(* @GLOBAL_VARIABLE_LIST := HMI_Alarms *)
|
|
(* @PATH := '\/HMI_Variable' *)
|
|
(* @SYMFILEFLAGS := '59392' *)
|
|
VAR_GLOBAL
|
|
(**********************************************************************************************************************)
|
|
(* FAULT ALARMS *)
|
|
(**********************************************************************************************************************)
|
|
gH_Alarm001 :BOOL; (* Auxiliary Not Engaged *)
|
|
gH_Alarm002 :BOOL; (* Not a Recipe: invalid Recipe Type Selection *)
|
|
gH_Alarm003 :BOOL; (* Error during Densimeter Calibration *)
|
|
gH_Alarm004 :BOOL; (* Filler Communication Fault *)
|
|
gH_Alarm005 :BOOL; (* *)
|
|
gH_Alarm006 :BOOL; (* CIP Communication Fault *)
|
|
gH_Alarm007 :BOOL; (* Differential Pressure Transducer Fault *)
|
|
gH_Alarm008 :BOOL; (* Syrup tank flooded *)
|
|
gH_Alarm009 :BOOL; (* *)
|
|
gH_Alarm010 :BOOL; (* Profibus Valves Base Node12 Fault *)
|
|
gH_Alarm011 :BOOL; (* Profibus Valves Base Node13 Fault *)
|
|
gH_Alarm012 :BOOL; (* Profibus Low Conductimeter Node 15 Fault *)
|
|
gH_Alarm013 :BOOL; (* Profibus High Conductimeter Node 16 Fault *)
|
|
gH_Alarm014 :BOOL; (* Pressure Control Valve Position Fault *)
|
|
gH_Alarm015 :BOOL; (* Deareation Control Valve Position Fault *)
|
|
gH_Alarm016 :BOOL; (* Water Inlet Valve EV73 Position Fault *)
|
|
gH_Alarm017 :BOOL; (* CIP Inlet Valve EV74 Position Fault *)
|
|
gH_Alarm018 :BOOL; (* Product Outlet Valve EV62 Position Fault *)
|
|
gH_Alarm019 :BOOL; (* Filler Pressure Valve EV46 Position Fault *)
|
|
gH_Alarm020 :BOOL; (* Product Brix Too High *)
|
|
gH_Alarm021 :BOOL; (* Product Brix Too Low *)
|
|
gH_Alarm022 :BOOL; (* Product CO2 Too High *)
|
|
gH_Alarm023 :BOOL; (* Product CO2 Too Low *)
|
|
gH_Alarm024 :BOOL; (* *)
|
|
gH_Alarm025 :BOOL; (* Product Pump P3 VFC Fault - Fault Alarm *)
|
|
gH_Alarm026 :BOOL; (* ByPass Pump P6 Fault - Fault Alarm *)
|
|
gH_Alarm027 :BOOL; (* mPDS1000 Error Fault *)
|
|
gH_Alarm028 :BOOL; (* Densimeter Tubes Not Oscillating *)
|
|
gH_Alarm029 :BOOL; (* Water Pump P5 Fault - Fault Alarm - *)
|
|
gH_Alarm030 :BOOL; (* Water Pump P1 Fault - Fault Alarm - *)
|
|
gH_Alarm031 :BOOL; (* Syrup Pump P2 Fault - Fault Alarm - *)
|
|
gH_Alarm032 :BOOL; (* Product Pump P3 Fault - Fault Alarm - *)
|
|
gH_Alarm033 :BOOL; (* Vacuum Pump P4 Fault - Fault Alarm - *)
|
|
gH_Alarm034 :BOOL; (* Tank Rinse Pump P5 Fault - Fault Alarm - *)
|
|
gH_Alarm035 :BOOL; (* Water FlowMeter General Fault - Fault Alarm - *)
|
|
gH_Alarm036 :BOOL; (* Syrup FlowMeter General Fault - Fault Alarm - *)
|
|
