// Block Name (Original): BlenderCtrl__Main
// Block Number: 2000
// Original Language: LAD
FUNCTION_BLOCK "BlenderCtrl__Main"
{ S7_Optimized_Access := 'TRUE' }
VERSION : 0.1
VAR_INPUT
END_VAR
VAR_OUTPUT
END_VAR
VAR_IN_OUT
END_VAR
VAR_TEMP
All_Auto_RETVAL : Int;
Reset_SP_Word_RETVAL : Int;
mResetWaterTot : Bool;
mResetSyrupTot : Bool;
mResetCO2Tot : Bool;
mResetProductTot : Bool;
Block_Move_Err : Int;
END_VAR
BEGIN
// Network 1: Clock Generation (Original Language: LAD)
Clock_Signal();
// Network 2: Machine Init (Original Language: LAD)
BlenderCtrl_MachineInit();
// Network 3: Filler Head (Original Language: LAD)
IF "AUX FALSE" THEN
"Block_Move_Err" := BLKMOV(SRCBLK := "HMI_PID"."PPM303", DSTBLK => "Filler_Head_Variables"."FillerHead"); // ADVERTENCIA: BLKMOV usado directamente, probablemente no compile!
END_IF;
// Network 4: Emergency Pressed (Original Language: LAD)
// Logic moved to Coil 26
"gEmergencyPressed" := NOT "gIN_VoltageOk" AND "M19000";
"M19000" := "gIN_VoltageOk"; // N_TRIG("gIN_VoltageOk")
// Network 5: Air and CO2 pressure ok and auxiliary ok (Original Language: LAD)
"gBlenderSuppliesOk" := (("gIN_LinePressCO2Ok" OR ("gWorkshopTest" AND (NOT "gWorkshop_Co2_Presence")) AND (NOT "gWorkshop_CIP_Signals")) AND "HMI_Digital"."_PAL_S11"."Filtered") OR ("gIN_LinePressCO2Ok" OR ("gWorkshopTest" AND (NOT "gWorkshop_Co2_Presence")) AND (NOT "gWorkshop_CIP_Signals")) AND (NOT "Disable_Bit") AND "gIN_VoltageOk";
// Network 6: Blender State Num (Original Language: LAD)
"HMI_Variables_Status"."Procedures"."BlenderStateNum" := 0;
// Network 7: Delay Power On (Original Language: LAD)
"mDelayPowerOnTmr"(IN := "FirstScan", PT := S5T#2S); // TODO: Declarar "mDelayPowerOnTmr" : TP; en VAR_STAT o VAR
// Network 8: Production Mode (Original Language: LAD)
"gBlenderProdMode" := "HMI_Variables_Status"."System"."Blender_Prod_CIP";
// Network 9: CIp Mode (Original Language: LAD)
"gBlenderCIPMode" := (NOT "HMI_Variables_Status"."System"."Blender_Prod_CIP");
IF (NOT "HMI_Variables_Status"."System"."Blender_Prod_CIP") THEN
"HMI_Variables_Status"."Procedures"."BlenderStateNum" := 19;
END_IF;
// Network 10: Error Faults (Original Language: LAD)
IF (NOT "AUX FALSE") THEN
"HMI_Variables_Status"."Meters"."QTM3012_PRD_Fault" := FALSE;
END_IF;
IF (NOT "AUX FALSE") THEN
"gmPDS2000_Error_Fault" := FALSE;
END_IF;
IF (NOT "AUX FALSE") THEN
"HMI_Variables_Status"."Meters"."QTM3012_PRD_Run" := FALSE;
END_IF;
IF (NOT "AUX FALSE") THEN
"gNoFreezeProductMeter" := FALSE;
END_IF;
// Network 11: Filler Bottle Count Used to push Product (Original Language: LAD)
"System_RunOut_Variables"."ProdPipeRunOutFillerBott" := (NOT "System_RunOut_Variables"."ProdPipeRunOutWaterCount");
// Network 12: Water Bypass Enable (Original Language: LAD)
"gStillWaterByPassEn" := (("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_StillWaterByPass" OR ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_ByPassDeair" AND (NOT "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Deaireation"))) AND "Blender_Variables_Pers"."gWaterRecipe") AND (NOT "Blender_Variables_Pers"."gCarboStillRecipe");
// Network 13: Still Water Bypass (Original Language: LAD)
"gBlendFiStillWaterByPass" := (("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_BlendFillSystem" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_StillWaterByPass") AND "Blender_Variables_Pers"."gWaterRecipe") AND (NOT "Blender_Variables_Pers"."gCarboStillRecipe");
// Network 14: Manual Syrup Drain Valve Open - Operator Alarm (Original Language: LAD)
"gHVP301_Open" := (("gSyrupRoomEn" AND (NOT "gIN_HVP301_Aux")) AND (NOT "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_FastChangeOverEnabled") AND "Procedure_Variables"."FTP302Line_Preparation"."Done") AND (NOT "Procedure_Variables"."Syr_RunOut"."Done") OR (((("gSyrupRoomEn" AND (NOT "gIN_HVP301_Aux")) AND "gBlenderCIPMode") AND "gIN_CIP_CIPRunning") AND "Procedure_Variables"."Blender_Run"."Running");
