```pascal
|
|
// Block Type: FC
|
|
// Block Number: 2028
|
|
// Original Network Languages: STL, LAD
|
|
|
|
FUNCTION "FillerControl" : Void
|
|
{ S7_Optimized_Access := 'TRUE' }
|
|
VERSION : 0.1
|
|
|
|
VAR_TEMP
|
|
Buffer : Bool;
|
|
EnableNextRecipe : Int;
|
|
mFillerTracked : Bool;
|
|
mAuxCalc : Real;
|
|
mAuxCalc1 : DInt;
|
|
mAuxRunOut : Int;
|
|
mAuxProdTemp : Int;
|
|
mAuxProductCarbo : Int;
|
|
mAuxProdTankPress : Int;
|
|
mAuxRecCarbo : Real;
|
|
mAuxProdCO2PressSP : Real;
|
|
END_VAR
|
|
|
|
BEGIN
|
|
|
|
// Network 1: To Filler Production (Original Language: LAD)
|
|
|
|
"gOUT_FillerProduction" := ("gBlenderProdMode" AND "gBlenderRinseMode") OR ("gBlenderProdMode" AND "System_RunOut_Variables"."FastChangeOverActivated");
|
|
|
|
// Network 2: #mFillerTracked (Original Language: LAD)
|
|
|
|
"mAuxCalc" := "Blender_Variables"."gMinProduction" / 2.0;
|
|
|
|
"mAuxCalc" := "Blender_Variables"."gEstimateFillerSpeed" + "mAuxCalc";
|
|
|
|
"mFillerTracked" := "Blender_Variables"."gActual_Prod_SP" >= "mAuxCalc";
|
|
|
|
// Network 3: To Filler Product Available (Original Language: LAD)
|
|
|
|
"gProdAvailable" := "gBlenderProdMode" AND "Procedure_Variables"."First_Production"."Done" AND "System_RunOut_Variables"."ProdPipe_RunOut"."Latch";
|
|
|
|
// Network 4: To Filler Minimum Level (Original Language: LAD)
|
|
|
|
"gOUT_FillerMinimumLevel" := "gBlenderLevelOk" AND "gProdAvailable";
|
|
|
|
// Network 5: To Filler Product Available (Original Language: LAD)
|
|
|
|
"gOUT_FillerProductAvail" := ("gPrdTank_Empty" AND "gIN_VoltageOk" AND "gPrdTank_Press_Fault" AND "HMI_Device"."PPM303"."Alarm" AND "gProdAvailable") OR ("gIN_VoltageOk" AND "gPrdTank_Press_Fault" AND "HMI_Device"."PPM303"."Alarm" AND "System_RunOut_Variables"."ProdPipe_RunOut"."Latch" AND "gProdAvailable");
|
|
|
|
// Network 6: RunOut Request (Original Language: LAD)
|
|
|
|
"System_RunOut_Variables"."Out_Flr_FillerRunOutReq" := "System_RunOut_Variables"."ToFillerProdRunOut";
|
|
|
|
// Network 7: Product Completed (Original Language: LAD)
|
|
|
|
"System_RunOut_Variables"."Out_Flr_ProductCompleted" := "System_RunOut_Variables"."ToFillerProductCompleted";
|
|
|
|
// Network 8: Filler RunOut (Original Language: LAD)
|
|
|
|
// PBox SymPy processed, logic in consumer
|
|
"M19013" := "System_RunOut_Variables"."In_Flr_WaterRinseRequest" OR "System_RunOut_Variables"."In_Flr_LastContainer"; // P_TRIG("System_RunOut_Variables"."In_Flr_WaterRinseRequest" OR "System_RunOut_Variables"."In_Flr_LastContainer") - Mem: "M19013"
|
|
|
|
IF ("System_RunOut_Variables"."In_Flr_WaterRinseRequest" AND NOT "M19013") OR ("System_RunOut_Variables"."In_Flr_LastContainer" AND NOT "M19013") THEN
|
|
"System_RunOut_Variables"."FillerRanOut" := TRUE;
|
|
END_IF;
|
|
|
|
// Network 9: Fast Rinse Complete (Original Language: LAD)
|
|
|
|
"System_RunOut_Variables"."FromFillerFastRinseCompl" := "System_RunOut_Variables"."In_Flr_FastRinseComplete";
|
|
|
|
// Network 10: Fast Rinse Request (Original Language: LAD)
|
|
|
|
// Network 10 did not produce printable SCL code.
