751 B
751 B
// Block Type: FC
// Block Number: 40
// Original Network Languages: STL
FUNCTION "T_Timer" : Void
{ S7_Optimized_Access := 'TRUE' }
VERSION : 0.1
VAR_INPUT
Preset : Int;
Start : Bool;
Stop : Bool;
Reset : Bool;
Base : Bool;
END_VAR
VAR_OUTPUT
End : Bool;
END_VAR
VAR_INOUT
Actual : Int;
END_VAR
BEGIN
// Network 1: (Original Language: STL)
// --- BEGIN STL Network 1 ---
AN "Start"
O "Reset"
JC NOTM
L "Actual"
L "Preset"
GE_I
= "End"
AN "Base"
O "End"
O "Stop"
BEC
L "Actual"
ADD 1
T "Actual"
BEU
NOTM: L 0
T "Actual"
R "End"
// --- END STL Network 1 ---
END_FUNCTION