2.0 KiB
2.0 KiB
Tested setup:
Name | KT20120 | KT20210 | KT20260 | KT21020 |
---|---|---|---|---|
Range | 10 | 10s | 1s | 1s |
Time | 1,5 | 6 | 3 | 5 |
Function | B | A | A | F |
!Pasted image 20241121092514.png
!Pasted image 20241121093259.png
For the connection to the Marken IO-Box
!Pasted image 20241211160304.png
Vetromeccanica | MARKEN | Nr Image |
---|---|---|
XAC0 +D | EXT24in | 1 |
20310 | KA1 - (14) | 2 |
20310 | KA2 - (12) | 3 |
==modificato il 16/01/2025== Marken ha aggiornato i rele per i segnali.
!Pasted image 20250116151204.png
The CARTON REJECT SYSTEM from Vetromeccanica has two main logics:
- Full Table Alarm: If the B20210 (Table Full) is dark after the time on KT20210, the system goes into alarm and the KT21020 is activated. To reset this alarm, the operator needs to press the reset button on the cabinet. (S20230).
- Rejection: The Maken IOBox sends a pulse every time the Conex cameras do not detect the right print on the cases. The signals are in parallel from both cameras (connections 42 and 46). After we receive the pulse, KA20310 is activated, and so the stopper goes up. Then we wait until the box arrives at the B20260 photocell with the delay of the KT20260. The time on the KT20260 is only to filter the photocell and to allow the box to be stopped and be aligned to the stopper. After this KT20260 time delay has elapsed, the pusher piston is activated with YV20430.
- The air pressure used for the test was 4 bar.
Troubleshooting:
- Check the REERs (S20110 and S20120) on the pusher piston. These sensors are important to the functioning of the system and can prevent normal running.
- Check the emergency buttons and then reset on the SH14080 button.