|
|
|
|
// Network 11: Water Rinse Ready (Original Language: LAD)
|
|
|
|
"System_RunOut_Variables"."Out_Flr_WaterRinseReady" := ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_BlendFillSystem" AND "Procedure_Variables"."Blender_Rinse"."Latch" AND "System_RunOut_Variables"."ProdPipe_RunOut"."Done") OR ("System_RunOut_Variables"."FillerTankRinseLoaded" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_BlendFillSystem" AND "System_RunOut_Variables"."ProdPipe_RunOut"."Done" AND "System_RunOut_Variables"."FastChangeOverActivated") OR ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_FillerRinseTank" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_BlendFillSystem" AND "System_RunOut_Variables"."ProdPipe_RunOut"."Done" AND "System_RunOut_Variables"."FastChangeOverActivated");
|
|
|
|
// Network 12: To Filler Rinse Mode (Original Language: LAD)
|
|
|
|
"gOUT_FillerRinseMode" := "gBlenderRinseMode" AND "Procedure_Variables"."Blender_Run"."Latch";
|
|
|
|
// Network 13: To Filler CIP Mode (Original Language: LAD)
|
|
|
|
"gOUT_FillerCIPMode" := ("Procedure_Variables"."Blender_Run"."Latch" AND "gBlenderCIPMode" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_LocalCIP") OR ("Procedure_Variables"."Blender_Run"."Latch" AND "gBlenderCIPMode" AND "gIN_CIP_CIPMode");
|
|
|
|
// Network 14: Caustic Recovery Run (Original Language: LAD)
|
|
|
|
// PBox SymPy processed, logic in consumer
|
|
"M19022" := "gIN_CIP_ChangeSanitize" AND "gWorkshopTest"; // P_TRIG("gIN_CIP_ChangeSanitize" AND "gWorkshopTest") - Mem: "M19022"
|
|
|
|
// Network 15: To Filler CIP Running (Original Language: LAD)
|
|
|
|
"gOUT_FillerCIPRunning" := ("gBlenderCIPMode" AND "HMI_Digital"."LSM302L"."Filtered" AND "gIN_CIP_CIPRunning") OR ("gBlenderCIPMode" AND "gBlenderMinLevel" AND "gIN_CIP_CIPRunning") OR ("Procedure_Variables"."Blender_Run"."Latch" AND "gBlenderCIPMode" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_LocalCIP" AND "HMI_Digital"."LSM302L"."Filtered" AND "gP_CIPRunning") OR ("Procedure_Variables"."Blender_Run"."Latch" AND "gBlenderCIPMode" AND "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_LocalCIP" AND "gBlenderMinLevel" AND "gP_CIPRunning");
|
|
|
|
// Network 16: To Filler CIP (Original Language: LAD)
|
|
|
|
"gOUT_FillerCIPChangeSani" := ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_LocalCIP" AND "gP_CIPChangeSanitize") OR ("CIP_Program_Variables"."Status"."CausticRecoveryRun" AND "CIP_Program_Variables"."Status"."BlenderEmpty");
|
|
|
|
// Network 17: To Filler CIP Drain Request (Original Language: LAD)
|
|
|
|
