### For conversion from SCL-500 to control Logix
***
Open the RSS project and then Save As ACD Select
![[Pasted image 20240227220304.png]]
### For the OP panel
***
1. Open FactoryTalk View Studio
1. New Application
2. Select resolution
3. Import..
![[Pasted image 20240227220644.png]]
https://www.youtube.com/watch?v=CaJQ9lVweYY
* RSLogix Project Migrator
- Convert 3 Rockwell SLC 505 PLC to Contrologix.
- Transport PLC QT1(keep existing 1734 remote I/O but convert from Device Net to ethernet communications)
- Robot 1 PLC QR1 (keep existing 1734 remote I/O but convert from Device Net to ethernet communications)
- Robot 2 PLC QR2 (keep existing 1734 remote I/O but convert from Device Net to ethernet communications) ( Program will be similar to Robot 1)
- Convert all Rockwell Device Net to Ethernet. Barilla will be responsible for all wiring changes. The following list is the device Net components:
- Power Flex 70 VFD drives.
- 1734 remote I/O
- Robots
- All Panel View stations are using ethernet communications and will remain the same.
- There are 4 electrical cabinets as follows:
- QT1 Main PLC cabinet for transport located near case packers.
- QT2 Remote cabinet for transport located in warehouse near robots 1 and 2.
- QR1 Robot 1 PLC
- QR2—Robot 2 PLC
- I will provide a link, so you receive a copy of the prints.
- QR1 and QT1 and QT2 are combined in a single file.
- QR2 is a separate file.
• Replace old Rockwell SLC 505s (3 total) with new Contrologix 1756-L82E or L83E
• Convert SLC programs (3 total) to Contrologix. Robot 1 and Robot 2 PLC programs are similar.
• Keep existing point I/O but replace Device Net communication module with Ethernet
• Replace all HIM with Touch Screen HIM 2711P-T10C22D9P
• Remove any Device net communication and replace with Ethernet
• Convert robots to Ethernet communication
• Replace all VFD drives with AB 525 series
• Provide Barilla with hardware parts list for conversion
• Increase SKU memory in PLC to minimum of 300
• Give possible suggestion for improvements to system
• List any possible software/firmware changes to Robots
• Provide a quote for conversion by February 2022
• Provide a timeline for conversion to determine downtime
• Update prints. Barilla will provide PDF copy of existing prints.