Cliente: Omega Packing
|
|
Destinazione: Mexico
|
|
Descrizione: Linea 7 Fàbrica de Jabòn la Corona
|
|
|
|
|
|
### Motors:
|
|
***
|
|
|
|
| | Motor | 0,55KW | 0,75 KW | Photocell | IO | m/min a 50hz | IP |
|
|
| :-: | ----- | :----: | ------- | :-------------: | :-------------------: | :----------: | --- |
|
|
| 1 | M231 | x | | B51110 | IO45440.0 | 16.8 | 131 |
|
|
| 2 | M232 | x | | B51120 | IO45440.1 | 16.2 | 132 |
|
|
| 3 | M233 | x | | B51130 | IO45440.2 | 16.8 | 133 |
|
|
| 4 | M234 | x | | B51140 | IO45440.3 | 16.8 | 134 |
|
|
| 5 | M235 | x | | B51150 | IO45440.4 | 16.8 | 135 |
|
|
| 6 | M236 | x | | B51160 | IO45440.5 | 16.8 | 136 |
|
|
| 7 | M237 | x | | B51170 | IO45440.6 | 16.2 | 137 |
|
|
| 8 | M238 | x | | B52110 | IO45441.0 | 16.2 | 138 |
|
|
| 9 | M239 | x | | B52120 / B52130 | IO45441.1 / IO45441.2 | 16.2 | 139 |
|
|
| | | | | | | | |
|
|
| 1 | M271 | | x | B53110 | IO45450.0 | 11.1 | 171 |
|
|
| 2 | M272 | | x | B53120 | IO45450.1 | 11.1 | 172 |
|
|
| 3 | M273 | x | | | | 11.0 | 173 |
|
|
| 4 | M274 | | x | | | 11.1 | 174 |
|
|
| 5 | M275 | | x | B53130 | | 11.1 | 175 |
|
|
| 6 | M276 | x | | | | 8.2 | 176 |
|
|
| 7 | M277 | | x | B53180 | | 11.1 | 177 |
|
|
| 8 | M278 | x | | | | 8.3 | 178 |
|
|
| 9 | M279 | | x | | | 11.0 | 179 |
|
|
| 10 | M280 | | x | B53140 | | 11.1 | 180 |
|
|
| 11 | M281 | | x | B53150 | | 11.1 | 181 |
|
|
| 12 | M282 | | x | B53160 | | 11.1 | 182 |
|
|
|
|
|
|
### IPs & Passwords
|
|
***
|
|
|
|
* IPs:
|
|
* PLC: 10.1.30.11
|
|
* HMI: 10.1.30.10
|
|
* PLC: 192.168.1.11
|
|
* IM 192.168.1.1
|
|
* Stratix: 192.168.1.12
|
|
* Inverters: 192.168.1.131 ... 182xx
|
|
|
|
* On HMI Users:
|
|
* Tec: 7777
|
|
* Manager: 8888
|
|
* Operator: 1111
|
|
* Superuser: 82549
|
|
|
|
* PanelView Plus Passwords:
|
|
* VNC: 100
|
|
* System: Vetromeccanica24
|
|
* Setup: Vetromeccanica24
|
|
|
|
* Web server 1734-AENTR/C: ( 10.1.30.12 )
|
|
* User: admin
|
|
* Password: password
|
|
|
|
|
|
### Sections
|
|
***
|
|
The PLC is divided in 2 sections as TTOP / BCC from motors M231 to M239 and PACK / PCC from M271 to M282.
|
|
|
|
For the synoptic the all the layout is divided on Left / Right.
|
|
|
|
![[Pasted image 20241009140921.png|775]]
|
|
|
|
![[Pasted image 20241014175842.png|775]]
|
|
|
|
|
|
### Flows
|
|
***
|
|
All the line has two selection of flows.
|
|
* In the TTOP area, you can select the FLOW to either M238 or M239. Based on this selection, the motors and the machines not involved in the flow will be disabled.
|
|
* The same for the Palletizing area on the M279, can be selected to manual Palletizing or to the M280 flow.
|
|
|
|
The flow logic work on the `P0_Common.R006_Flows` programs and force the selection of only one selection for each flow.
|
|
|
|
|
|
![[Pasted image 20241014174923.png]]
|
|
Then the motor logics used this flags to decide if the motor can run or not.
