* Two main parts
|
||
|
* FB Tilting
|
||
|
* Sic : Synchronism?
|
||
|
* Cont ?
|
||
|
* Sensor for tensioning?
|
||
|
* Max ? Overspeed?
|
||
|
* Min : Stop / Start
|
||
|
* Variable Speed. - = reference by filler
|
||
|
* Formats: ? 66mm a 93mm => 27mm. How is changed?
|
||
|
* Start:
|
||
|
* Fill to Sic with minimum accumulation
|
||
|
* Run chain at fixed speed
|
||
|
* Wait for phase to start ( the phase and the ramp of doser must be parametrized)
|
||
|
* After some bottles go in ramp to variable speed
|
||
|
* FB Skid
|
||
|
* Inputs:
|
||
|
* TT1 : water temperature
|
||
|
* LT1 : water level sensor
|
||
|
* PT1 : pressure sensor ( max control => alarm )
|
||
|
* Outputs:
|
||
|
* AMV1: valve to modulate cool water to the Skid
|
||
|
* If P1 is running and TT1 > min -> open then valve
|
||
|
* P1 : water pump
|
||
|
* STOP LT1 < min
|
||
|
* START LT1 > medium
|
||
|
* AV1 : Water filling and top-up valve
|
||
|
|
||
|
|
||
|
![[Pasted image 20240410153217.png]]
|
||
|
|
||
|
### Formats:
|
||
|
***
|
||
|
|
||
|
| ID | FORMATO | Ø x H | Ø collo | Tempo di tilting (s) | Max m/m | Min m/m | Produz. b/h |
|
||
|
|:---:|:----------------:|:------------:|:-------:|:--------------------:|:-------:|:-------:|:-----------:|
|
||
|
| 1 | 500 ml Piala | 66,3 x 226,1 | 30 | 12 | 82 | 35 | 32.000 |
|
||
|
| 2 | 960 ml Piala | 84 x 271,7 | 29,7 | | | | 27.000 |
|
||
|
| 3 | 1000 ml - Lipton | 84 x 270,21 | 29,7 | 12,6 | 79 | 42 | 30.000 |
|
||
|
| 4 | 1500 ml - Lipton | 93 x 320,21 | 29,7 | 20,5 | 48 | 29 | 18.500 |
|
||
|
|
||
|
Se tiltling length = 16,5m
|
||
|
Max => v = (16,5 m / ts )* 60
|
||
|
Min => bot speed
|
||
|
|
||
|
|
||
|
|
||
|
### Promemoria:
|
||
|
***
|
||
|
* Cavo valvola modulante & scheda uscita?
|
||
|
* Disegno 3D per sinotico?
|
||
|
|
||
|
|
||
|
|