// Block Name (Original): BlenderCtrl__Main // Block Number: 2000 // Original Language: LAD FUNCTION_BLOCK "BlenderCtrl__Main" { S7_Optimized_Access := 'TRUE' } VERSION : 0.1 VAR_RETURN Ret_Val : Void; END_VAR VAR_TEMP All_Auto_RETVAL : Int; Reset_SP_Word_RETVAL : Int; mResetWaterTot : Bool; mResetSyrupTot : Bool; mResetCO2Tot : Bool; mResetProductTot : Bool; Block_Move_Err : Int; END_VAR BEGIN // Network 1: Clock Generation (Original Language: LAD) Clock_Signal(); // Network 2: Machine Init (Original Language: LAD) BlenderCtrl_MachineInit(); // Network 3: Filler Head (Original Language: LAD) IF "AUX FALSE" THEN "Block_Move_Err" := BLKMOV(SRCBLK := "HMI_PID"."PPM303", DSTBLK => "Filler_Head_Variables"."FillerHead"); // ADVERTENCIA: BLKMOV usado directamente, probablemente no compile! END_IF; // Network 4: Emergency Pressed (Original Language: LAD) "gEmergencyPressed" := "M19000" AND NOT "gIN_VoltageOk"; "M19000" := "gIN_VoltageOk"; // N_TRIG("gIN_VoltageOk") - Mem: "M19000" // Network 5: Air and CO2 pressure ok and auxiliary ok (Original Language: LAD) "gBlenderSuppliesOk" := ("gIN_VoltageOk" AND "gIN_LinePressCO2Ok" AND "HMI_Digital"."_PAL_S11"."Filtered") OR ("gIN_VoltageOk" AND "gIN_LinePressCO2Ok" AND NOT "Disable_Bit") OR ("gIN_VoltageOk" AND "gWorkshopTest" AND "HMI_Digital"."_PAL_S11"."Filtered" AND NOT "gWorkshop_Co2_Presence" AND NOT "gWorkshop_CIP_Signals") OR ("gIN_VoltageOk" AND "gWorkshopTest" AND NOT "gWorkshop_Co2_Presence" AND NOT "gWorkshop_CIP_Signals" AND NOT "Disable_Bit"); // Network 6: Blender State Num (Original Language: LAD) "HMI_Variables_Status"."Procedures"."BlenderStateNum" := 0; // Network 7: Delay Power On (Original Language: LAD) "mDelayPowerOnTmr"(IN := "FirstScan", PT := S5T#2S); // TODO: Declarar "mDelayPowerOnTmr" : TP; // Network 8: Production Mode (Original Language: LAD) "gBlenderProdMode" := "HMI_Variables_Status"."System"."Blender_Prod_CIP"; // Network 9: CIp Mode (Original Language: LAD) "gBlenderCIPMode" := NOT "HMI_Variables_Status"."System"."Blender_Prod_CIP"; IF NOT "HMI_Variables_Status"."System"."Blender_Prod_CIP" THEN "HMI_Variables_Status"."Procedures"."BlenderStateNum" := 19; END_IF; // Network 10: Error Faults (Original Language: LAD) IF NOT "AUX FALSE" THEN "HMI_Variables_Status"."Meters"."QTM3012_PRD_Fault" := FALSE; END_IF; IF NOT "AUX FALSE" THEN "gmPDS2000_Error_Fault" := FALSE; END_IF; IF NOT "AUX FALSE" THEN "HMI_Variables_Status"."Meters"."QTM3012_PRD_Run" := FALSE; END_IF; IF NOT "AUX FALSE" THEN "gNoFreezeProductMeter" := FALSE; END_IF; // Network 11: Filler Bottle Count Used to push Product (Original Language: LAD) "System_RunOut_Variables"."ProdPipeRunOutFillerBott" := NOT "System_RunOut_Variables"."ProdPipeRunOutWaterCount"; // Network 12: Water Bypass Enable (Original Language: LAD) "gStillWaterByPassEn" := ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_StillWaterByPass" AND "Blender_Variables_Pers"."gWaterRecipe" AND NOT "Blender_Variables_Pers"."gCarboStillRecipe") OR ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_ByPassDeair" AND "Blender_Variables_Pers"."gWaterRecipe" AND NOT "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Deaireation" AND NOT "Blender_Variables_Pers"."gCarboStillRecipe"); // Network 13: Still Water Bypass (Original Language: LAD) "gBlendFiStillWaterByPass" := "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_StillWaterByPass" AND "Blender_Variables_Pers"."gWaterRecipe" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_BlendFillSystem" AND NOT "Blender_Variables_Pers"."gCarboStillRecipe"; // Network 14: Manual Syrup Drain Valve Open - Operator Alarm (Original Language: LAD) "gHVP301_Open" := ("gSyrupRoomEn" AND "gBlenderCIPMode" AND "gIN_CIP_CIPRunning" AND "Procedure_Variables"."Blender_Run"."Running" AND NOT "gIN_HVP301_Aux") OR ("gSyrupRoomEn" AND "Procedure_Variables"."FTP302Line_Preparation"."Done" AND NOT "gIN_HVP301_Aux" AND NOT "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_FastChangeOverEnabled" AND NOT "Procedure_Variables"."Syr_RunOut"."Done"); // Network 15: Manual Syrup Drain Valve Open - Operator Alarm (Original Language: LAD) "mHVM302_Dly"(IN := "gIN_HVM302_Aux", PT := S5T#1S); // TODO: Declarar "mHVM302_Dly" : TON; "gHVM302_Open" := "mHVM302_Dly".Q; // Network 16: Maselli Control (Original Language: LAD) IF Eq("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_MeterType", 6) THEN Maselli_PA_Control(); END_IF; // Network 17: mPDS Control (Original Language: LAD) IF Eq("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_MeterType", 5) THEN mPDS_PA_Control(); END_IF; // Network 18: mPDS Syrup Control (Original Language: LAD) IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_SyrBrixMeter" THEN mPDS_SYR_PA_Control(); END_IF; // Network 19: Co2 Analog Input (Original Language: LAD) // GetProdBrixCO2_FromAnalogIn // CALL "GetProdBrixCO2_FromAn" // NOP 0 IF Eq("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_MeterType", 3) THEN GetProdBrixCO2_Anal_Inpt(); END_IF; // Network 20: Quality (Original Language: LAD) ProductQuality(); // Network 21: Input Data (Original Language: LAD) "Input_Data"(); // Network 22: Sel Brix Source Check (Original Language: LAD) SelCheckBrixSource(); // Network 23: Check Water Cooling System Temperature (Original Language: LAD) IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_InverterRecirPumpPPM306" THEN CTRLCoolingSystem(); END_IF; // Network 24: Tank Level (Original Language: LAD) TankLevel(); // Network 25: Production ONS (Original Language: LAD) "gProductionONS" := "gBlenderProdMode" AND NOT "mDelayPowerOnTmr" AND NOT "M19001"; // Network 26: Blender Prod Mode Init (Original Language: LAD) IF ("gProductionONS" AND NOT "Blender_Variables_Pers"."gBlenderStarted") OR ("Procedure_Variables"."Blender_Rinse"."ONS_Done" AND NOT "Blender_Variables_Pers"."gBlenderStarted") THEN BlenderCtrl_ProdModeInit(); END_IF; // Network 27: Rinse ONS (Original Language: LAD) "gRinseONS" := "HMI_Variables_Status"."System"."Blender_Prod_CIP" AND NOT "mDelayPowerOnTmr" AND NOT "M19002"; // Network 28: CIP ONS (Original Language: LAD) "gCIPONS" := "gBlenderCIPMode" AND NOT "mDelayPowerOnTmr" AND NOT "M19003"; // Network 29: CIp Mode Init (Original Language: LAD) IF "gCIPONS" THEN BlenderCtrl_CIPModeInit(); END_IF; // Network 30: Reset SPWords (Original Language: LAD) BlenderCtrl_ResetSPWord(); // Network 31: Blender Run Control (Original Language: LAD) BlenderRun__Control(); // Network 32: Tank Pressure Control (Original Language: LAD) Prod_Tank_PressCtrl(); // Network 33: Balaiage (Original Language: LAD) Baialage(); // Network 34: First Production (Original Language: LAD) "FirstProduction_Data"(); // Network 35: CIP MAIN Calling (Original Language: LAD) CIPMain(); // Network 36: Blender Rinse (Original Language: LAD) BlenderRinse(); // Network 37: Safeties (Original Language: LAD) Safeties(); // Network 38: Instrument Scanner (Original Language: LAD) Instrument_Scanner(); // Network 39: Vacuum Control (Original Language: LAD) VacuumCtrl(); // Network 40: Syrup Room Control (Original Language: LAD) SyrupRoomCtrl(); // Network 41: Blend Procedure Data (Original Language: LAD) IF NOT "mDelayPowerOnTmr" THEN "Blender_Procedure Data"(); END_IF; // Network 42: Pneumatic Valve Control (Original Language: LAD) Pneumatic_Valve_Ctrl(); // Network 43: Pumps Control (Original Language: LAD) PumpsControl(); // Network 44: Prod Report Manager (Original Language: LAD) IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Report" THEN ProdReportManager(); END_IF; // Network 45: Outputs (Original Language: LAD) Output(); // Network 46: SLIM BLOCK (Original Language: LAD) SLIM_Block(); // Network 47: Interlocking Panel 1 (Original Language: LAD) Interlocking_Panel_1(); // Network 48: Filler Control (Original Language: LAD) FillerControl(); // Network 49: Blender Ctrl Update PWORD (Original Language: LAD) BlenderCtrl_UpdatePWord(); // Network 50: ResetTotalizer (Original Language: LAD) "mResetTotalizerTmr"(IN := "gBlendResetTotalizer", PT := S5T#2S); // TODO: Declarar "mResetTotalizerTmr" : TP; // Network 51: ResetWaterTot (Original Language: LAD) "mResetFTN301TotTmr"(IN := "gFTN301_ResetTot" OR "mResetTotalizerTmr", PT := S5T#2S); // TODO: Declarar "mResetFTN301TotTmr" : TP; "mResetWaterTot" := "mResetFTN301TotTmr".Q; // Network 52: Water VFM Reset Totalizer (Original Language: LAD) IF "gFTN301_ResetTot" THEN "gFTN301_ResetTot" := FALSE; END_IF; // Network 53: ResetCO2Tot (Original Language: LAD) "mResetFTP302TotTmr"(IN := "mResetTotalizerTmr" OR "gFTP302_ResetTot", PT := S5T#2S); // TODO: Declarar "mResetFTP302TotTmr" : TP; "mResetSyrupTot" := "gSyrupRoomEn" AND "mResetFTP302TotTmr".Q; // Network 54: Syrup MFM Reset Totalizer (Original Language: LAD) IF "gFTP302_ResetTot" THEN "gFTP302_ResetTot" := FALSE; END_IF; // Network 55: ResetProductTot (Original Language: LAD) "mResetFTM303TotTmr"(IN := "mResetTotalizerTmr" OR "gFTM303_ResetTot", PT := S5T#2S); // TODO: Declarar "mResetFTM303TotTmr" : TP; "mResetCO2Tot" := "mResetFTM303TotTmr".Q; // Network 56: CO2 MFM Reset Tot (Original Language: LAD) IF "gFTM303_ResetTot" THEN "gFTM303_ResetTot" := FALSE; END_IF; // Network 57: ResetCO2Tot (Original Language: LAD) "mResetProductTotTmr"(IN := "mResetTotalizerTmr" OR "gProductMFMResetTot", PT := S5T#2S); // TODO: Declarar "mResetProductTotTmr" : TP; "mResetProductTot" := "mResetProductTotTmr".Q; // Network 58: Reset Totalizer (Original Language: LAD) IF "gProductMFMResetTot" THEN "gProductMFMResetTot" := FALSE; END_IF; // Network 59: Reset Totalizer (Original Language: LAD) IF "gBlendResetTotalizer" THEN "gBlendResetTotalizer" := FALSE; END_IF; // Network 60: Blender Ctrl Command (Original Language: LAD) IF NOT "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Simulation" THEN BlenderCtrl_MFM_Command(); END_IF; // Network 61: DP Global Diag (Original Language: LAD) CPU_DP_Global_Diag(); // Network 62: Profibus (Original Language: LAD) Profibus_Network(); // Network 63: Valve Fault (Original Language: LAD) ModValveFault(); // Network 64: All Auto (Original Language: LAD) IF ("M19011" AND NOT "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Command") OR ("M19011" AND NOT "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Enable") THEN BlenderCtrl_All_Auto(); END_IF; "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Light" := "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Command" AND "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Enable"; // Network 65: Ctrl HMI Manual Active (Original Language: LAD) BlenderCtrl_ManualActive(); // Network 66: Mod Copy Recipe (Original Language: LAD) "mAux_FP_M700_1" := "HMI_Variables_Cmd"."Recipe"."Main_Page" AND NOT "mFP_Recip_Main_Page"; "mFP_Recip_Main_Page" := "HMI_Variables_Cmd"."Recipe"."Main_Page"; "T_Pulse_Recipe_Edit"(IN := "HMI_Variables_Cmd"."Recipe"."Main_Page" AND "HMI_Variables_Cmd"."Recipe"."Edit", PT := S5T#500ms); // TODO: Declarar "T_Pulse_Recipe_Edit" : TP; IF "T_Pulse_Recipe_Edit" AND "T_Pulse_Recipe_Edit".Q THEN "HMI_Variables_Cmd"."Recipe"."Edit" := FALSE; END_IF; IF "mAux_FP_M700_1" THEN "HMI_Variables_Cmd"."Recipe"."Edit" := TRUE; END_IF; // Network 67: to HMI - Recipe Management (Original Language: LAD) IF "AUX TRUE" THEN "RecipeManagement_Data"(); END_IF; // Network 68: Recipe Calculation (Original Language: LAD) RecipeCalculation(); END_FUNCTION_BLOCK