1.0 KiB
1.0 KiB
!01-Documentation/Vetromeccanica/adjuntos/20240628_131621.jpg
From left to right the MAC:
- MOT_1: 52:CF
- MOT_2: 65:7C
- MOT_3: 52:B7
- MOT_4: 46LB6
In this way can be see the Analog inputs: Parameter->Inputs->Analog
Commisioning:
For Lenze 345v 0,55kw 120hz :
For automatic Restart on Siemens G120C:
P1210 = 6
- p1210 = 6: An automatic restart is carried out if any fault has occurred.
p840 = 1
- Sets the signal source for the command "ON/OFF (OFF1)"