gH_Alarm037 :BOOL; (* Carbo CO2 FlowMeter Fault - Fault Alarm - *)
|
|
gH_Alarm038 :BOOL; (* Water Control Valve Position Fault - Fault Alarm - *)
|
|
gH_Alarm039 :BOOL; (* Syrup Control Valve Position Fault - Fault Alarm - *)
|
|
gH_Alarm040 :BOOL; (* Carbo CO2 Control Valve Position Fault - Fault Alarm - *)
|
|
gH_Alarm041 :BOOL; (* Product Tank Pressure Fault - Fault Alarm - *)
|
|
gH_Alarm042 :BOOL; (* Blend Error Fault: High Syrup - Fault Alarm - *)
|
|
gH_Alarm043 :BOOL; (* Blend Error Fault: Low Syrup - Fault Alarm - *)
|
|
gH_Alarm044 :BOOL; (* CarboCO2 Error Fault: Low CO2 - Fault Alarm - *)
|
|
gH_Alarm045 :BOOL; (* CarboCO2 Error Fault: High CO2 - Fault Alarm - *)
|
|
gH_Alarm046 :BOOL; (* Vacuum TimeOut - Fault Alarm - *)
|
|
gH_Alarm047 :BOOL; (* CIP Transfer Time Out - Fault Alarm - *)
|
|
gH_Alarm048 :BOOL; (* CIP No Recirculation Flow - Fault Alarm - *)
|
|
gH_Alarm049 :BOOL; (* *)
|
|
gH_Alarm050 :BOOL; (* Profibus Master Node 1 Crash *)
|
|
gH_Alarm051 :BOOL; (* Profibus ET200 Node 10 Fault *)
|
|
gH_Alarm052 :BOOL; (* Profibus Water MFM Node 20 Fault *)
|
|
gH_Alarm053 :BOOL; (* Profibus Syrup MFM Node 21 Fault *)
|
|
gH_Alarm054 :BOOL; (* Profibus CO2 MFM Node 22 Fault *)
|
|
gH_Alarm055 :BOOL; (* Profibus Product Pump VFC Node Fault *)
|
|
gH_Alarm056 :BOOL; (* *)
|
|
gH_Alarm057 :BOOL; (* UPS Battery not ready - NON FERMA LA MACHINA *)
|
|
gH_Alarm058 :BOOL; (* Profibus Adapter mPDS Error Fault *)
|
|
gH_Alarm059 :BOOL; (* mPDS2000 Error Fault *)
|
|
(*********************************************************************************************************************)
|
|
(* SUPPLIES ALARMS *)
|
|
(*********************************************************************************************************************)
|
|
gH_Alarm060 :BOOL; (* Low Infeed Air Pressure Fault - Supplies Alarm - *)
|
|
gH_Alarm061 :BOOL; (* Low Infeed CO2 Pressure Fault - Supplies Alarm - *)
|
|
gH_Alarm062 :BOOL; (* Deaireator Water Low Level - Supplies Alarm - *)
|
|
gH_Alarm063 :BOOL; (* Syrup Tank Low Level - Supplies Alarm - *)
|
|
gH_Alarm064 :BOOL; (* Syrup Room Pump Fault - Supplies Alarm - *)
|
|
gH_Alarm065 :BOOL; (* Syrup Brix Out Of Standard - Supplies Alarm - *)
|
|
gH_Alarm066 :BOOL; (* Chiller Ammonia Pressure Too Low - Supplies Alarm - *)
|
|
gH_Alarm067 :BOOL; (* Water Temperature Too High *)
|
|
gH_Alarm068 :BOOL; (* Product Temperature Too High *)
|
|
gH_Alarm069 :BOOL; (* Syrup Room Water Pump Fault - Supplie Alarm - *)
|
|
gH_Alarm070 :BOOL; (* Syrup Density Out Of Standard - Supplies Alarm - *)
|
|
gH_Alarm071 :BOOL; (* *)
|