|
|
|
|
##### Data:
|
|
***
|
|
![[Pasted image 20241015114012.png|1125]]
|
|
|
|
### Motor Logic:
|
|
***
|
|
|
|
Every motor uses the same basic logic, copying on the Motor[1].I.Pht1 the photocell or photocells used on the motor.
|
|
|
|
R201_Input:
|
|
```pascal
|
|
// Ingressi Motore M23160 - Omega
|
|
if Motor[1].Presence then
|
|
CPS(M23160:I,Motor[1].Drive.Telegram.I,1);
|
|
Motor[1].I.CircuitBreaker:=IO45420.0;
|
|
Motor[1].I.Thermic:=1;
|
|
Motor[1].I.Pht1:=IO45440.0;// 0 Product presence - 1 Empty
|
|
Motor[1].I.Pht2:=KI_NotPresent;
|
|
...
|
|
Motor[1].I.PEW:=KPEW_NotPresent;
|
|
end_if;
|
|
```
|
|
|
|
![[Pasted image 20241014175316.png]]
|
|
|
|
Then this photocells are filtered and used on the Enable
|
|
|
|
![[Pasted image 20241014175450.png]]
|
|
|
|
![[Pasted image 20241014175509.png]]
|
|
|
|
Then the timer output is used to run the motor.
|
|
|
|
|
|
### To save Data on the Recipe
|
|
***
|
|
|
|
![[Pasted image 20241009141036.png]]
|
|
|
|
* With (4) the data is copied from Motors to PLC_Recipe
|
|
|
|
![[Pasted image 20241009141416.png]]
|
|
|
|
* With (1) the data is copied from PLC_Recipe to HMI_Recipe
|
|
* With (2) the data is copied from HMI_Recipe to Recipe_DataStore
|
|
|
|
|
|
### Signals with other machines:
|
|
***
|
|
|
|
On the P0_Common.R011_ExtMachines there is the main configuration of the tags used for the digital and analog communications.
|
|
|
|
```pascal
|
|
//ABILITAZIONI MACCHINE
|
|
ExtMachine[KBlower].Presence :=0;
|
|
ExtMachine[KUnscrambler].Presence :=0;
|
|
ExtMachine[KFiller].Presence :=0;
|
|
ExtMachine[KLabeller].Presence :=1;
|
|
ExtMachine[KSleever].Presence :=1;
|
|
ExtMachine[KShrinkWrapper].Presence :=1;
|
|
ExtMachine[KPackInsert].Presence :=0;
|
|
ExtMachine[KPallettizer].Presence :=1;
|
|
ExtMachine[KPastorizer].Presence :=0;
|
|
ExtMachine[KCluster].Presence :=0;
|
|
ExtMachine[KDepal].Presence :=0;
|
|
ExtMachine[KBalance].Presence :=1;
|
|
```
|
|
|
|
|
|
![[Pasted image 20241015114419.png]]
|
|
![[Pasted image 20241015114433.png]]
|
|
|
|
The HMI Texts are:
|
|
|
|
![[Pasted image 20241015114507.png]]
|
|
![[Pasted image 20241015114526.png]]
|
|
|
|
|
|
For the especial cases of signals that are generated on different Px can be used the CommonOutputs tags
|
|
|
|
##### P0_Common.R099_Output:
|
|
```pascal
|
|
//uscite ciclo Comune
|
|
IO45610.3 := CommonOutputs.0 OR CommonOutputs.1;
|
|
```
|
|
|
|
![[Pasted image 20241015115154.png]]
|
|
|
|
|
|
### PB71 / PB72 - Manual Palletizing
|
|
***
|
|
|
|
![[Pasted image 20241015115326.png|550]]
|
|
|
|
#### For the manual palletizing the logic works like this:
|
|
***
|
|
|
|
| PB71.Manual | PB71.Auto | PB71.Stop | PB72.Manual | PB72.Auto | PB72.Stop | Function |
|
|
| :---------: | :-------: | :-------: | :---------: | :-------: | :-------: | :------------------------: |
|
|
| | | x | any | any | any | -> Stop |
|
|
| any | any | any | | | x | -> Stop |
|
|
| | x | | x | | | -> Manual run |
|
|
| x | | | | x | | -> Manual run |
|
|
| | x | | | x | | -> Auto run with photocell |
|
|
* So any stop position stops the M279
|
|
* To run in manual the other key must be in auto o manual
|
|
* To run in auto both keys must be in auto
|
|
|