// Block Type: FC
// Block Name (Original): Prod Tank RunOut_Seq
// Block Number: 1808
// Original Network Languages: STL, LAD
FUNCTION "Prod_Tank_RunOut_Seq" : Void
{ S7_Optimized_Access := 'TRUE' }
VERSION : 0.1
VAR_INPUT
ProdTankRanOut : Bool;
END_VAR
VAR_INOUT
mStep : Int;
mTime : Int;
mTransition : Bool;
mPrdTnkMinLvl : Bool;
END_VAR
VAR_TEMP
mProdTankMinLevel : Bool;
__PlcmigTempFillBit_0B1 : Bool;
__PlcmigTempFillBit_0B2 : Bool;
__PlcmigTempFillBit_0B3 : Bool;
__PlcmigTempFillBit_0B4 : Bool;
__PlcmigTempFillBit_0B5 : Bool;
__PlcmigTempFillBit_0B6 : Bool;
__PlcmigTempFillBit_0B7 : Bool;
__PlcmigTempFillBit_1B0 : Bool;
__PlcmigTempFillBit_1B1 : Bool;
__PlcmigTempFillBit_1B2 : Bool;
__PlcmigTempFillBit_1B3 : Bool;
__PlcmigTempFillBit_1B4 : Bool;
__PlcmigTempFillBit_1B5 : Bool;
__PlcmigTempFillBit_1B6 : Bool;
__PlcmigTempFillBit_1B7 : Bool;
END_VAR
BEGIN
// Network 1: STEP CONTROL (Original Language: STL)
// --- BEGIN STL Network 1 ---
L "mStep"
JL LEND
JU ST00
JU ST01
JU ST02
JU ST03
LEND: JU FULL
FULL: L 0
T "mStep"
JU END
// --- END STL Network 1 ---
// Network 2: STEP 00 (Original Language: LAD)
IF "HMI_Digital"."LSN301L"."Filtered" AND ("System_RunOut_Variables"."RMM301_OV_ProdPipeRunOut" > 0.0) THEN
"gSP_PPN301" := TRUE;
END_IF;
// Network 3: STEP 00 (Original Language: LAD)
IF ("HMI_Digital"."LAL_S3"."Filtered" AND "System_RunOut_Variables"."FastChangeOverActivated" AND ("System_RunOut_Variables"."RMP302_OV_ProdPipeRunOut" > 0)) OR ("gIN_SyrTank_MinLvl" AND "System_RunOut_Variables"."FastChangeOverActivated" AND ("System_RunOut_Variables"."RMP302_OV_ProdPipeRunOut" > 0)) THEN
"gSP_PPP302" := TRUE;
END_IF;
IF ("HMI_Digital"."LAL_S3"."Filtered" AND "System_RunOut_Variables"."FastChangeOverActivated" AND ("System_RunOut_Variables"."RMP302_OV_ProdPipeRunOut" > 0)) OR ("gIN_SyrTank_MinLvl" AND "System_RunOut_Variables"."FastChangeOverActivated" AND ("System_RunOut_Variables"."RMP302_OV_ProdPipeRunOut" > 0)) THEN
"gSP_AVP390" := TRUE;
END_IF;
// Network 4: STEP 00 (Original Language: LAD)
IF "AUX TRUE" THEN
"gSP_RVN301" := TRUE;
END_IF;
IF "System_RunOut_Variables"."FastChangeOverActivated" AND "AUX TRUE" THEN
"gSP_RVP303" := TRUE;
END_IF;
// Network 5: STEP 00 (Original Language: LAD)
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_DoubleDeair" THEN
"gSP_RVN301_1" := TRUE;
END_IF;
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_DoubleDeair" THEN
"gSP_PPN305" := TRUE;
END_IF;
// Network 6: STEP 00 (Original Language: STL)
// --- BEGIN STL Network 6 ---
A "System_RunOut_Variables".ChillerPushDone
= "__PlcmigTempFillBit_1B0"
BLD 103
A "AUX TRUE"
= "__PlcmigTempFillBit_1B1"
BLD 103
A "Procedure_Variables".TM301_RunOut.Wait
= "__PlcmigTempFillBit_1B2"
BLD 103
A CLK_0.5S
= "__PlcmigTempFillBit_1B3"
BLD 103
CALL "_StepMove"
A _Statusword_?
JC END
// --- END STL Network 6 ---
// Network 7: STEP 01 (Original Language: LAD)
IF "AUX TRUE" THEN
"gRinseClose_RMM301" := TRUE;
END_IF;
IF "AUX TRUE" THEN
"gRinseClose_RMP302" := TRUE;
END_IF;
// Network 8: STEP 01 (Original Language: STL)
// --- BEGIN STL Network 8 ---
A "AUX TRUE"
= "__PlcmigTempFillBit_1B0"
BLD 103
A "AUX TRUE"
= "__PlcmigTempFillBit_1B1"
BLD 103
A "Procedure_Variables".TM301_RunOut.Wait
= "__PlcmigTempFillBit_1B2"
BLD 103
A CLK_0.5S
= "__PlcmigTempFillBit_1B3"
BLD 103
CALL "_StepMove"
A _Statusword_?
JC END
// --- END STL Network 8 ---
// Network 9: STEP 02 (Original Language: LAD)
"mProdTankMinLevel" := ("HMI_Instrument"."LTM302"."PVFiltered" < 2.0) OR ("ProdTankRanOut" AND "System_RunOut_Variables"."ProdPipeRunOutFillerBott");
// Network 10: STEP 02 (Original Language: STL)
// --- BEGIN STL Network 10 ---
A "mProdTankMinLevel"
= "__PlcmigTempFillBit_1B0"
BLD 103
A "AUX TRUE"
= "__PlcmigTempFillBit_1B1"
BLD 103
A "Procedure_Variables".TM301_RunOut.Wait
= "__PlcmigTempFillBit_1B2"
BLD 103
A CLK_0.5S
= "__PlcmigTempFillBit_1B3"
BLD 103
CALL "_StepMove"
A _Statusword_?
JC END
// --- END STL Network 10 ---
// Network 11: STEP 03 (Original Language: LAD)
IF "AUX FALSE" THEN
"gRinseClose_RMM301" := FALSE;
END_IF;
IF "AUX FALSE" THEN
"gRinseClose_RMP302" := FALSE;
END_IF;
IF "AUX FALSE" THEN
"System_RunOut_Variables"."ChillerPushDone" := FALSE;
END_IF;
IF "AUX FALSE" THEN
"Procedure_Variables"."TM301_RunOut"."Done" := TRUE;
END_IF;
// Network 12: (Original Language: STL)
// --- BEGIN STL Network 12 ---
END: NOP_0
// --- END STL Network 12 ---
END_FUNCTION