|
gH_Alarm072 :BOOL; (* Ammonia compressors not running - Supplies Alarm *)
|
|
gH_Alarm073 :BOOL; (* *)
|
|
gH_Alarm074 :BOOL; (* *)
|
|
gH_Alarm075 :BOOL; (* *)
|
|
gH_Alarm076 :BOOL; (* *)
|
|
gH_Alarm077 :BOOL; (* *)
|
|
gH_Alarm078 :BOOL; (* *)
|
|
gH_Alarm079 :BOOL; (* *)
|
|
gH_Alarm080 :BOOL; (* *)
|
|
gH_Alarm081 :BOOL; (* *)
|
|
gH_Alarm082 :BOOL; (* *)
|
|
gH_Alarm083 :BOOL; (* *)
|
|
gH_Alarm084 :BOOL; (* *)
|
|
gH_Alarm085 :BOOL; (* *)
|
|
gH_Alarm086 :BOOL; (* *)
|
|
gH_Alarm087 :BOOL; (* *)
|
|
gH_Alarm088 :BOOL; (* *)
|
|
gH_Alarm089 :BOOL; (* *)
|
|
(**********************************************************************************************************************)
|
|
(* EXTERNAL ALARMS *)
|
|
(**********************************************************************************************************************)
|
|
gH_Alarm090 :BOOL; (* CIP Fault *)
|
|
gH_Alarm091 :BOOL; (* *)
|
|
gH_Alarm092 :BOOL; (* *)
|
|
gH_Alarm093 :BOOL; (* *)
|
|
gH_Alarm094 :BOOL; (* *)
|
|
gH_Alarm095 :BOOL; (* *)
|
|
gH_Alarm096 :BOOL; (* *)
|
|
gH_Alarm097 :BOOL; (* *)
|
|
gH_Alarm098 :BOOL; (* *)
|
|
gH_Alarm099 :BOOL; (* *)
|
|
gH_Alarm100 :BOOL; (* *)
|
|
gH_Alarm101 :BOOL; (* *)
|
|
gH_Alarm102 :BOOL; (* *)
|
|
gH_Alarm103 :BOOL; (* *)
|
|
gH_Alarm104 :BOOL; (* *)
|
|
gH_Alarm105 :BOOL; (* *)
|
|
gH_Alarm106 :BOOL; (* *)
|
|
gH_Alarm107 :BOOL; (* *)
|
|
gH_Alarm108 :BOOL; (* *)
|
|
gH_Alarm109 :BOOL; (* *)
|
|
gH_Alarm110 :BOOL; (* *)
|
|
gH_Alarm111 :BOOL; (* *)
|
|
gH_Alarm112 :BOOL; (* *)
|
|
gH_Alarm113 :BOOL; (* *)
|
|
gH_Alarm114 :BOOL; (* *)
|
|
gH_Alarm115 :BOOL; (* *)
|
|
gH_Alarm116 :BOOL; (* *)
|
|
gH_Alarm117 :BOOL; (* *)
|
|
gH_Alarm118 :BOOL; (* *)
|
|
gH_Alarm119 :BOOL; (* *)
|
|
(**********************************************************************************************************************)
|
|
(* OPERATOR ALARMS *)
|
|
(**********************************************************************************************************************)
|
|
gH_Alarm120 :BOOL; (* Water Manual Valve Open *)
|
|
gH_Alarm121 :BOOL; (* Syrup Line Manual Drain Valve Open *)
|
|
gH_Alarm122 :BOOL; (* Syrup Line Not Selected *)
|
|
gH_Alarm123 :BOOL; (* *)
|
|
gH_Alarm124 :BOOL; (* *)
|
|
gH_Alarm125 :BOOL; (* *)
|
|
gH_Alarm126 :BOOL; (* *)
|
|
gH_Alarm127 :BOOL; (* *)
|
|
gH_Alarm128 :BOOL; (* *)
|
|
gH_Alarm129 :BOOL; (* *)
|
|
gH_Alarm130 :BOOL; (* Manifold not ready for Prod *)
|
|
gH_Alarm131 :BOOL; (* Manifold not ready for CIP *)
|
|
gH_Alarm132 :BOOL; (* *)
|
|
gH_Alarm133 :BOOL; (* *)
|
|
gH_Alarm134 :BOOL; (* *)
|
|
