESSION _POSITIV _LD_CONTACT gCIPRecircFlowMissing_Fault _EXPRESSION _POSITIV _LD_CONTACT gInManifoldNotReadyForProd _EXPRESSION _POSITIV _LD_CONTACT gInManifoldNotReadyForCIP _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET gHighPriorityAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 39 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm020 _EXPRESSION _POSITIV _LD_CONTACT gProductBrixTooHigh _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm021 _EXPRESSION _POSITIV _LD_CONTACT gProductBrixTooLow _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm022 _EXPRESSION _POSITIV _LD_CONTACT gProductCO2TooHigh _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm023 _EXPRESSION _POSITIV _LD_CONTACT gProductCO2TooLow _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_CONTACT gVacuumPump_P4_Fault _EXPRESSION _POSITIV _LD_CONTACT gProductPump_P3_Fault _EXPRESSION _POSITIV _LD_CONTACT gProdTankPressure_Fault _EXPRESSION _POSITIV _LD_CONTACT gVacuumTimeOut_Fault _EXPRESSION _POSITIV _LD_CONTACT gmPDS1000_NoOscillation _EXPRESSION _POSITIV _LD_CONTACT gmPDS1000_Error_Fault _EXPRESSION _POSITIV _LD_CONTACT gmPDS2000_Error_Fault _EXPRESSION _POSITIV _LD_CONTACT gPAmPDS_Error_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrRoomPump_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrBrixOutSpec_Fault _EXPRESSION _POSITIV _LD_CONTACT gManualSyrupDrainValve _EXPRESSION _POSITIV _LD_CONTACT gManualWaterDrainValve _EXPRESSION _POSITIV _LD_CONTACT gRinseTankPump_P5_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrupLineNotSelected _EXPRESSION _POSITIV _LD_CONTACT gInAmmoniaLowPressure _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm067 _EXPRESSION _POSITIV _LD_CONTACT gWaterTempTooHigh _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm068 _EXPRESSION _POSITIV _LD_CONTACT gProdTempTooHigh _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_CONTACT gLowCond_Node15_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gHighCond_Node16_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gSyrRoomWaterPump_Fault _EXPRESSION _POSITIV _LD_CONTACT gFillerCommFault _EXPRESSION _POSITIV _LD_CONTACT gCIPCommFault _EXPRESSION _POSITIV _LD_CONTACT gFlrCO2ValveEV46Pos_Fault _EXPRESSION _POSITIV _LD_CONTACT gProdValveEV62Pos_Fault _EXPRESSION _POSITIV _LD_CONTACT gDiffSensor_Analog_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrupDensityOutSpec_Fault _EXPRESSION _POSITIV _LD_CONTACT gSyrTankHighLvl_Fault _EXPRESSION _POSITIV _LD_CONTACT gAmmoniaCompressor_Fault _EXPRESSION _POSITIV _LD_CONTACT gDeaireationValveFault _EXPRESSION _POSITIV _LD_CONTACT gProdTankPressureValveFault _EXPRESSION _POSITIV _LD_CONTACT gWaterInletValveEV73Pos_Fault _EXPRESSION _POSITIV _LD_CONTACT gCIPInletValveEV74Pos_Fault _EXPRESSION _POSITIV _LD_CONTACT gPAmPDS_Node8_DP_Error _EXPRESSION _POSITIV _LD_CONTACT gPAmPDS_TransDropOUT _EXPRESSION _POSITIV _LD_CONTACT gUVLampHighTemperature _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET gLowPriorityAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gAuxVoltageOk _EXPRESSION _NEGATIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm001 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm001 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gNotARecipe_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm002 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm002 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gDensimeterCalError _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm003 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm003 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gFillerCommFault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm004 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm004 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCIPCommFault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm006 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm006 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gDiffSensor_Analog_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm007 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm007 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrTankHighLvl_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _LD_CONTACT gH_Alarm008 _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm008 _NETWORK _COMMENT Profibus Slave Valve Base 12 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gValvesBase_Node12_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm010 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm010 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Valve Base 13 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gValvesBase_Node13_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm011 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm011 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Low Conductimeter Node 15 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gLowCond_Node15_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm012 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm012 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Low Conductimeter Node 16 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gHighCond_Node16_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm013 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm013 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gProdTankPressureValveFault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm014 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm014 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gDeaireationValveFault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm015 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm015 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gWaterInletValveEV73Pos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm016 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm016 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCIPInletValveEV74Pos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm017 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm017 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gProdValveEV62Pos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm018 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm018 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gFlrCO2ValveEV46Pos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm019 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm019 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Product Brix Too High _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gProductBrixTooHigh _EXPRESSION _POSITIV _FUNCTIONBLOCK mProdBrixHighONS _BOX_EXPR : 1 _EMPTY _EXPRESSION _POSITIV R_TRIG _OUTPUTS : 0 _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm020 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm020 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Product Brix Too Low _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gProductBrixTooLow _EXPRESSION _POSITIV _FUNCTIONBLOCK mProdBrixLowONS _BOX_EXPR : 1 _EMPTY _EXPRESSION _POSITIV R_TRIG _OUTPUTS : 0 _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm021 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm021 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Product CO2 Too High _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gProductCO2TooHigh _EXPRESSION _POSITIV _FUNCTIONBLOCK mProdCO2HighONS _BOX_EXPR : 1 _EMPTY _EXPRESSION _POSITIV R_TRIG _OUTPUTS : 0 _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm022 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm022 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Product CO2 Too Low _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gProductCO2TooLow _EXPRESSION _POSITIV _FUNCTIONBLOCK mProdCO2LowONS _BOX_EXPR : 1 _EMPTY _EXPRESSION _POSITIV R_TRIG _OUTPUTS : 0 _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm023 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm023 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_AND _LD_OPERATOR : 2 _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gIn_ProdPumpFCReady _EXPRESSION _NEGATIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm025 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gH_Blender_OPT_BlendFillSystem _EXPRESSION _POSITIV _LD_CONTACT gH_Blender_OPT_Inverter _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm025 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P6 Recirculation Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gRecircPump_P6_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm026 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm026 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT mPDS1000_Error_Fault _END_COMMENT _LD_ASSIGN _LD_AND _LD_OPERATOR : 2 _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gmPDS1000_Error_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm027 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_CONTACT gH_Blender_OPT_Simulation _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm027 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Tube NOT Oscillating in Densimeter _END_COMMENT _LD_ASSIGN _LD_AND _LD_OPERATOR : 2 _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gmPDS1000_NoOscillation _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm028 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_CONTACT gH_Blender_OPT_Simulation _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm028 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P5 Water Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gWaterPump_P5_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm029 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm029 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P1 Water Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gWaterPump_P1_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm030 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm030 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P2 Syrup Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrupPump_P2_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm031 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm031 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P3 Product Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gProductPump_P3_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm032 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm032 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P4 Vacuum Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gVacuumPump_P4_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm033 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm033 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT P5 Rinse Tank Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gRinseTankPump_P5_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm034 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm034 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Water Flowmeter Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gWaterVFM_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm035 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm035 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Syrup Flowmeter Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrupMFM_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm036 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm036 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT CarboCO2 Flowmeter Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCO2MFM_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm037 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm037 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Water Modulating Valve Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gWaterValvePos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm038 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm038 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Syrup Modulating Valve Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrupValvePos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm039 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm039 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT CO2 Modulating Valve Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCarboCO2ValvePos_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm040 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm040 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Product Tank Pressure Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gProdTankPressure_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm041 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm041 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Blend Error High Syrup Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gBlendErrorHighSyr_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm042 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm042 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Blend Error Low Syrup Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gBlendErrorLowSyr_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm043 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm043 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Carbo CO2 Error High Co2 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCarboCO2Error_LowCO2_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm044 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm044 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Carbo CO2 Error Low Co2 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCarboCO2Error_HighCO2_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm045 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm045 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Vacuum TimeOut Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gVacuumTimeOut_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm046 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm046 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Local CIP PROGRAM Transfer TIME Out Elapsed _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCIPTransferProgTimeOut_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm047 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm047 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCIPRecircFlowMissing_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm048 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm048 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Master FC3102 Node 1 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gFC3102_Node1_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm050 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm050 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave ET200 Node 10 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gET200_Node10_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm051 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm051 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Promag53 Water FM Node 20 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gWater_VFM_Node20_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm052 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm052 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Promass63 Syrup FM Node 21 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrup_MFM_Node21_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm053 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm053 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Promass63 CO2 FM Node 