Obsidean_VM/04-InLavoro/HENKEL/93040 - HENKEL - BowlingGreen/TL22-L25/24 - 9.4006 - Feedback flow.../9.4006 - Feedback flow - No...

863 B

Q3 PLC:


  • Modified FC8 - Seg. 6:

!Pasted image 20240502095740.png

Changed comments on the "ToQ1_D".ToHenkel.SignalExchange.Labeller.di15 to Flow Selection - 1=Old Labeler, 2=New PE Labeler, 0=Flow error

Q1 PLC:


Changed comments on:

  • "FromQ3_D".ToHenkel.SignalExchange.Labeller.di15 : to "Flow Selection - 1=Old Labeler, 2=New PE Labeler, 0=Flow error"
  • "ComSV".TL22_WriteToSv.ToHenkel.SignalExchange.Labeller.di15 : to "Flow Selection - 1=Old Labeler, 2=New PE Labeler, 0=Flow error"

No need to change the logic because: on FC13 - Net 13:

...
"ComSV".TL22_WriteToSv.ToHenkel.SignalExchange.Labeller :=
"FromQ3_D".ToHenkel.SignalExchange.Labeller;

...

Then this is used on the FC7 - Net 15:

...
#ToHenkel := "ComSV".TL22_WriteToSv.ToHenkel;
...

So the data from Q3 goes to the Prosoft on Q1