--- Log de Ejecución: x2.py ---
|
|
Grupo: ObtainIOFromProjectTia
|
|
Directorio de Trabajo: C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport
|
|
Inicio: 2025-05-12 13:33:41
|
|
Fin: 2025-05-12 13:36:50
|
|
Duración: 0:03:09.036254
|
|
Estado: SUCCESS (Código de Salida: 0)
|
|
|
|
--- SALIDA ESTÁNDAR (STDOUT) ---
|
|
--- TIA Portal Project CAx Exporter and Analyzer ---
|
|
|
|
Selected Project: C:/Trabajo/SIDEL/06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)/InLavoro/PLC/_NEW/SAE196_c0.2/SAE196_c0.2.ap18
|
|
Using Output Directory (Working Directory): C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport
|
|
Will export CAx data to: C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport\SAE196_c0.2_CAx_Export.aml
|
|
Will generate summary to: C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport\SAE196_c0.2_CAx_Summary.md
|
|
Export log file: C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport\SAE196_c0.2_CAx_Export.log
|
|
|
|
Connecting to TIA Portal V18.0...
|
|
2025-05-12 13:34:08,368 [1] INFO Siemens.TiaPortal.OpennessApi18.Implementations.Global OpenPortal - Start TIA Portal, please acknowledge the security dialog.
|
|
2025-05-12 13:34:08,393 [1] INFO Siemens.TiaPortal.OpennessApi18.Implementations.Global OpenPortal - With user interface
|
|
Connected.
|
|
Opening project: SAE196_c0.2.ap18...
|
|
2025-05-12 13:34:56,050 [1] INFO Siemens.TiaPortal.OpennessApi18.Implementations.Portal OpenProject - Open project... C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\InLavoro\PLC\_NEW\SAE196_c0.2\SAE196_c0.2.ap18
|
|
Project opened.
|
|
Exporting CAx data for the project to C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport\SAE196_c0.2_CAx_Export.aml...
|
|
CAx data exported successfully.
|
|
|
|
Closing TIA Portal...
|
|
2025-05-12 13:36:46,602 [1] INFO Siemens.TiaPortal.OpennessApi18.Implementations.Portal ClosePortal - Close TIA Portal
|
|
TIA Portal closed.
|
|
Parsing AML file: C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport\SAE196_c0.2_CAx_Export.aml
|
|
Markdown summary written to: C:\Trabajo\SIDEL\06 - E5.007363 - Modifica O&U - SAE196 (cip integrato)\Reporte\IOExport\SAE196_c0.2_CAx_Summary.md
|
|
|
|
Script finished.
|
|
|
|
--- ERRORES (STDERR) ---
|
|
Ninguno
|
|