gH_Alarm135 :BOOL; (* *)
|
|
gH_Alarm136 :BOOL; (* *)
|
|
gH_Alarm137 :BOOL; (* *)
|
|
gH_Alarm138 :BOOL; (* *)
|
|
gH_Alarm139 :BOOL; (* *)
|
|
gH_Alarm140 :BOOL; (* *)
|
|
gH_Alarm141 :BOOL; (* *)
|
|
gH_Alarm142 :BOOL; (* *)
|
|
gH_Alarm143 :BOOL; (* *)
|
|
gH_Alarm144 :BOOL; (* *)
|
|
gH_Alarm145 :BOOL; (* *)
|
|
gH_Alarm146 :BOOL; (* *)
|
|
gH_Alarm147 :BOOL; (* *)
|
|
gH_Alarm148 :BOOL; (* *)
|
|
gH_Alarm149 :BOOL; (* *)
|
|
gH_Alarm150 :BOOL; (* *)
|
|
END_VAR
|
|
|
|
VAR_GLOBAL
|
|
gH_Message000 AT%MB300:BOOL; (* *)
|
|
gH_Message001 AT%MB301:BOOL; (* *)
|
|
gH_Message002 AT%MB302:BOOL; (* *)
|
|
gH_Message003 AT%MB303:BOOL; (* Manual Activated *)
|
|
gH_Message004 AT%MB304:BOOL; (* *)
|
|
gH_Message005 AT%MB305:BOOL; (* *)
|
|
gH_Message006 AT%MB306:BOOL; (* *)
|
|
gH_Message007 AT%MB307:BOOL; (* *)
|
|
gH_Message008 AT%MB308:BOOL; (* Opeartor Run Syrup Prep *)
|
|
gH_Message009 AT%MB309:BOOL; (* Operator Start Deaireator *)
|
|
gH_Message010 AT%MB310:BOOL; (* *)
|
|
gH_Message011 AT%MB311:BOOL; (* *)
|
|
gH_Message012 AT%MB312:BOOL; (* Water Flow Too Low *)
|
|
gH_Message013 AT%MB313:BOOL; (* Water Stream Critical Speed *)
|
|
gH_Message014 AT%MB314:BOOL; (* *)
|
|
gH_Message015 AT%MB315:BOOL; (* *)
|
|
gH_Message016 AT%MB316:BOOL; (* *)
|
|
gH_Message017 AT%MB317:BOOL; (* CO2 inlet line pressure not stable *)
|
|
gH_Message018 AT%MB318:BOOL; (* Product Brix Low *)
|
|
gH_Message019 AT%MB319:BOOL; (* Product Brix High *)
|
|
gH_Message020 AT%MB320:BOOL; (* Product CO2 Vol Low *)
|
|
gH_Message021 AT%MB321:BOOL; (* Product CO2 Vol High *)
|
|
gH_Message022 AT%MB322:BOOL; (* *)
|
|
gH_Message023 AT%MB323:BOOL; (* *)
|
|
gH_Message024 AT%MB324:BOOL; (* *)
|
|
gH_Message025 AT%MB325:BOOL; (* *)
|
|
gH_Message026 AT%MB326:BOOL; (* *)
|
|
gH_Message027 AT%MB327:BOOL; (* Start Maselli pump *)
|
|
gH_Message028 AT%MB328:BOOL; (* Maselli Lamp Failure *)
|
|
gH_Message029 AT%MB329:BOOL; (* *)
|
|
gH_Message030 AT%MB330:BOOL; (* Wait Filler CIP Signal *)
|
|
gH_Message031 AT%MB331:BOOL; (* Wait Filler Product Request Signal *)
|
|
gH_Message032 AT%MB332:BOOL; (* Wait Filler Rinse Completed Signal *)
|
|
gH_Message033 AT%MB333:BOOL; (* Local CIP Wait Temperature *)
|
|
gH_Message034 AT%MB334:BOOL; (* Local CIP Wait High Conductivity *)
|
|
gH_Message035 AT%MB335:BOOL; (* Local CIP Wait Low Conductivity *)
|
|
gH_Message036 AT%MB336:BOOL; (* Local CIP Wait Drain Completed *)
|
|
gH_Message037 AT%MB337:BOOL; (* Local CIP Wait CIP cycle ended *)
|
|
gH_Message038 AT%MB338:BOOL; (* Local CIP Wait Change ready *)
|
|
gH_Message039 AT%MB339:BOOL; (* *)