// Network 15: Manual Syrup Drain Valve Open - Operator Alarm (Original Language: LAD)
"mHVM302_Dly"(IN := "gIN_HVM302_Aux", PT := S5T#1S); // TODO: Declarar "mHVM302_Dly" : TON; en VAR_STAT o VAR
"gHVM302_Open" := "mHVM302_Dly".Q;
// Network 16: Maselli Control (Original Language: LAD)
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_MeterType" = 6 THEN
Maselli_PA_Control();
END_IF;
// Network 17: mPDS Control (Original Language: LAD)
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_MeterType" = 5 THEN
mPDS_PA_Control();
END_IF;
// Network 18: mPDS Syrup Control (Original Language: LAD)
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_SyrBrixMeter" THEN
mPDS_SYR_PA_Control();
END_IF;
// Network 19: Co2 Analog Input (Original Language: LAD)
// GetProdBrixCO2_FromAnalogIn
// CALL "GetProdBrixCO2_FromAn"
// NOP 0
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_MeterType" = 3 THEN
GetProdBrixCO2_Anal_Inpt();
END_IF;
// Network 20: Quality (Original Language: LAD)
ProductQuality();
// Network 21: Input Data (Original Language: LAD)
"Input_Data"();
// Network 22: Sel Brix Source Check (Original Language: LAD)
SelCheckBrixSource();
// Network 23: Check Water Cooling System Temperature (Original Language: LAD)
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_InverterRecirPumpPPM306" THEN
CTRLCoolingSystem();
END_IF;
// Network 24: Tank Level (Original Language: LAD)
TankLevel();
// Network 25: Production ONS (Original Language: LAD)
// PBox Logic moved to consumer Coil
"gProductionONS" := ("gBlenderProdMode" AND NOT "M19001") AND (NOT "mDelayPowerOnTmr");
// Network 26: Blender Prod Mode Init (Original Language: LAD)
IF ("gProductionONS" OR "Procedure_Variables"."Blender_Rinse"."ONS_Done") AND (NOT "Blender_Variables_Pers"."gBlenderStarted") THEN
BlenderCtrl_ProdModeInit();
END_IF;
// Network 27: Rinse ONS (Original Language: LAD)
// PBox Logic moved to consumer Coil
"gRinseONS" := ("HMI_Variables_Status"."System"."Blender_Prod_CIP" AND NOT "M19002") AND (NOT "mDelayPowerOnTmr");
// Network 28: CIP ONS (Original Language: LAD)
// PBox Logic moved to consumer Coil
"gCIPONS" := ("gBlenderCIPMode" AND NOT "M19003") AND (NOT "mDelayPowerOnTmr");
// Network 29: CIp Mode Init (Original Language: LAD)
IF "gCIPONS" THEN
BlenderCtrl_CIPModeInit();
END_IF;
// Network 30: Reset SPWords (Original Language: LAD)
BlenderCtrl_ResetSPWord();
// Network 31: Blender Run Control (Original Language: LAD)
BlenderRun__Control();
// Network 32: Tank Pressure Control (Original Language: LAD)
Prod_Tank_PressCtrl();
// Network 33: Balaiage (Original Language: LAD)
Baialage();
// Network 34: First Production (Original Language: LAD)
"FirstProduction_Data"();
// Network 35: CIP MAIN Calling (Original Language: LAD)
CIPMain();
// Network 36: Blender Rinse (Original Language: LAD)
BlenderRinse();
// Network 37: Safeties (Original Language: LAD)
Safeties();
// Network 38: Instrument Scanner (Original Language: LAD)
Instrument_Scanner();
// Network 39: Vacuum Control (Original Language: LAD)
VacuumCtrl();
// Network 40: Syrup Room Control (Original Language: LAD)
SyrupRoomCtrl();
// Network 41: Blend Procedure Data (Original Language: LAD)
IF (NOT "mDelayPowerOnTmr") THEN
"Blender_Procedure Data"();
END_IF;
// Network 42: Pneumatic Valve Control (Original Language: LAD)
Pneumatic_Valve_Ctrl();
// Network 43: Pumps Control (Original Language: LAD)
PumpsControl();
// Network 44: Prod Report Manager (Original Language: LAD)
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Report" THEN
ProdReportManager();
END_IF;
// Network 45: Outputs (Original Language: LAD)
Output();
// Network 46: SLIM BLOCK (Original Language: LAD)
SLIM_Block();
