4.4 KiB
4.4 KiB
// Block Type: FB
// Block Name (Original): ProcedureDeaireator StartUp
// Block Number: 1803
// Original Network Languages: LAD
FUNCTION_BLOCK "ProcedureDeaireator_StartUp"
{ S7_Optimized_Access := 'TRUE' }
VERSION : 0.1
VAR_STAT
mStepNum : Int;
mTimeStep : Int;
mTransition : Bool;
mDeairStartUpONS : Bool;
END_VAR
BEGIN
// Network 1: Qualifier (Original Language: LAD)
"Procedure_Variables"."TN301_StartUp"."Qualifier" := ("gBlenderProdMode" AND "gBlenderRinseMode" AND "gBlenderSuppliesOk") OR ("gBlenderRinseMode" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Deaireation" AND "gBlenderSuppliesOk");
// Network 2: Reset (Original Language: LAD)
"Procedure_Variables"."TN301_StartUp"."Reset" := "gBlenderCIPMode" OR ("gBlenderRinseMode" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_Deaireation");
// Network 3: Done (Original Language: LAD)
IF "Procedure_Variables"."TN301_StartUp"."Reset" THEN
"mStepNum" := 0;
"mTimeStep" := 0;
END_IF;
IF "Procedure_Variables"."TN301_StartUp"."Reset" THEN
"Procedure_Variables"."TN301_StartUp"."Done" := FALSE;
END_IF;
// Network 4: Request (Original Language: LAD)
// PBox SymPy processed, logic in consumer
"mDeairStartUpONS" := "HMI_Variables_Cmd"."Commands_From_HMI"."CMD_TN301_StartUp" OR "Procedure_Variables"."Blender_Run"."Request"; // P_TRIG("HMI_Variables_Cmd"."Commands_From_HMI"."CMD_TN301_StartUp" OR "Procedure_Variables"."Blender_Run"."Request") - Mem: "mDeairStartUpONS"
"Procedure_Variables"."TN301_StartUp"."Request" := ("HMI_Variables_Cmd"."Commands_From_HMI"."CMD_TN301_StartUp" AND "Procedure_Variables"."TN301_StartUp"."Qualifier" AND NOT "mDeairStartUpONS") OR ("Procedure_Variables"."Blender_Run"."Request" AND "Procedure_Variables"."TN301_StartUp"."Qualifier" AND NOT "mDeairStartUpONS");
// Network 5: Wait (Original Language: LAD)
"Procedure_Variables"."TN301_StartUp"."Wait" := "HMI_Device"."PPN301"."Alarm" OR ("gCO2LowPress_Fault" AND "gWorkshopTest") OR ("HMI_Digital"."_PAL_S11"."Filtered" AND "Disable_Bit" AND "gWorkshopTest");
// Network 6: State (Original Language: LAD)
"Procedure_Variables"."TN301_StartUp"."Latch" := ("Procedure_Variables"."TN301_StartUp"."Request" AND "Procedure_Variables"."TN301_StartUp"."Done" AND "Procedure_Variables"."TN301_StartUp"."Reset") OR ("Procedure_Variables"."TN301_StartUp"."Done" AND "Procedure_Variables"."TN301_StartUp"."Latch" AND "Procedure_Variables"."TN301_StartUp"."Reset");
IF ("Procedure_Variables"."TN301_StartUp"."Request" AND "Procedure_Variables"."TN301_StartUp"."Done" AND "Procedure_Variables"."TN301_StartUp"."Reset") OR ("Procedure_Variables"."TN301_StartUp"."Done" AND "Procedure_Variables"."TN301_StartUp"."Latch" AND "Procedure_Variables"."TN301_StartUp"."Reset") THEN
"HMI_Variables_Status"."Procedures"."BlenderStateNum" := 5;
END_IF;
// Network 7: Message (Original Language: LAD)
"HMI_Alarms"."gH_Message" := ("gBlenderProdMode" AND "Procedure_Variables"."TN301_StartUp"."Qualifier" AND "Procedure_Variables"."TN301_StartUp"."Done" AND "HMI_Blender_Parameters"."Actual_Recipe_Parameters"."_EnDeaireation" AND "Procedure_Variables"."TN301_StartUp"."Latch") OR ("gBlenderProdMode" AND "Procedure_Variables"."TN301_StartUp"."Qualifier" AND "Procedure_Variables"."TN301_StartUp"."Done" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_ByPassDeair" AND "Procedure_Variables"."TN301_StartUp"."Latch");
// Network 8: Running (Original Language: LAD)
"Procedure_Variables"."TN301_StartUp"."Running" := "Procedure_Variables"."TN301_StartUp"."Wait" AND "Procedure_Variables"."TN301_StartUp"."Latch";
// Network 9: Deaireator Start UP Sequence (Original Language: LAD)
IF "Procedure_Variables"."TN301_StartUp"."Running" THEN
Deaireator_StartUp_Seq(mStep := "mStepNum", mTimer := "mTimeStep", mTransition := "mTransition");
END_IF;
// Network 10: Deaerator StartUp Running (Original Language: LAD)
"HMI_Variables_Status"."Procedures"."TN301StartUpRun" := "Procedure_Variables"."TN301_StartUp"."Latch";
"HMI_Alarms"."gH_Status" := "Procedure_Variables"."TN301_StartUp"."Latch";
// Network 11: MIX - Procedure auxiliary variable (Original Language: LAD)
"gSP_PPN304" := "HMI_Blender_Parameters"."Actual_Recipe_Parameters"."_Deareation_Vacum" AND "gStillWaterByPassEn" AND ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_VacuumPump" >= 1);
END_FUNCTION_BLOCK