|
|
gH_Message040 AT%MB340:BOOL; (* *)
|
|
gH_Message041 AT%MB341:BOOL; (* *)
|
|
gH_Message042 AT%MB342:BOOL; (* *)
|
|
gH_Message043 AT%MB343:BOOL; (* *)
|
|
gH_Message044 AT%MB344:BOOL; (* *)
|
|
gH_Message045 AT%MB345:BOOL; (* *)
|
|
gH_Message046 AT%MB346:BOOL; (* *)
|
|
gH_Message047 AT%MB347:BOOL; (* *)
|
|
gH_Message048 AT%MB348:BOOL; (* *)
|
|
gH_Message049 AT%MB349:BOOL; (* *)
|
|
gH_Message050 AT%MB350:BOOL; (* Chiler Ammonia level too high *)
|
|
gH_Message051 AT%MB351:BOOL; (* Product near to freezing temperature *)
|
|
gH_Message052 AT%MB352:BOOL; (* Product temperature too high *)
|
|
gH_Message053 AT%MB353:BOOL; (* Water near to freezing temperature *)
|
|
gH_Message054 AT%MB354:BOOL; (* Water temperature to high *)
|
|
gH_Message055 AT%MB355:BOOL; (* Check Oil in Modulating Valve *)
|
|
gH_Message056 AT%MB356:BOOL; (* Check Oil in water pump motor *)
|
|
gH_Message057 AT%MB357:BOOL; (* Profibus Product PH Node 18 Fault *)
|
|
gH_Message058 AT%MB358:BOOL; (* Profibus Product ConductiveMeter Node 19 Fault *)
|
|
gH_Message059 AT%MB359:BOOL; (* Product High Conductivity *)
|
|
gH_Message060 AT%MB360:BOOL; (* Product Low Conductivity *)
|
|
gH_Message061 AT%MB361:BOOL; (* Blend Fill System Start Up To Do *)
|
|
gH_Message062 AT%MB362:BOOL; (* Wait filler ready to start up *)
|
|
gH_Message063 AT%MB363:BOOL; (* Wait filler flushing completed *)
|
|
gH_Message064 AT%MB364:BOOL; (* Wait filler loading completed *)
|
|
gH_Message065 AT%MB365:BOOL; (* Profibus Product VFM Node 17 Fault *)
|
|
gH_Message066 AT%MB366:BOOL; (* *)
|
|
gH_Message067 AT%MB367:BOOL; (* *)
|
|
gH_Message068 AT%MB368:BOOL; (* *)
|
|
gH_Message069 AT%MB369:BOOL; (* *)
|
|
gH_Message070 AT%MB370:BOOL; (* *)
|
|
|
|
gH_Status000 AT%MB600:BOOL; (* *)
|
|
gH_Status001 AT%MB601:BOOL; (* Waiting Product Tank Pressure *)
|
|
gH_Status002 AT%MB602:BOOL; (* Start Up Deaireator Running *)
|
|
gH_Status003 AT%MB603:BOOL; (* Syrup Prep Running *)
|
|
gH_Status004 AT%MB604:BOOL; (* Syrup Autocorrection Running *)
|
|
gH_Status005 AT%MB605:BOOL; (* Syrup Run Out Running *)
|
|
gH_Status006 AT%MB606:BOOL; (* First Product Running *)
|
|
gH_Status007 AT%MB607:BOOL; (* Waiting Vacuum *)
|
|
gH_Status008 AT%MB608:BOOL; (* Max Syrup Brix Autocorrection Acheaved - NOT USED*)
|
|
gH_Status009 AT%MB609:BOOL; (* Product Brix Tracking Hold *)
|
|
gH_Status010 AT%MB610:BOOL; (* Product Brix Tracking *)
|
|
gH_Status011 AT%MB611:BOOL; (* Product CO2 Tracking *)
|
|
gH_Status012 AT%MB600:BOOL; (* *)
|
|
gH_Status013 AT%MB600:BOOL; (* *)
|
|
gH_Status014 AT%MB614:BOOL; (* Warm Rinse Running *)