// Network 47: Interlocking Panel 1 (Original Language: LAD)
Interlocking_Panel_1();
// Network 48: Filler Control (Original Language: LAD)
FillerControl();
// Network 49: Blender Ctrl Update PWORD (Original Language: LAD)
BlenderCtrl_UpdatePWord();
// Network 50: ResetTotalizer (Original Language: LAD)
"mResetTotalizerTmr"(IN := "gBlendResetTotalizer", PT := S5T#2S); // TODO: Declarar "mResetTotalizerTmr" : TP; en VAR_STAT o VAR
// Network 51: ResetWaterTot (Original Language: LAD)
"mResetFTN301TotTmr"(IN := "gFTN301_ResetTot" OR "mResetTotalizerTmr", PT := S5T#2S); // TODO: Declarar "mResetFTN301TotTmr" : TP; en VAR_STAT o VAR
"mResetWaterTot" := "mResetFTN301TotTmr".Q;
// Network 52: Water VFM Reset Totalizer (Original Language: LAD)
IF "gFTN301_ResetTot" THEN
"gFTN301_ResetTot" := FALSE;
END_IF;
// Network 53: ResetCO2Tot (Original Language: LAD)
"mResetFTP302TotTmr"(IN := "gFTP302_ResetTot" OR "mResetTotalizerTmr", PT := S5T#2S); // TODO: Declarar "mResetFTP302TotTmr" : TP; en VAR_STAT o VAR
"mResetSyrupTot" := "mResetFTP302TotTmr".Q AND "gSyrupRoomEn";
// Network 54: Syrup MFM Reset Totalizer (Original Language: LAD)
IF "gFTP302_ResetTot" THEN
"gFTP302_ResetTot" := FALSE;
END_IF;
// Network 55: ResetProductTot (Original Language: LAD)
"mResetFTM303TotTmr"(IN := "gFTM303_ResetTot" OR "mResetTotalizerTmr", PT := S5T#2S); // TODO: Declarar "mResetFTM303TotTmr" : TP; en VAR_STAT o VAR
"mResetCO2Tot" := "mResetFTM303TotTmr".Q;
// Network 56: CO2 MFM Reset Tot (Original Language: LAD)
IF "gFTM303_ResetTot" THEN
"gFTM303_ResetTot" := FALSE;
END_IF;
// Network 57: ResetCO2Tot (Original Language: LAD)
"mResetProductTotTmr"(IN := "gProductMFMResetTot" OR "mResetTotalizerTmr", PT := S5T#2S); // TODO: Declarar "mResetProductTotTmr" : TP; en VAR_STAT o VAR
"mResetProductTot" := "mResetProductTotTmr".Q;
// Network 58: Reset Totalizer (Original Language: LAD)
IF "gProductMFMResetTot" THEN
"gProductMFMResetTot" := FALSE;
END_IF;
// Network 59: Reset Totalizer (Original Language: LAD)
IF "gBlendResetTotalizer" THEN
"gBlendResetTotalizer" := FALSE;
END_IF;
// Network 60: Blender Ctrl Command (Original Language: LAD)
IF (NOT "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Simulation") THEN
BlenderCtrl_MFM_Command();
END_IF;
// Network 61: DP Global Diag (Original Language: LAD)
CPU_DP_Global_Diag();
// Network 62: Profibus (Original Language: LAD)
Profibus_Network();
// Network 63: Valve Fault (Original Language: LAD)
ModValveFault();
// Network 64: All Auto (Original Language: LAD)
// NBox Logic moved to consumer Coil
IF NOT ("HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Command" AND "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Enable") AND "M19011" THEN
BlenderCtrl_All_Auto();
END_IF;
"HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Light" := "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Command" AND "HMI_Variables_Cmd"."Commands_From_HMI"."F7_DeviceControl"."Enable";
// Network 65: Ctrl HMI Manual Active (Original Language: LAD)
BlenderCtrl_ManualActive();
// Network 66: Mod Copy Recipe (Original Language: LAD)
"mAux_FP_M700_1" := "HMI_Variables_Cmd"."Recipe"."Main_Page" AND (NOT "mFP_Recip_Main_Page");
"mFP_Recip_Main_Page" := "HMI_Variables_Cmd"."Recipe"."Main_Page";
"T_Pulse_Recipe_Edit"(IN := "HMI_Variables_Cmd"."Recipe"."Main_Page" AND "HMI_Variables_Cmd"."Recipe"."Edit", PT := S5T#500ms); // TODO: Declarar "T_Pulse_Recipe_Edit" : TP; en VAR_STAT o VAR
IF "T_Pulse_Recipe_Edit".Q AND "T_Pulse_Recipe_Edit" THEN
"HMI_Variables_Cmd"."Recipe"."Edit" := FALSE;
END_IF;
IF "mAux_FP_M700_1" THEN
"HMI_Variables_Cmd"."Recipe"."Edit" := TRUE;
END_IF;
// Network 67: to HMI - Recipe Management (Original Language: LAD)
IF "AUX TRUE" THEN
"RecipeManagement_Data"();
END_IF;
// Network 68: Recipe Calculation (Original Language: LAD)
RecipeCalculation();
END_FUNCTION_BLOCK