Obsidean_VM/.obsidian/plugins/text-extractor/cache/c69ef73ce49635a7b47576774ea...

1 line
18 KiB
JSON
Raw Normal View History

2025-02-18 05:37:27 -03:00
{"path":"01-Documentation/SIEMENS & WINCC/PLC Siemens/adjuntos/Specs 6ES75152AN030AB0_datasheet_en.pdf","text":"Data sheet 6ES7515-2AN03-0AB0 SIMATIC S7-1500, CPU 1515-2 PN, central processing unit with work memory 1 MB for program and 4.5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 6 ns bit performance, SIMATIC Memory Card required - - approvals and certificates according to entry 109817466 at support.industry.siemens.com to be considered! - - General information Product type designation CPU 1515-2 PN HW functional status FS04 Firmware version V3.1 FW update possible Yes Product function I&M data Yes; I&M0 to I&M3 Isochronous mode Yes; Distributed and central; with minimum OB 6x cycle of 375 µs (distributed) and 1 ms (central) SysLog Yes Engineering with STEP 7 TIA Portal configurable/integrated from version V19 (FW V3.1) / V18 (FW V3.0) or higher; with older TIA Portal versions configurable as 6ES7515-2AM02-0AB0 Configuration control via dataset Yes Display Screen diagonal [cm] 6.1 cm Control elements Number of keys 8 Mode buttons 2 Supply voltage Rated value (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V Reverse polarity protection Yes Mains buffering Mains/voltage failure stored energy time 5 ms Repeat rate, min. 1/s Input current Current consumption (rated value) 0.65 A Current consumption, max. 1.03 A Inrush current, max. 1.15 A; Rated value I²t 0.6 A²·s Power Infeed power to the backplane bus 12 W Power consumption from the backplane bus (balanced) 6.2 W Power loss 6ES75152AN030AB0 Page 1/9 11/11/2024 Subject to change without notice © Copyright Siemens Power loss, typ. 3.6 W Memory Number of slots for SIMATIC memory card 1 SIMATIC memory card required Yes Work memory integrated (for program) 1 Mbyte integrated (for data) 4.5 Mbyte Load memory Plug-in (SIMATIC Memory Card), max. 32 Gbyte Backup maintenance-free Yes CPU processing times for bit operations, typ. 6 ns for word operations, typ. 7 ns for fixed point arithmetic, typ. 9 ns for floating point arithmetic, typ. 37 ns CPU-blocks Number of elements (total) 8 000; Blocks (OB, FB, FC, DB) and UDTs DB Number range 1 ... 60 999; subdivided into: number range that can be used by the user: 1 ... 59 999, and number range of DBs created via SFC 86: 60 000 ... 60 999 Size, max. 4.5 Mbyte; For DBs with absolute addressing, the max. size is 64 KB FB Number range 0 ... 65 535 Size, max. 1 Mbyte FC Number range 0 ... 65 535 Size, max. 1 Mbyte OB Size, max. 1 Mbyte Number of free cycle OBs 100 Number of time alarm OBs 20 Number of delay alarm OBs 20 Number of cyclic interrupt OBs 20; With minimum OB 3x cycle of 250 µs Number of process alarm OBs 50 Number of DPV1 alarm OBs 3 Number of isochronous mode OBs 2 Number of technology synchronous alarm OBs 2 Number of startup OBs 100 Number of asynchronous error OBs 4 Number of synchronous error OBs 2 Number of diagnostic alarm OBs 1 Nesting depth per priority class 24 Counters, timers and their retentivity S7 counter Number 2 048 Retentivity adjustable Yes IEC counter Number Any (only limited by the main memory) Retentivity adjustable Yes S7 times Number 2 048 Retentivity adjustable Yes IEC timer Number Any (only limited by the main memory) Retentivity adjustable Yes 6ES75152AN030AB0 Page 2/9 11/11/2024 Subject to change without notice © Copyright Siemens Data areas and their retentivity Retentive data area (incl. timers, counters, flags), max. 512 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 472 KB Extended retentive data area (incl. timers, counters, flags), max. 4.5 Mbyte; When using PS 6 0W 24/48/60 V DC HF Flag Size, max. 16 kbyte Number of clock memories 8; 8 clock memory bit, grouped into one clock memory byte Data blocks Retentivity adjustable Yes Retentivity preset No Local data p