1.6 KiB
1.6 KiB
the next code is taken from Q3 TL22 Henkel software:
Bit to selects CH1/2:
CH1: %DB[DIV HMI CFG\DB DIV CFG].DBX52.1
CH2: %DB[DIV HMI CFG\DB DIV CFG].DBX52.2
On the HMI can be changed on 2520 or on 2920 pages On the FC2101 ( FC Divider 1 CFG ) it is all the Setup for the DBs on the HMI :
L 2115
T "DB Divider 1 HMI".DBW_70
L 2100
T "DB Divider 1 HMI".DBW_72
L 2150
T "DB Divider 1 HMI".DBW_74
L 2170
T "DB Divider 1 HMI".DBW_76
L 2151
T "DB Divider 1 HMI".DBW_78
L 2171
T "DB Divider 1 HMI".DBW_80
L 2172
T "DB Divider 1 HMI".DBW_82
L 2155
T "DB Divider 1 HMI".DBW_84
L 2156
T "DB Divider 1 HMI".DBW_86
//************************************************************\\
// Configure the divider type
// 0 = Following divider
// 1 = Divider with only the Y axis and having a bottle lock
SET
R "DB Divider 1 CFG".CFG_HW_Div_Type
//************************************************************\\
CALL "COPY DBW"
Source_DB :=15
Source_WORD :=0
Dest_DB :="DB Divider 1 HMI".DBW_70
Dest_WORD :=0
n_WORD :=20
Ret_Val :=#RetVal
!
The Copy copies the Plant Name
On the Main page is set the DIV HMI CFG\DB DIV HMI=2110
The DB Divider 1 HMI
is the 2110 so from this DB the panel get all the other DBs
DIV HMI CFG\DB DIV CFG = %DB[DIV HMI CFG\DB DIV HMI].DBW72
DIV HMI CFG\DB DIV CFG = 2100