22 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gCarboCO2_MFM_Node22_DP_Error _EXPRESSION _POSITIV _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gCarboStillProduct _EXPRESSION _POSITIV _LD_CONTACT gH_Blender_OPT_DoubleDeair _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm054 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm054 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Profibus Slave Product Pump Frequency Converter Node 4 Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gProduct_VFC_Node4_DP_Error _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm055 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm055 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT UPS Battery NOT ready - DOESN'T STOP THE MACHINE _END_COMMENT _LD_ASSIGN _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Blender_OPT_UPS_Siemens _EXPRESSION _POSITIV _LD_CONTACT DI_BatteryNotReady _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET gH_Alarm057 _NETWORK _COMMENT Profibus Adapter mPDS Error Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gPAmPDS_Error_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm058 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm058 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT mPDS2000_Error_Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gmPDS2000_Error_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm059 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm059 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Inlet Air Low Pressure Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gAirLowPress_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm060 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm060 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Inlet CO2 Low Pressure Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 3 _LD_CONTACT gCO2LowPress_Fault _EXPRESSION _POSITIV _LD_CONTACT gLineCO2LowPressure _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm061 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm061 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Deaireator Water MInimum Level _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gDeairTankLowLvl_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm062 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm062 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Syrup Tank Minimum Level _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrTankLowLvl_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm063 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm063 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Syrup Room Pump Fault _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrRoomPump_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm064 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm064 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT Syrup Brix Out OF Spec Alarm _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrBrixOutSpec_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm065 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm065 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gInAmmoniaLowPressure _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm066 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _SET gBlenderAlarm _OUTPUT _POSITIV _NO_SET gH_Alarm066 _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gWaterTempTooHigh _EXPRESSION _POSITIV _FUNCTIONBLOCK mWaterHighTempONS _BOX_EXPR : 1 _EMPTY _EXPRESSION _POSITIV R_TRIG _OUTPUTS : 0 _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm067 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm067 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gProdTempTooHigh _EXPRESSION _POSITIV _FUNCTIONBLOCK mProdHighTempONS _BOX_EXPR : 1 _EMPTY _EXPRESSION _POSITIV R_TRIG _OUTPUTS : 0 _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm068 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm068 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrRoomWaterPump_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm069 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm069 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrupDensityOutSpec_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm070 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm070 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gAmmoniaCompressor_Fault _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm072 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm072 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gUVLampHighTemperature _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm075 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm075 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gInUVLampAlarm _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm076 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm076 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_AND _LD_OPERATOR : 3 _LD_CONTACT gBlenderCIPMode _EXPRESSION _POSITIV _LD_CONTACT gBlenderRun_Latch _EXPRESSION _POSITIV _LD_CONTACT gInCIP_Fault _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm090 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm090 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gManualWaterDrainValve _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm120 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm120 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gManualSyrupDrainValve _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm121 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm121 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gSyrupLineNotSelected _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm122 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm122 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gInManifoldNotReadyForProd _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm130 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm130 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 2 _LD_CONTACT gInManifoldNotReadyForCIP _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gH_Alarm131 _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _NEGATIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 2 _OUTPUT _POSITIV _NO_SET gH_Alarm131 _OUTPUT _POSITIV _SET gBlenderAlarm _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 3 _LD_CONTACT DI_Reset_Horn_Btn _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gBlenderAlarm _EXPRESSION _POSITIV _LD_CONTACT mAlarmHornReset _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET mAlarmHornReset _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_AND _LD_OPERATOR : 3 _LD_CONTACT gBlenderAlarm _EXPRESSION _POSITIV _LD_CONTACT mAlarmHornReset _EXPRESSION _NEGATIV _FUNCTIONBLOCK mAlarmHornActive _BOX_EXPR : 2 _EMPTY _OPERAND _EXPRESSION _POSITIV mAlarmHornReset _EXPRESSION _POSITIV SR _OUTPUTS : 0 _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET gAlarmHorn _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_OR _LD_OPERATOR : 3 _LD_CONTACT DI_Reset_Horn_Btn _EXPRESSION _POSITIV _LD_AND _LD_OPERATOR : 2 _LD_CONTACT gBlenderAlarm _EXPRESSION _POSITIV _LD_CONTACT mWarningHornReset _EXPRESSION _POSITIV _EXPRESSION _POSITIV _LD_CONTACT DI_Reset_Btn _EXPRESSION _POSITIV _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET mWarningHornReset _NETWORK _COMMENT _END_COMMENT _LD_ASSIGN _LD_AND _LD_OPERATOR : 3 _LD_CONTACT gBlenderAlarm _EXPRESSION _POSITIV _LD_CONTACT mWarningHornReset _EXPRESSION _NEGATIV _FUNCTIONBLOCK mWarningHornActive _BOX_EXPR : 2 _EMPTY _OPERAND _EXPRESSION _POSITIV mWarningHornReset _EXPRESSION _POSITIV SR _OUTPUTS : 0 _EXPRESSION _POSITIV _EXPRESSION _POSITIV ENABLELIST : 0 ENABLELIST_END _OUTPUTS : 1 _OUTPUT _POSITIV _NO_SET gWarningHorn END_PROGRAM