#### Brake without DynaStop option:
![[Pasted image 20241107151714.png]]
#### DynaStop enabled motors:
***
![[Imagen de WhatsApp 2024-11-07 a las 14.49.30_547095fc.jpg|625]]
# Activating the function
https://download.sew-eurodrive.com/download/html/27802922/en-EN/2508655041141416666507.html
##### Danger due to falling loads.
##### Severe or fatal injuries.
- Do **not** use the "Release brake/deactivate DynaStop® with FCB01" function in lifting devices or applications with loads that might potentially fall down.
- Inhibit the function via the following steps:
- Deactivate the function of DIP switch S1/2 using parameter _Deactivation_ = **"1"** (Path: _Functions > Inputs/Outputs > Basic device > DIP switch functions > Release brake/deactivate DynaStop_® _deactivate with FCB01_  _Enable_)
- Inhibit the function using the parameter _Release brake/deactivate DynaStop® with FCB 01 enable_ = **"0"** (path: _Functions_ > _Drive functions_ > _FCB 01 Output stage inhibit_).
In case the output stage is inhibited by a control signal (digital input or process data bit), the DynaStop® function can be deactivated using the function "Release brake/deactivate DynaStop® with FCB01". For example, this allows to move loads freely using a horizontal conveyor.
Now make the following settings:
1. **Enabling the function**:
- **Via DIP switch S1/2**
you switch the DIP switch S1/2 "Release brake/deactivate DynaStop® with FCB01 enable" = ON.
- **Via the parameter setting**
you deactivate DIP switch S1/2 by setting the parameter _Deactivation_ = **"1"**. (Path: _Functions_ > _Input/outputs_ > _Basic device_ > _DIP switch functions_ > _Release brake/deactivate DynaStop_® _with FCB01 release)_
Release the function "Release brake/deactivate DynaStop® for FCB01 enable" by setting the parameter _Release brake/deactivate DynaStop_® _for FCB01 release_ = **"1"** [1]. (Path: _Functions_ > _Drive functions_ > _FCB 01 Output stage inhibit_)
![](https://download.sew-eurodrive.com/download/html/27802922/Images/png/18014420484359179__en__Web.png)
![](https://download.sew-eurodrive.com/download/html/27802922/assets/img/icons/x_white.png)
5. **Configuring the control signal**:
- **Control via digital input**
Assign a digital input with the function "Release brake/deactivate DynaStop® with FCB01" [2].
![](https://download.sew-eurodrive.com/download/html/27802922/Images/png/18014420484362123__en__Web.png)
![](https://download.sew-eurodrive.com/download/html/27802922/assets/img/icons/x_white.png)
- **Control via process data bit** (not available in DBC designs)
Assign a process output bit with the function "Release brake/deactivate DynaStop® with FCB01" [3].
![](https://download.sew-eurodrive.com/download/html/27802922/Images/png/27021619739106059__en__Web.png)
![](https://download.sew-eurodrive.com/download/html/27802922/assets/img/icons/x_white.png)
The set control signal can be used to deactivate DynaStop® when the function block FCB01 is active.
### On the manual
![[Pasted image 20240925131406.png]]
### To be tested
***
![[Pasted image 20240925131415.png]]