2.0 KiB
2.0 KiB
!Pasted image 20250511151234.png
@startuml "Process Monitoring System"
' Title and styling
title Process Monitoring System with Signal Conversion
skinparam componentStyle rectangle
skinparam backgroundColor white
skinparam defaultTextAlignment center
' Define main packages
package "Syrup Line" {
rectangle "Syrup Pipe" as syrup #ADD8E6
component "Maselli UR29\nRefractometer" as ur29 #FFDD88
component "ADAM Module\n(RS485 to 4-20mA)" as adam1 #ADD8E6
note bottom of adam1: Converts RS485 to 4-20mA
component "Maselli UR62\nRefractometer" as ur62 #FFDD88
component "ADAM Module\n(RS485 to 4-20mA)" as adam2 #ADD8E6
note bottom of adam2: Converts RS485 to 4-20mA
}
package "Water Line" {
rectangle "Water Pipe" as water #ADD8E6
component "Conductivity 401U3\nProbe" as probe #FFDD88
component "2405 Knick\nTransmitter" as knick #B6D7A8
note bottom of knick: Converts conductivity signals to 4-20mA
}
component "PLC\nControl System" as plc #D5A6BD
' Connections
syrup --> ur29 : "Process\nMeasurement"
syrup --> ur62 : "Process\nMeasurement"
water --> probe : "Process\nMeasurement"
ur29 --> adam1 : "RS485"
ur62 --> adam2 : "RS485"
probe --> knick : "Conductivity\nSignal"
adam1 --> plc : "4-20mA"
adam2 --> plc : "4-20mA"
knick --> plc : "4-20mA"
@enduml
The equipment we tested was:
- Syrup / Brix:
- Maselli UR29 - Reflectometer
- ADAM 4021 converters for connecting the PLC
- ur24_gb_hr.pdf
- Maselli UR62 - Reflectometer
- ADAM 4021 converters for connecting the PLC
- ur62_gb_hr.pdf
- Maselli UR29 - Reflectometer
- Water :
- Clritalia: Conductivity - 401U3-B3C0Y0
- K=1 cm (campo di misura 0-50000 uS)
- 401U -gb
- Stratos Eco 2405 Knick converter for transmitting to the PLC
- K=1 cm (campo di misura 0-50000 uS)
- Clritalia: Conductivity - 401U3-B3C0Y0