|
|
gH_Status015 AT%MB615:BOOL; (* Cold Rinse Running *)
|
|
gH_Status016 AT%MB616:BOOL; (* *)
|
|
gH_Status017 AT%MB617:BOOL; (* *)
|
|
gH_Status018 AT%MB618:BOOL; (* *)
|
|
gH_Status019 AT%MB619:BOOL; (* *)
|
|
gH_Status020 AT%MB620:BOOL; (* *)
|
|
gH_Status021 AT%MB621:BOOL; (* *)
|
|
gH_Status022 AT%MB622:BOOL; (* CIP Drain Activated *)
|
|
gH_Status023 AT%MB623:BOOL; (* Water Line Carbonating Running *)
|
|
gH_Status024 AT%MB624:BOOL; (* *)
|
|
gH_Status025 AT%MB625:BOOL; (* Product Tank Drain Active *)
|
|
gH_Status026 AT%MB626:BOOL; (* Rinse Drain Active *)
|
|
gH_Status027 AT%MB627:BOOL; (* *)
|
|
gH_Status028 AT%MB628:BOOL; (* *)
|
|
gH_Status029 AT%MB629:BOOL; (* *)
|
|
gH_Status030 AT%MB630:BOOL; (* *)
|
|
gH_Status031 AT%MB631:BOOL; (* *)
|
|
gH_Status032 AT%MB632:BOOL; (* *)
|
|
gH_Status033 AT%MB633:BOOL; (* *)
|
|
gH_Status034 AT%MB634:BOOL; (* *)
|
|
gH_Status035 AT%MB635:BOOL; (* *)
|
|
gH_Status036 AT%MB636:BOOL; (* *)
|
|
gH_Status037 AT%MB637:BOOL; (* Local CIP Hold *)
|
|
gH_Status038 AT%MB638:BOOL; (* Local CIP Completed *)
|
|
gH_Status039 AT%MB639:BOOL; (* System Run Out Running *)
|
|
gH_Status040 AT%MB640:BOOL; (* *)
|
|
gH_Status041 AT%MB641:BOOL; (* *)
|
|
gH_Status042 AT%MB642:BOOL; (* *)
|
|
gH_Status043 AT%MB643:BOOL; (* *)
|
|
gH_Status044 AT%MB644:BOOL; (* Product Tank Run Out Running *)
|
|
gH_Status045 AT%MB645:BOOL; (* Product Pipe Run Out Running *)
|
|
gH_Status046 AT%MB646:BOOL; (* *)
|
|
gH_Status047 AT%MB647:BOOL; (* Product Pipe Draining *)
|
|
gH_Status048 AT%MB648:BOOL; (* Filler Rinse Running *)
|
|
gH_Status049 AT%MB649:BOOL; (* *)
|
|
gH_Status050 AT%MB650:BOOL; (* *)
|
|
gH_Status051 AT%MB651:BOOL; (* *)
|
|
gH_Status052 AT%MB652:BOOL; (* *)
|
|
gH_Status053 AT%MB653:BOOL; (* *)
|
|
gH_Status054 AT%MB654:BOOL; (* *)
|
|
gH_Status055 AT%MB655:BOOL; (* *)
|
|
gH_Status056 AT%MB656:BOOL; (* *)
|
|
gH_Status057 AT%MB657:BOOL; (* *)
|
|
gH_Status058 AT%MB658:BOOL; (* *)
|
|
gH_Status059 AT%MB659:BOOL; (* *)
|
|
gH_Status060 AT%MB660:BOOL; (* *)
|
|
gH_Status061 AT%MB661:BOOL; (* Blend Fill System Buffer Tank Loading *)
|
|
gH_Status062 AT%MB662:BOOL; (* Blend Fill System Pressurization Running *)
|
|
gH_Status063 AT%MB663:BOOL; (* Blend Fill System Product Filler Load *)
|
|
gH_Status064 AT%MB664:BOOL; (* Blend Fill System Product Filler Send *)
|
|
END_VAR
|
|
|
|
VAR_GLOBAL
|
|
gH_Message AT %MB300 : ARRAY [0..70] OF BOOL;
|
|
gH_Message_code :INT;
|
|
|
|
gH_Status AT %MB600 : ARRAY [0..70] OF BOOL;
|
|
gH_Status_code : INT ;
|
|
END_VAR
|
|
(* @OBJECT_END := HMI_Alarms *)
|
|