"gOUT_FillerCIPDrainReq" := "gIN_CIP_DrainRequest" OR ("CIP_Program_Variables"."Status"."BlenderDrainRunning" AND "CIP_Program_Variables"."Status"."Completed");
|
|
|
|
// Network 18: To Filler CIP Completed (Original Language: LAD)
|
|
|
|
"gOUT_FillerCIPCompleted" := ("HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_LocalCIP" AND "CIP_Program_Variables"."Status"."Completed") OR ("gIN_CIP_CIPCompleted" AND "Interlocking_Variables"."FILLER_MIXER_RECEIVE"."CIP_Selected");
|
|
|
|
// Network 19: Wait Filler Product Request After First Production (Original Language: LAD)
|
|
// Wait Filler Product Request After First Production
|
|
|
|
"HMI_Alarms"."gH_Message" := ("gBlenderProdMode" AND "gFirstProdStop") OR ("gBlenderProdMode" AND "gFiilerStopBlender");
|
|
|
|
// Network 20: Wait Filler Rinse Completed Signal (Original Language: LAD)
|
|
// Wait Filler Rinse Completed
|
|
|
|
// PBox SymPy processed, logic in consumer
|
|
"M19023" := "System_RunOut_Variables"."FastChangeOverActivated" AND "Procedure_Variables"."Blender_Rinse"."Running"; // P_TRIG("System_RunOut_Variables"."FastChangeOverActivated" AND "Procedure_Variables"."Blender_Rinse"."Running") - Mem: "M19023"
|
|
|
|
// Network 21: Filler Loads next recipe (Original Language: LAD)
|
|
// Filler Loads next recipe on the rising edge OF the Product Completed Signal, so
|
|
// AT that point the next recipe must be already selected.
|
|
|
|
IF "HMI_Variables_Cmd"."GLOBAL_CMD"."_EnableNextRecipe" THEN
|
|
"EnableNextRecipe" := "HMI_Blender_Parameters"."Actual_Recipe_Parameters"."_FillerNextRecipeNum";
|
|
END_IF;
|
|
|
|
IF "HMI_Variables_Cmd"."GLOBAL_CMD"."_EnableNextRecipe" THEN
|
|
"EnableNextRecipe" := 0;
|
|
END_IF;
|
|
|
|
IF "System_RunOut_Variables"."FastChangeOverActivated" AND "HMI_Variables_Cmd"."GLOBAL_CMD"."_EnableNextRecipe" AND "Procedure_Variables"."Syr_RunOut"."Done" THEN
|
|
"System_RunOut_Variables"."FillerNextRecipeNum" := "EnableNextRecipe";
|
|
END_IF;
|
|
|
|
IF "System_RunOut_Variables"."FastChangeOverActivated" OR "Procedure_Variables"."Syr_RunOut"."Done" THEN
|
|
"System_RunOut_Variables"."FillerNextRecipeNum" := "HMI_Blender_Parameters"."Actual_Recipe_Parameters"."_FillerNextRecipeNum";
|
|
END_IF;
|
|
|
|
"Buffer" := "System_RunOut_Variables"."FastChangeOverActivated" OR "Procedure_Variables"."Syr_RunOut"."Done";
|
|
|
|
// Network 22: RunOut Amount (Original Language: LAD)
|
|
|
|
// Network 22 did not produce printable SCL code.
|
|
|
|
// Network 23: RunOut Amount (Original Language: STL)
|
|
|
|
// --- BEGIN STL Network 23 ---
|
|
|
|
A_BRACK
|
|
L "System_RunOut_Variables".TotalProductAvailable
|
|
DTR
|
|
T "mAuxRunOut"
|
|
SET
|
|
SAVE
|
|
CLR
|
|
A _Statusword_?
|
|
BRACKET
|
|
JNB _007
|
|
L "mAuxRunOut"
|
|
T "MW116"
|
|
_007: NOP_0
|
|
|
|
// --- END STL Network 23 ---
|
|
|
|
// Network 24: RunOut Amount (Original Language: LAD)
|
|
|
|
"Interlocking_Variables"."SIDEL_FILLER_SEND_DATA"."Run_Out_Amount1" := "MB116";
|
|
|
|
// Network 25: RunOut Amount (Original Language: LAD)
|
|
|
|
"Interlocking_Variables"."SIDEL_FILLER_SEND_DATA"."Run_Out_Amount2" := "MB117";
|
|
|
|
// Network 26: Product Temperature (Original Language: STL)
|
|
|
|
// --- BEGIN STL Network 26 ---
|
|
|
|
A_BRACK
|
|
L "HMI_PID".RVM319_H2O.Pv
|
|
RND
|
|
T "mAuxProdTemp"
|
|
SET
|
|
SAVE
|
|
CLR
|
|
A _Statusword_?
|
|
BRACKET
|
|
JNB _008
|
|
L "mAuxProdTemp"
|
|
T "MB118"
|
|
_008: NOP_0
|
|
|
|
// --- END STL Network 26 ---
|
|
|
|
// Network 27: Product Temperature (Original Language: LAD)
|
|
|
|
"Interlocking_Variables"."SIDEL_FILLER_SEND_DATA"."Product_Temperature" := "MB118";
|
|
|
|
// Network 28: mAuxRecCarbo (Original Language: LAD)
|
|
|
|
"mAuxRecCarbo" := "HMI_Blender_Parameters"."Actual_Recipe_Parameters"."_CO2Vols" * 10.0;
|
|
|
|
// Network 29: AuxRecCarbo (Original Language: STL)
|
|
|
|
// --- BEGIN STL Network 29 ---
|
|
|
|
A_BRACK
|
|
L "mAuxRecCarbo"
|
|
RND
|
|
T "mAuxProductCarbo"
|
|
SET
|
|
SAVE
|
|
CLR
|
|
A _Statusword_?
|
|
BRACKET
|
|
JNB _009
|
|
L "mAuxProductCarbo"
|
|
T "MB120"
|
|
_009: NOP_0
|
|
|
|
// --- END STL Network 29 ---
|
|
|
|
// Network 30: Product Carbonation (Original Language: LAD)
|
|
|
|
"Interlocking_Variables"."SIDEL_FILLER_SEND_DATA"."Product_Carbonation" := "MB120";
|
|
|
|
// Network 31: Product C02 Pressure SP (Original Language: LAD)
|
|
// "Blender_Variables".gSP_CO2
|
|
|
|
"mAuxProdCO2PressSP" := "HMI_PID"."RVM301"."Pv" * 10.0;
|
|
|
|
// Network 32: Product C02 Pressure (Original Language: STL)
|
|
|
|
// --- BEGIN STL Network 32 ---
|
|
|
|
A_BRACK
|
|
L "mAuxProdCO2PressSP"
|
|
RND
|
|
T "mAuxProdTankPress"
|
|
SET
|
|
SAVE
|
|
CLR
|
|
A _Statusword_?
|
|
BRACKET
|
|
JNB _00a
|
|
L "mAuxProdTankPress"
|
|
T "MB122"
|
|
_00a: NOP_0
|
|
|
|
// --- END STL Network 32 ---
|
|
|
|
// Network 33: Product Tank Pressure SP (Original Language: LAD)
|
|
|
|
"Interlocking_Variables"."SIDEL_FILLER_SEND_DATA"."Prod_Tank_Press_SP" := "MB122";
|
|
|
|
// Network 34: Filler Data Send (Original Language: LAD)
|
|
|
|
IF "HMI_Blender_Parameters"."Processor_Options"."Blender_OPT"."_BlendFillSystem" THEN
|
|
FillerControl_DataSend();
|
|
END_IF;
|
|
|
|
// Network 35: Next Recipe (Original Language: LAD)
|
|
|
|
"Interlocking_Variables"."SIMO_FILLER_SEND_DATA"."Next_Recipe" := "System_RunOut_Variables"."FillerNextRecipeNum";
|
|
|
|
END_FUNCTION
|
|
|
|
```
|